Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Atomic absorption spectroscopy
(section)
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
== Instrumentation == [[File:AASBLOCK.JPG|thumb|250px|Atomic absorption spectrometer block diagram]] In order to analyze a sample for its atomic constituents, it has to be atomized. The atomizers most commonly used nowadays are flames and electrothermal ([[graphite]] tube) atomizers. The atoms should then be irradiated by optical radiation, and the radiation source could be an element-specific line radiation source or a continuum radiation source. The radiation then passes through a [[monochromator]] in order to separate the element-specific radiation from any other radiation emitted by the radiation source, which is finally measured by a detector. === Atomizers === The atomizers most commonly used nowadays are spectroscopic flames and electrothermal atomizers. Other atomizers, such as glow-discharge atomization, hydride atomization, or cold-vapor atomization, might be used for special purposes. ==== Flame atomizers ==== The oldest and most commonly used atomizers in AAS are flames, principally the air-acetylene flame with a temperature of about 2300 °C and the nitrous oxide<ref name="Koirtyohann1991" /> system (N<sub>2</sub>O)-acetylene flame with a temperature of about 2700 °C. The latter flame, in addition, offers a more reducing environment, being ideally suited for analytes with a high affinity to oxygen. [[File:FP8800GM.jpg|thumb|A laboratory flame photometer that uses a propane operated flame atomizer]] Liquid or dissolved samples are typically used with flame atomizers. The sample solution is aspirated by a pneumatic [[analytical nebulizer]], transformed into an [[aerosol]], which is introduced into a spray chamber, where it is mixed with the flame gases and conditioned in a way that only the finest aerosol droplets (< 10 μm) enter the flame. This conditioning process reduces interference, but only about 5% of the aerosolized solution reaches the flame because of it. On top of the spray chamber is a burner head that produces a flame that is laterally long (usually 5–10 cm) and only a few mm deep. The radiation beam passes through this flame at its longest axis, and the flame gas flow-rates may be adjusted to produce the highest concentration of free atoms. The burner height may also be adjusted so that the radiation beam passes through the zone of highest atom cloud density in the flame, resulting in the highest sensitivity. The processes in a flame include the stages of desolvation (drying) in which the solvent is evaporated and the dry sample nano-particles remain, [[vaporization]] (transfer to the gaseous phase) in which the solid particles are converted into gaseous molecule, atomization in which the molecules are dissociated into free atoms, and [[ionization]] where (depending on the ionization potential of the analyte atoms and the energy available in a particular flame) atoms may be in part converted to gaseous ions. Each of these stages includes the risk of interference in case the degree of phase transfer is different for the analyte in the calibration standard and in the sample. Ionization is generally undesirable, as it reduces the number of atoms that are available for measurement, i.e., the sensitivity. In flame AAS, a steady-state signal is generated during the time period when the sample is aspirated. This technique is typically used for determinations in the mg L<sup>−1</sup> range and may be extended down to a few μg L<sup>−1</sup> for some elements. ==== Electrothermal atomizers ==== [[File:GFAA method development-courtesy jball-Analytik Jena USA.JPG|thumb|right |400 px|GFAA method development]] [[File:Lvov furnace 2.JPG|thumb|right|Graphite tube]] [[Graphite furnace atomic absorption|Electrothermal AAS]] (ET AAS) using graphite tube atomizers was pioneered by Boris V. L'vov at the [[Saint Petersburg Polytechnical University|Saint Petersburg Polytechnical Institute]], Russia,<ref>{{cite journal |last1=L'vov |first1=Boris |title=Recent advances in absolute analysis by graphite furnace atomic absorption spectrometry |date=1990 |journal=Spectrochimica Acta Part B: Atomic Spectroscopy |doi=10.1016/0584-8547(90)80046-L |volume=45 |issue=7 |pages=633–655 |url=https://pubs.rsc.org/en/Content/ArticleLanding/1988/JA/JA9880300009|bibcode=1990AcSpB..45..633L |url-access=subscription }}</ref> since the late 1950s, and investigated in parallel by Hans Massmann at the Institute of Spectrochemistry and Applied Spectroscopy (ISAS) in Dortmund, Germany.<ref>{{cite web|title=Analytical Methods for Graphite Tube Atomizers|url=http://hpst.cz/sites/default/files/attachments/gta-analytical-methods-0848.pdf |archive-url=https://ghostarchive.org/archive/20221009/http://hpst.cz/sites/default/files/attachments/gta-analytical-methods-0848.pdf |archive-date=2022-10-09 |url-status=live|website=agilent.com|publisher=Agilent Technologies}}</ref> Although a wide variety of graphite tube designs have been used over the years, the dimensions nowadays are typically 20–25 mm in length and 5–6 mm inner diameter. With this technique liquid/dissolved, solid, and gaseous samples may be analyzed directly. A measured volume (typically 10–50 μL) or a weighed mass (typically around 1 mg) of a solid sample are introduced into the graphite tube and subject to a temperature program. This typically consists of stages, such as drying – the solvent is evaporated; [[pyrolysis]] – the majority of the matrix constituents are removed; atomization – the analyte element is released to the gaseous phase; and cleaning – eventual residues in the graphite tube are removed at high temperature.<ref>{{Cite web|title=Atomic Spectroscopy - GF-AAS|url=https://sites.chem.utoronto.ca/chemistry/coursenotes/analsci/atomic/gfaas.html#:~:text=Graphite%20furnace%20atomization%20(also%20known,inside%20a%20hollow%20graphite%20tube.|access-date=2021-03-08|website=sites.chem.utoronto.ca}}</ref> The graphite tubes are heated via their ohmic resistance using a low-voltage high-current power supply; the temperature in the individual stages can be controlled very closely, and temperature ramps between the individual stages facilitate the separation of sample components. Tubes may be heated transversely or longitudinally, where the former ones have the advantage of a more homogeneous temperature distribution over their length. The so-called stabilized temperature platform furnace (STPF) concept, proposed by Walter Slavin, based on research of Boris L'vov, makes ET AAS essentially free from interference.{{citation needed|date=July 2014}} The major components of this concept are atomization of the sample from a graphite platform inserted into the graphite tube (L'vov platform) instead of from the tube wall in order to delay atomization until the gas phase in the atomizer has reached a stable temperature; use of a chemical modifier in order to stabilize the analyte to a pyrolysis temperature that is sufficient to remove the majority of the matrix components; and integration of the absorbance over the time of the transient absorption signal instead of using peak height absorbance for quantification. In ET AAS, a transient signal is generated, the area of which is directly proportional to the mass of analyte (not its concentration) introduced into the graphite tube. This technique has the advantage that any kind of sample, solid, liquid, or gaseous, can be analyzed directly. Its sensitivity is 2–3 orders of magnitude higher than that of flame AAS, so that determinations in the low μg L<sup>−1</sup> range (for a typical sample volume of 20 μL) and ng g<sup>−1</sup> range (for a typical sample mass of 1 mg) can be carried out. It shows a very high degree of freedom from interferences, so that ET AAS might be considered the most robust technique available nowadays for the determination of trace elements in complex matrices.{{citation needed|date=July 2014}} ====Specialized atomization techniques==== While flame and electrothermal vaporizers are the most common atomization techniques, several other atomization methods are utilized for specialized use.<ref>{{Cite web|url=https://chem.libretexts.org/Textbook_Maps/Analytical_Chemistry_Textbook_Maps/Map%3A_Analytical_Chemistry_2.0_(Harvey)/10_Spectroscopic_Methods/10.4%3A_Atomic_Absorption_Spectroscopy|title=Atomic Absorption Spectroscopy|last=Harvey|first=David|date=2016-05-25|website=chem.libretexts.org|access-date=2017-10-06|archive-url=https://web.archive.org/web/20171006113153/https://chem.libretexts.org/Textbook_Maps/Analytical_Chemistry_Textbook_Maps/Map%3A_Analytical_Chemistry_2.0_(Harvey)/10_Spectroscopic_Methods/10.4%3A_Atomic_Absorption_Spectroscopy|archive-date=2017-10-06|url-status=dead}}</ref><ref>{{Cite web|url=http://blogs.maryville.edu/aas/atomization-source/|title=Sample Atomization – Atomic Absorption Spectroscopy Learning Module|website=blogs.maryville.edu|language=en-US|access-date=2017-11-02}}</ref> =====Glow-discharge atomization===== A glow-discharge device (GD) serves as a versatile source, as it can simultaneously introduce and atomize the sample. The [[glow discharge]] occurs in a low-pressure argon gas atmosphere between 1 and 10 torr. In this atmosphere lies a pair of electrodes applying a [[Direct Current|DC]] voltage of 250 to 1000 V to break down the argon gas into positively charged ions and electrons. These ions, under the influence of the electric field, are accelerated into the cathode surface containing the sample, bombarding the sample and causing neutral sample atom ejection through the process known as [[sputtering]]. The atomic vapor produced by this discharge is composed of ions, ground state atoms, and a fraction of excited atoms. When the excited atoms relax back into their ground state, a low-intensity glow is emitted, giving the technique its name. The requirement for samples of glow discharge atomizers is that they are electrical conductors. Consequently, atomizers are most commonly used in the analysis of metals and other conducting samples. However, with proper modifications, it can be utilized to analyze liquid samples as well as nonconducting materials by mixing them with a conductor (e.g. graphite). =====Hydride atomization===== Hydride generation techniques are specialized in solutions of specific elements. The technique provides a means of introducing samples containing arsenic, antimony, selenium, bismuth, and lead into an atomizer in the gas phase. With these elements, hydride atomization enhances detection limits by a factor of 10 to 100 compared to alternative methods. Hydride generation occurs by adding an acidified aqueous solution of the sample to a 1% aqueous solution of sodium borohydride, all of which is contained in a glass vessel. The volatile hydride generated by the reaction that occurs is swept into the atomization chamber by an inert gas, where it undergoes decomposition. This process forms an atomized form of the analyte, which can then be measured by absorption or emission spectrometry. =====Cold-vapor atomization===== The cold-vapor technique is an atomization method limited only for the determination of mercury due to it being the only metallic element to have a large vapor pressure at ambient temperature.{{citation needed|date=March 2016}} Because of this, it has an important use in determining organic mercury compounds in samples and their distribution in the environment. The method initiates by converting mercury into Hg<sup>2+</sup> by oxidation from nitric and sulfuric acids, followed by a reduction of Hg<sup>2+</sup> with [[SnCl2|tin(II) chloride]]. The mercury is then swept into a long-pass absorption tube by bubbling a stream of inert gas through the reaction mixture. The concentration is determined by measuring the absorbance of this gas at 253.7 nm. Detection limits for this technique are in the parts-per-billion range, making it an excellent mercury detection atomization method. === Radiation sources === We have to distinguish between line source AAS (LS AAS) and continuum source AAS (CS AAS). In classical LS AAS, as it has been proposed by Alan Walsh,<ref>{{cite book|last1=Walsh|first1=Alan|last2=Becker-Ross|first2=Helmut|last3=Florek|first3=Stefan|last4=Heitmann|first4=Uwe|title=High-Resolution Continuum Source AAS|date=19 January 2006|publisher=Wiley-VCH Verlag GmbH & Co. KGaA|location=Weinheim|isbn=9783527307364|page=2}}</ref> the high spectral resolution required for AAS measurements is provided by the radiation source itself that emits the spectrum of the analyte in the form of lines that are narrower than the absorption lines. Continuum sources, such as deuterium lamps, are only used for background correction purposes. The advantage of this technique is that only a medium-resolution monochromator is necessary for measuring AAS; however, it has the disadvantage that usually a separate lamp is required for each element that has to be determined. In CS AAS, in contrast, a single lamp, emitting a continuum spectrum over the entire spectral range of interest is used for all elements. Obviously, a high-resolution monochromator is required for this technique, as will be discussed later. [[File:Mehrelement-Hohlkathodenlampe für bessere UV-Lichtdurchlässigkeit mit eingelassenem Quarzfenster.jpg|thumb|250px|Hollow cathode lamp (HCL)]] ==== Hollow cathode lamps ==== [[Hollow cathode lamps]] (HCL) are the most common radiation source in LS AAS.{{citation needed|date=March 2016}} Inside the sealed lamp, filled with argon or neon gas at low pressure, is a cylindrical metal cathode containing the element of interest and an anode. A high voltage is applied across the anode and cathode, resulting in an ionization of the fill gas. The gas ions are accelerated towards the cathode and, upon impact on the cathode, sputter cathode material that is excited in the glow discharge to emit the radiation of the sputtered material, i.e., the element of interest. In the majority of cases single element lamps are used, where the cathode is pressed out of predominantly compounds of the target element. Multi-element lamps are available with combinations of compounds of the target elements pressed in the cathode. Multi element lamps produce slightly less sensitivity than single element lamps and the combinations of elements have to be selected carefully to avoid spectral interferences. Most multi-element lamps combine a handful of elements, e.g.: 2 - 8. Atomic Absorption Spectrometers can feature as few as 1-2 hollow cathode lamp positions or in automated multi-element spectrometers, a 8-12 lamp positions may be typically available. ==== Electrodeless discharge lamps ==== [[Electrodeless lamp|Electrodeless discharge lamps]] (EDL) contain a small quantity of the analyte as a metal or a salt in a quartz bulb together with an inert gas, typically argon gas, at low pressure. The bulb is inserted into a coil that is generating an electromagnetic radio frequency field, resulting in a low-pressure inductively coupled discharge in the lamp. The emission from an EDL is higher than that from an HCL, and the line width is generally narrower, but EDLs need a separate power supply and might need a longer time to stabilize. ==== Deuterium lamps ==== [[Deuterium arc lamp|Deuterium HCL]] or even hydrogen HCL and deuterium discharge lamps are used in LS AAS for background correction purposes.<ref>{{cite web|last1=Rakshit|first1=Amitava|title=Basics of Laboratory Safety: Common laboratory rules and regulations|url=http://www.intecol.net/pages/002_personal.php?table=blog&tb_kind=Research&id=Amitava&vvt=aa&bidx=134710|website=The International Association for Ecology|publisher=Intecol|access-date=26 September 2016|archive-url=https://web.archive.org/web/20160927115008/http://www.intecol.net/pages/002_personal.php?table=blog&tb_kind=Research&id=Amitava&vvt=aa&bidx=134710|archive-date=27 September 2016|url-status=dead}}</ref> The radiation intensity emitted by these lamps decreases significantly with increasing wavelength, so that they can be only used in the wavelength range between 190 and about 320 nm. [[File:Continuous radiation source.jpg|thumb|250px|Xenon lamp as a continuous radiation source]] ==== Continuum sources ==== When a continuum radiation source is used for AAS, it is necessary to use a high-resolution monochromator, as will be discussed later. In addition, it is necessary that the lamp emits radiation of intensity at least an order of magnitude above that of a typical HCL over the entire wavelength range from 190 nm to 900 nm. A special [[Xenon arc lamp|high-pressure xenon short arc lamp]], operating in a hot-spot mode has been developed to fulfill these requirements. === Spectrometer === As already pointed out above, there is a difference between medium-resolution spectrometers that are used for LS AAS and high-resolution spectrometers that are designed for CS AAS. The spectrometer includes the spectral sorting device (monochromator) and the detector. ==== Spectrometers for LS AAS ==== In LS AAS, the high resolution that is required for the measurement of atomic absorption is provided by the narrow line emission of the radiation source, and the monochromator simply has to resolve the analytical line from other radiation emitted by the lamp.{{citation needed|date=March 2016}} This can usually be accomplished with a band pass between 0.2 and 2 nm, i.e., a medium-resolution monochromator. Another feature to make LS AAS element-specific is modulation of the primary radiation and the use of a selective amplifier that is tuned to the same modulation frequency, as already postulated by Alan Walsh. This way any (unmodulated) radiation emitted for example by the atomizer can be excluded, which is imperative for LS AAS. Simple monochromators of the Littrow or (better) the Czerny-Turner design are typically used for LS AAS. Photomultiplier tubes are the most frequently used detectors in LS AAS, although solid state detectors might be preferred because of their better [[signal-to-noise ratio]]. ==== Spectrometers for CS AAS ==== When a continuum radiation source is used for AAS measurement it is indispensable to work with a high-resolution monochromator. The resolution has to be equal to or better than the half-width of an atomic absorption line (about 2 pm) in order to avoid losses of sensitivity and linearity of the calibration graph. The research with high-resolution (HR) CS AAS was pioneered by the groups of O'Haver and Harnly in the US, who also developed the (up until now) only simultaneous multi-element spectrometer for this technique. The breakthrough, however, came when the group of Becker-Ross in Berlin, Germany, built a spectrometer entirely designed for HR-CS AAS. The first commercial equipment for HR-CS AAS was introduced by [[Analytik Jena]] (Jena, Germany) at the beginning of the 21st century, based on the design proposed by Becker-Ross and Florek. These spectrometers use a compact double monochromator with a prism pre-monochromator and an echelle grating monochromator for high resolution. A linear [[charge-coupled device]] (CCD) array with 200 pixels is used as the detector. The second monochromator does not have an exit slit; hence the spectral environment at both sides of the analytical line becomes visible at high resolution. As typically only 3–5 pixels are used to measure the atomic absorption, the other pixels are available for correction purposes. One of these corrections is that for lamp flicker noise, which is independent of wavelength, resulting in measurements with very low noise level; other corrections are those for background absorption, as will be discussed later.
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)