Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Canadian Light Source
(section)
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
===Beamlines=== [[File:Schematic-representation-of-the-major-components-of-the-Canadian-Light-Source-The-29.jpg|center|thumb|500x500px|Layout of beamlines at the Canadian Light Source synchrotron]] {| class="wikitable" style="width:100%;" |- ! ID ! Name ! Port assigned<ref name="beamlines">{{cite web | url= http://www.lightsource.ca/experimental/ | title= Beamlines | accessdate= 23 July 2012 | archive-date= 27 July 2012 | archive-url= https://web.archive.org/web/20120727235743/http://www.lightsource.ca/experimental/ | url-status= dead }}</ref> ! Phase ! Source ! Energy range (keV unless stated) ! Usage |- | BioXAS | Life science beamline for [[X-ray absorption spectroscopy]] | | 3 | Wiggler,<br />in-vacuum undulator<ref name="IDdev" /> | | Life- and environmental science research using X-ray absorption spectroscopy and imaging.<ref name="progress" /> |- | BMIT-BM | [[Medical imaging|Biomedical Imaging]] and [[radiation therapy|Therapy]] | 05B1-1 | 2 | Bending Magnet | 8β40 | Imaging small to medium-sized animals (up to sheep size)<ref name="BMIT1">{{Cite journal |last1=Wysokinski |first1=Tomasz W. |last2=Chapman |first2=Dean |last3=Adams |first3=Gregg |last4=Renier |first4=Michel |last5=Suortti |first5=Pekka |last6=Thomlinson |first6=William |year=2007 |title=Beamlines of the biomedical imaging and therapy facility at the Canadian light sourceβPart 1 |journal=Nuclear Instruments and Methods in Physics Research A |volume=582 |issue=1 |pages=73β76 |doi=10.1016/j.nima.2007.08.087 |bibcode = 2007NIMPA.582...73W |hdl=10138/162090 |url=https://helda.helsinki.fi/bitstream/10138/162090/1/jpconf13_425_072013.pdf|hdl-access=free}}</ref> |- | BMIT-ID | Biomedical Imaging and Therapy | 05ID-2 | 2 | Wiggler | 20β100 | Higher energy and larger animal capabilities than possible on the BM line<ref name="progress">{{cite web | url=http://www.cap.ca/sites/cap.ca/files/article/588/July07-offprint-CLS.pdf | title=Progress at Canada's national synchrotron facility: the Canadian Light Source | year=2007 | accessdate=23 July 2012 | archive-date=2 May 2014 | archive-url=https://web.archive.org/web/20140502013312/http://www.cap.ca/sites/cap.ca/files/article/588/July07-offprint-CLS.pdf | url-status=dead }}</ref> |- | BXDS | Brockhouse [[X-ray scattering techniques|X-ray diffraction and scattering]] sector | | 3 | In-vacuum undulator and wiggler | | Resonant- and non-resonant, small and wide angle X-ray scattering. X-ray diffraction.<ref name="progress" /> |- |CMCF-ID |Canadian [[X-ray crystallography|Macromolecular crystallography]] Facility |08ID-1 |1 |in-vacuum undulator |6.5β18 |Macromolecular crystallography beamline suitable for studying small crystals and crystals with large unit cells.<ref name="Prime">{{Cite journal |last1=Grochulski |first1=P. |last2=Fodje |first2=M. N. |last3=Gorin |first3=J. |last4=Labiuk |first4=S. L. |last5=Berg |first5=R. |year=2011 |title=Beamline 08ID-1, the prime beamline of the Canadian Macromolecular Crystallography Facility |journal=Journal of Synchrotron Radiation |volume=18 |issue=4 |pages=681β684 |doi=10.1107/S0909049511019431 |pmid=21685687 |doi-access=free}}</ref> |- |CMCF-BM |Canadian Macromolecular Crystallography Facility |08B1-1 |2 |Bending Magnet |4β18 |High throughput macromolecular crystallography.<ref name="progress" /> |- | Far IR | High Resolution Far [[Infrared spectroscopy]] | 02B1-1 | 1 | Bending Magnet | 10β1000 cm<sup>β1</sup> | Ultrahigh resolution infrared spectroscopy of gas-phase molecules<ref name="IR">{{Cite journal |last1=May |first1=Tim |last2=Appadoo |first2=Dominique |last3=Ellis |first3=Thomas |last4=Reininger |first4=Ruben |year=2006 |title=Infrared Beamlines at the Canadian Light Source |journal=AIP Conference Proceedings |volume=882 |pages=579β582 |doi=10.1063/1.2436127 }}</ref> |- | HXMA | Hard X-ray micro-Analysis | 06ID-1 | 1 | Wiggler | 5β40 | [[X-ray absorption fine structure]], X-ray [[microprobe]], X-ray diffraction<ref name="XAFS">{{Cite journal |last1=Jiang |first1=D. T. |last2=Chen |first2=N. |last3=Zhang |first3=L. |last4=Malgorzata |first4=K. |last5=Wright |first5=G. |last6=Igarashi |first6=R. |last7=Beuregard |first7=D. |last8=Kirkham |first8=M. |last9=McKibben |first9=M. |year=2006 |title=XAFS at the Canadian Light Source |journal=AIP Conference Proceedings |volume=882 |pages=893β895 |doi=10.1063/1.2644695 |s2cid=136888175 }}</ref> |- | IDEAS | Educational beamline | | | Bending Magnet | | Purpose-built educational beamline<ref name="IDEAS">{{cite web | url= http://www.lightsource.ca/media/media_release_20120528.php | archive-url= https://archive.today/20130115120608/http://www.lightsource.ca/media/media_release_20120528.php | url-status= dead | archive-date= 15 January 2013 | title= Synchrotron hub of high school student research | date= 28 May 2012 | format= PDF | accessdate= 22 July 2012 }}</ref> |- | Mid IR | [http://midir.lightsource.ca/ Mid IR Spectromicroscopy] | 01B1-1 | 1 | Bending Magnet | 560β6000 cm<sup>β1</sup> | Infrared spectromicroscopic imaging at diffraction-limited spatial resolution, and [[photoacoustic spectroscopy]]<ref name="MidIR">{{Cite journal |last1=May |first1=Tim |last2=Ellis |first2=Thomas |last3=Reininger |first3=Ruben |year=2007 |title=Mid-infrared spectromicroscopy beamline at the Canadian Light Source |journal=Nuclear Instruments and Methods in Physics Research A |volume=582 |issue=1 |pages=111β113 |doi=10.1016/j.nima.2007.08.074 |bibcode = 2007NIMPA.582..111M }}</ref> |- | OSR | Optical Synchrotron Radiation | 02B1-2 | 1 | Bending Magnet | | Accelerator beam diagnostic beamline operating in the visible range.<ref name="OSR">{{Cite journal |last1=Bergstrom |first1=John C. |last2=Vogt |first2=Johannes M. |year=2006 |title=The optical diagnostic beamline at the Canadian Light Source |journal=Nuclear Instruments and Methods in Physics Research A |volume=562 |issue=1 |pages=495β512 |doi=10.1016/j.nima.2006.02.200 |bibcode = 2006NIMPA.562..495B }}</ref> |- | QMSC | Quantum Materials Spectroscopy Centre | | 3 | Double EPU<ref name="IDdev" /> | | Spin- and angle-resolved [[photoemission spectroscopy]].<ref name="progress" /> |- |REIXS |Resonant Elastic and Inelastic X-ray Scattering |10ID-2 |2 |EPU |80β2000 eV |[[Soft X-ray emission spectroscopy]] and resonant soft [[X-ray scattering techniques|X-ray scattering]].<ref name="progress"/> |- |SGM |High Resolution Spherical Grating Monochromator |11ID-1 |1 |EPU<ref name=":0" /> |240β2000 eV |X-ray absorption spectroscopy, X-ray photoemission spectroscopy. Interchangeable endstations, allows use of non-[[ultra-high vacuum|UHV]]-compatible samples<ref name="Dragon">{{Cite journal |last1=Regier |first1=T |last2=Krochak |first2=J |last3=Sham |first3=T. K. |last4=Hu |first4=Y. F. |last5=Thompson |first5=J. |last6=Blyth |first6=R. I. R. |year=2007 |title=Performance and capabilities of the CanadianDragon: The SGM beamline at the Canadian Light Source |journal=Nuclear Instruments and Methods in Physics Research A |volume=582 |issue=1 |pages=93β95 |doi=10.1016/j.nima.2007.08.071 |bibcode = 2007NIMPA.582...93R }}</ref> |- |SM |Soft X-ray Spectromicroscopy |10ID-1 |1 |EPU |100β2000 eV |Scanning transmission [[X-ray microscope|X-ray microscopy]], [[Photoemission electron microscopy]].<ref name="SM">{{Cite journal |last1=Kaznatcheev |first1=K. V. |last2=Karunakaran |first2=Ch. |last3=Lanke |first3=U. D. |last4=Urquhart |first4=S. G. |last5=Obst |first5=M. |last6=Hitchcock |first6=A. P. |year=2007 |title=Soft X-ray spectromicroscopy beamline at the CLS: Commissioning results |journal=Nuclear Instruments and Methods in Physics Research A |volume=582 |issue=1 |pages=96β99 |doi=10.1016/j.nima.2007.08.083 |bibcode = 2007NIMPA.582...96K }}</ref> |- |SXRMB |Soft X-ray Microcharacterization Beamline |06B1-1 |2 | Bending Magnet |1.7β10 |X-ray absorption fine structure, X-ray microprobe.<ref name="SXR">{{Cite journal |last1=Hu |first1=Y. F. |last2=Coulthard |first2=I. |last3=Chevrier |first3=D. |last4=Wright |first4=Glen |last5=Igarashi |first5=R. |last6=Sitnikov |first6=A. |last7=Yates |first7=B. W. |last8=Hallin |first8=E. |last9=Sham |first9=T. K. |last10=Reininger |first10=R. |last11=Garrett |first11=R. |last12=Gentle |first12=I. |last13=Nugent |first13=K. |last14=Wilkins |first14=S. |year=2009 |title=Preliminary Commissioning and Performance of the Soft X-ray Micro-characterization Beamline at the Canadian Light Source |journal=AIP Conference Proceedings |volume=1234 |pages=343β346 |doi=10.1063/1.3463208 }}</ref> |- | SyLMAND | Synchrotron Laboratory for Micro And Nano Devices |05B2-1 | 2 | Bending Magnet | 1β15 | Deep [[X-ray lithography]] with large area format<ref name="SyL">{{Cite journal |last1=Achenbach |first1=Sven |last2=Subramanian |first2=Venkat |last3=Klymyshyn |first3=David |last4=Wells |first4=Garth |year=2010 |title=Synchrotron laboratory for micro and nano devices: facility concept and design |journal=Microsystem Technologies |volume=16 |issue=8β9 |pages=1293β1298 |doi=10.1007/s00542-010-1071-3 |bibcode=2010MiTec..16.1293A |s2cid=111276622 }}</ref> |- |VESPERS |Very Sensitive Elemental and Structural Probe Employing Radiation from a Synchrotron |07B2-1 | 2 |Bending Magnet | 6β30 | Hard X-ray microprobe using X-ray diffraction and [[X-ray fluorescence]]. X-ray absorption spectroscopy.<ref name="VESPERS">{{Cite journal |last1=Feng |first1=Renfei |last2=Dolton |first2=Wade |last3=Igarashi |first3=Ru |last4=Wright |first4=Glen |last5=Bradford |first5=Morgan |last6=McIntyre |first6=Stewart |last7=Garrett |first7=R. |last8=Gentle |first8=I. |last9=Nugent |first9=K. |last10=Wilkins |first10=S. |year=2009 |title=Commissioning of the VESPERS Beamline at the Canadian Light Source |journal=AIP Conference Proceedings |volume=1234 |pages=315β318 |doi=10.1063/1.3463199 }}</ref> |- |VLS-PGM |Variable Line Spacing Plane Grating Monochromator |11ID-2 |1 |EPU<ref name=":0">{{Cite journal |last1=Baribeau |first1=Cameron |last2=Pedersen |first2=Tor |last3=Sigrist |first3=Michael |date=2019 |others=Boland Mark (Ed.), Tanaka Hitoshi (Ed.), Button David (Ed.), Dowd Rohan (Ed.), Schaa, Volker RW (Ed.), Tan Eugene (Ed.) |title=Virtual Shimming and Magnetic Measurements of two Long Period APPLE-II Undulators at the Canadian Light Source |url=http://jacow.org/ipac2019/doi/JACoW-IPAC2019-TUPRB003.html |journal=Proceedings of the 10th Int. Particle Accelerator Conf. |language=en |volume=IPAC2019 |pages=4 pages, 0.825 MB |doi=10.18429/JACOW-IPAC2019-TUPRB003}}</ref> |5.5β250 eV |High resolution X-ray Absorption Spectroscopy<ref name="PGM">{{Cite journal |last1=Hu |first1=Y. F. |last2=Zuin |first2=L. |last3=Wright |first3=G. |last4=Igarashi |first4=R. |last5=McKibben |first5=M. |last6=Wilson |first6=T. |last7=Chen |first7=S. Y. |last8=Johnson |first8=T. |last9=Maxwell |first9=D. |last10=Yates |first10=B. W. |last11=Sham |first11=T. K. |last12=Reininger |first12=R. |year=207 |title=Commissioning and performance of the variable line spacing plane grating monochromator beamline at the Canadian Light Source |journal=Review of Scientific Instruments |volume=78 |issue=8 |pages=083109β083109β5 |doi=10.1063/1.2778613 |pmid=17764315 |bibcode = 2007RScI...78h3109H }}</ref> |- | XSR | X-Ray Synchrotron Radiation | 02B2 | 1 |Bending Magnet | | Accelerator beam diagnostic beamline operating in the X-ray range.<ref name="XSR">{{Cite journal |last1=Bergstrom |first1=John C. |last2=Vogt |first2=Johannes M. |year=2008 |title=The X-ray diagnostic beamline at the Canadian Light Source |journal=Nuclear Instruments and Methods in Physics Research A |volume=587 |issue=2β3 |pages=441β457 |doi=10.1016/j.nima.2008.01.080 |bibcode = 2008NIMPA.587..441B }}</ref> |}
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)