Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Allen's test
(section)
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
== Significance == The modified Allen's test is also performed prior to [[Coronary artery bypass surgery|heart bypass surgery]]. The [[radial artery]] is occasionally used as a conduit for bypass surgery, and its patency lasts longer in comparison to the [[Great saphenous vein|saphenous vein]]s. Prior to heart bypass surgery, the test is performed to assess the suitability of the radial artery to be used as a conduit. A result of less than 3 seconds is considered as good and suitable. A result of between 3β5 seconds is equivocal, whereas the radial artery will not be considered for [[Graft (surgery)|grafting]] if the result is longer than 5 seconds.<ref>{{cite journal |url=https://www.nejm.org/doi/full/10.1056/NEJMoa1716026 |doi=10.1056/NEJMoa1716026 |title=Radial-Artery or Saphenous-Vein Grafts in Coronary-Artery Bypass Surgery |date=2018 |last1=Gaudino |first1=Mario |last2=Benedetto |first2=Umberto |last3=Fremes |first3=Stephen |last4=Biondi-Zoccai |first4=Giuseppe |last5=Sedrakyan |first5=Art |last6=Puskas |first6=John D. |last7=Angelini |first7=Gianni D. |last8=Buxton |first8=Brian |last9=Frati |first9=Giacomo |last10=Hare |first10=David L. |last11=Hayward |first11=Philip |last12=Nasso |first12=Giuseppe |last13=Moat |first13=Neil |last14=Peric |first14=Miodrag |last15=Yoo |first15=Kyung J. |last16=Speziale |first16=Giuseppe |last17=Girardi |first17=Leonard N. |last18=Taggart |first18=David P. |author19=RADIAL Investigators |journal=New England Journal of Medicine |volume=378 |issue=22 |pages=2069β2077 |pmid=29708851 }}</ref> The utility of the modified Allen's test is questionable,<ref name="pmid11081899">{{cite journal |last1=Jarvis |first1=MA |last2=Jarvis |first2=CL |last3=Jones |first3=R |last4=Spyt |first4=TJ |title=Reliability of Allen's test in selection of patients for radial artery harvest |journal=Ann. Thorac. Surg. |volume=70 |issue=4 |pages=1362β5 |date=October 2000 |pmid=11081899 |doi= 10.1016/S0003-4975(00)01551-4|doi-access=free }}</ref> and no direct correlation with reduced ischemic complications of radial artery cannulation have ever been proven. In 1983, Slogoff and colleagues reviewed 1,782 radial artery cannulations and found that 25% of them resulted in complete radial artery occlusion, without apparent adverse effects.<ref>{{cite journal |last1=Slogoff |first1=S |last2=Keats |first2=AS |last3=Arlund |first3=C |year=1983 |title=On the safety of radial artery cannulation. |journal=Anesthesiology |volume=59 |issue=1 |pages=42β7 |pmid= 6859611|doi= 10.1097/00000542-198307000-00008|doi-access=free }}</ref> A number of reports have been published in which permanent ischemic sequelae occurred even in the presence of a normal Allen's test.<ref>{{cite journal |last1=Thompson |first1=SR |last2=Hirschberg |first2=A |year=1988 |title=Allen's test re-examined. |journal=Crit Care Med |volume=16 |issue=9 |pages=915 |pmid= 3402240|doi=10.1097/00003246-198809000-00025}}</ref><ref>{{cite journal |last=Wilkins |first=RG |year=1985 |title=Radial artery cannulation and ischaemic damage: A review. |journal=Anaesthesia |volume=40 |issue=9 |pages=896β899 |pmid= 3901815|doi= 10.1111/j.1365-2044.1985.tb11055.x|url=https://deepblue.lib.umich.edu/bitstream/2027.42/72040/1/j.1365-2044.1985.tb11055.x.pdf |hdl=2027.42/72040 |s2cid=10669033 |hdl-access=free }}</ref> In addition, the results of Allen's tests do not appear to correlate with distal blood flow as demonstrated by fluorescein dye injections.<ref>{{cite journal |last=McGregor |first=AD |year=1987 |title=The Allen test β an investigation of its accuracy by fluorescein angiography. |journal=J Hand Surg Br Vol |volume=12 |issue=1 |pages=82β85 |pmid= 3572188|doi= 10.1016/0266-7681(87)90065-9}}</ref><ref>{{cite journal |last1=Stead |first1=SW |last2=Stirt |first2=JA |year=1985 |title=Assessment of digital blood flow and palmar collateral circulation. |journal=Journal of Clinical Monitoring and Computing|volume=2 |issue=1 |pages=29β34 |doi= 10.1007/bf02915870|pmid=3835222 |s2cid=39584943 }}</ref> Further modifications to the test have been proposed to improve reliability.<ref name="pmid17643672">{{cite journal |last1=Asif|first1= M|last2=Sarkar|first2=PK |title=Three-digit Allen's test |journal=Annals of Thoracic Surgery |volume=84 |issue=2 |pages=686β687 |date=August 2007 |pmid=17643672 |doi=10.1016/j.athoracsur.2006.11.038 }}</ref>
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)