Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Instrumentation
(section)
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
===Large integrated computer-based systems=== [[Image:Pneumatische regelaar.jpg|thumb|Pneumatic "three term" pneumatic [[PID controller]], widely used before electronics became reliable and cheaper and safe to use in hazardous areas (Siemens Telepneu Example)]] [[File:Kontrollrom Tyssedal.jpg|thumb|A pre-DCS/SCADA era central control room. Whilst the controls are centralised in one place, they are still discrete and not integrated into one system.]] [[File:Leitstand 2.jpg|thumb|A DCS control room where plant information and controls are displayed on computer graphics screens. The operators are seated and can view and control any part of the process from their screens, whilst retaining a plant overview.]] Process control of large industrial plants has evolved through many stages. Initially, control would be from panels local to the process plant. However, this required a large manpower resource to attend to these dispersed panels, and there was no overall view of the process. The next logical development was the transmission of all plant measurements to a permanently staffed central control room. Effectively this was the centralization of all the localized panels, with the advantages of lower manning levels and easy overview of the process. Often the controllers were behind the control room panels, and all automatic and manual control outputs were transmitted back to plant. However, whilst providing a central control focus, this arrangement was inflexible as each control loop had its own controller hardware, and continual operator movement within the control room was required to view different parts of the process. With coming of electronic processors and graphic displays it became possible to replace these discrete controllers with computer-based algorithms, hosted on a network of input/output racks with their own control processors. These could be distributed around plant, and communicate with the graphic display in the control room or rooms. The distributed control concept was born. The introduction of DCSs and [[SCADA]] allowed easy interconnection and re-configuration of plant controls such as cascaded loops and interlocks, and easy interfacing with other production computer systems. It enabled sophisticated alarm handling, introduced automatic event logging, removed the need for physical records such as chart recorders, allowed the control racks to be networked and thereby located locally to plant to reduce cabling runs, and provided high level overviews of plant status and production levels.
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)