Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Interferometry
(section)
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
====Amplitude-splitting inferometers==== [[File:Three amplitude-splitting interferometers.svg|thumb|750px |Figure 6. Three amplitude-splitting interferometers: [[Fizeau interferometer|Fizeau]], [[Mach-Zehnder interferometer|Mach–Zehnder]], and [[Fabry Pérot interferometer|Fabry Pérot]].]] An amplitude splitting interferometer uses a partial reflector to divide the amplitude of the incident wave into separate beams which are separated and recombined. The [[Fizeau interferometer]] is shown as it might be set up to test an [[optical flat]]. A precisely figured reference flat is placed on top of the flat being tested, separated by narrow spacers. The reference flat is slightly beveled (only a fraction of a degree of beveling is necessary) to prevent the rear surface of the flat from producing interference fringes. Separating the test and reference flats allows the two flats to be tilted with respect to each other. By adjusting the tilt, which adds a controlled phase gradient to the fringe pattern, one can control the spacing and direction of the fringes, so that one may obtain an easily interpreted series of nearly parallel fringes rather than a complex swirl of contour lines. Separating the plates, however, necessitates that the illuminating light be collimated. Fig 6 shows a collimated beam of monochromatic light illuminating the two flats and a beam splitter allowing the fringes to be viewed on-axis.<ref name=Guideline>{{cite web |title=Guideline for Use of Fizeau Interferometer in Optical Testing |url=http://engineer.jpl.nasa.gov/practices/2404.pdf |publisher=NASA |access-date=8 April 2012 |archive-url=https://web.archive.org/web/20180925131401/https://engineer.jpl.nasa.gov/practices/2404.pdf |archive-date=25 September 2018 |url-status=dead }}</ref><ref name=OPIFizeau>{{cite web |title=Interferential devices – Fizeau Interferometer |url=http://www.optique-ingenieur.org/en/courses/OPI_ang_M02_C05/co/Contenu_25.html |publisher=Optique pour l'Ingénieur.|access-date=8 April 2012}}</ref> The [[Mach–Zehnder interferometer]] is a more versatile instrument than the Michelson interferometer. Each of the well separated light paths is traversed only once, and the fringes can be adjusted so that they are localized in any desired plane.<ref name=HariharanBasics2007/>{{rp|18}} Typically, the fringes would be adjusted to lie in the same plane as the test object, so that fringes and test object can be photographed together. If it is decided to produce fringes in white light, then, since white light has a limited [[coherence length]], on the order of [[micrometre|micrometers]], great care must be taken to equalize the optical paths or no fringes will be visible. As illustrated in Fig. 6, a compensating cell would be placed in the path of the reference beam to match the test cell. Note also the precise orientation of the beam splitters. The reflecting surfaces of the beam splitters would be oriented so that the test and reference beams pass through an equal amount of glass. In this orientation, the test and reference beams each experience two front-surface reflections, resulting in the same number of phase inversions. The result is that light traveling an equal optical path length in the test and reference beams produces a white light fringe of constructive interference.<ref name=Zetie>{{cite web |author=Zetie, K.P. |author2=Adams, S.F. |author3=Tocknell, R.M. |title=How does a Mach–Zehnder interferometer work?|url=http://www.cs.princeton.edu/courses/archive/fall06/cos576/papers/zetie_et_al_mach_zehnder00.pdf |publisher=Physics Department, Westminster School, London |access-date=8 April 2012}}</ref><ref name=Ashkenas1950>{{cite thesis |last=Ashkenas |first=Harry I. |title=The design and construction of a Mach–Zehnder interferometer for use with the GALCIT Transonic Wind Tunnel. Engineer's thesis |date=1950 |publisher=California Institute of Technology |doi=10.7907/D0V1-MJ80 |url=https://thesis.library.caltech.edu/1483/|type=engd }}</ref> The heart of the [[Fabry–Pérot interferometer]] is a pair of partially silvered glass optical flats spaced several millimeters to centimeters apart with the silvered surfaces facing each other. (Alternatively, a Fabry–Pérot ''etalon'' uses a transparent plate with two parallel reflecting surfaces.)<ref name=HariharanBasics2007/>{{rp|35–36}} As with the Fizeau interferometer, the flats are slightly beveled. In a typical system, illumination is provided by a diffuse source set at the [[focal plane]] of a collimating lens. A focusing lens produces what would be an inverted image of the source if the paired flats were not present, i.e., in the absence of the paired flats, all light emitted from point A passing through the optical system would be focused at point A'. In Fig. 6, only one ray emitted from point A on the source is traced. As the ray passes through the paired flats, it is multiply reflected to produce multiple transmitted rays which are collected by the focusing lens and brought to point A' on the screen. The complete interference pattern takes the appearance of a set of concentric rings. The sharpness of the rings depends on the reflectivity of the flats. If the reflectivity is high, resulting in a high [[Q factor]] (i.e., high finesse), monochromatic light produces a set of narrow bright rings against a dark background.<ref name=Betzler>{{cite web|last=Betzler|first=Klaus|title=Fabry–Perot Interferometer|url=http://www.fen.bilkent.edu.tr/~aykutlu/msn513/fibersensors/fabryperot.pdf|publisher=Fachbereich Physik, Universität Osnabrück|access-date=8 April 2012}}</ref> In Fig. 6, the low-finesse image corresponds to a reflectivity of 0.04 (i.e., unsilvered surfaces) ''versus'' a reflectivity of 0.95 for the high-finesse image. Fig. 6 illustrates the Fizeau, Mach–Zehnder, and Fabry–Pérot interferometers. Other examples of amplitude splitting interferometer include the [[Michelson interferometer|Michelson]], [[Twyman–Green interferometer|Twyman–Green]], Laser Unequal Path, and [[Linnik interferometer]].<ref name=Nolte>{{cite book|last=Nolte|first=David D.|title=Optical Interferometry for Biology and Medicine |date=2012 |publisher=Springer |isbn=978-1-4614-0889-5 |pages=17–26 |url=https://books.google.com/books?id=emFmnDhq9EwC&pg=PA17|bibcode=2012oibm.book.....N}}</ref>
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)