Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
API gravity
(section)
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==Direct measurement of API gravity (hydrometer method)== There are advantages to field testing and on-board conversion of measured volumes to volume correction. This method is detailed in ASTM D287.<ref name=":0">{{Cite web |title=Standard Test Method for API Gravity of Crude Petroleum and Petroleum Products (Hydrometer/Method) |url=https://www.astm.org/d0287-22.html |access-date=2024-08-07 |website=www.astm.org |language=en}}</ref> The hydrometer method is a standard technique for directly measuring API gravity of petroleum and petroleum products.<ref name=":1">{{Cite web |title=Standard Test Method for Density, Relative Density, or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method |url=https://www.astm.org/d1298-12br17e01.html |access-date=2024-08-07 |website=www.astm.org |language=en}}</ref> This method is based on the principle of [[buoyancy]] and utilizes a specially calibrated [[hydrometer]] to determine the API gravity of a liquid sample.<ref name=":2">{{Cite book |last=Speight |first=James G. |url=https://onlinelibrary.wiley.com/doi/book/10.1002/9781118986370 |title=Handbook of Petroleum Product Analysis |date=2014-12-12 |publisher=Wiley |isbn=978-1-118-36926-5 |edition=1 |language=en |doi=10.1002/9781118986370}}</ref> The procedure typically involves the following steps: # '''Sample preparation''': The petroleum sample is brought to a [[Standard temperature and pressure|standard temperature]], usually 60°F (15.6°C), to ensure consistency in measurements across different samples and conditions.<ref name=":0" /> # '''Hydrometer selection''': An appropriate API gravity hydrometer is chosen based on the expected range of the sample. These hydrometers are typically calibrated to read API gravity directly.<ref name=":3">{{Cite book |title=Characterization and Properties of Petroleum Fractions |url=https://www.astm.org/mnl50-eb.html |access-date=2024-08-07 |website=www.astm.org |date=2007 |language=en |doi=10.1520/mnl50-eb |isbn=978-0-8031-3361-7 |editor-last1=Riazi |editor-first1=M. R. }}</ref> # '''Measurement''': The hydrometer is gently lowered into the sample contained in a cylindrical vessel. It is allowed to float freely until it reaches equilibrium.<ref name=":0" /> # '''Reading''': The API gravity is read at the point where the surface of the liquid intersects the hydrometer scale. For maximum accuracy, the reading is taken at the bottom of the [[Meniscus (liquid)|meniscus]] formed by the liquid on the hydrometer stem.<ref name=":1" /> # '''Temperature''' '''correction''': If the measurement is not performed at the standard temperature, a correction factor is applied to adjust the reading to the equivalent value at 60°F.<ref name=":2" /> The hydrometer method is widely used due to its simplicity and low cost. However, it requires a relatively large sample volume and may not be suitable for highly [[Viscosity|viscous]] or [[Opacity|opaque]] fluids.<ref name=":3" /> Proper cleaning and handling of the hydrometer are crucial to maintain accuracy, and for [[Volatile organic compound|volatile]] liquids, special precautions may be necessary to prevent evaporation during measurement.<ref name=":0" />
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)