Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Automated analyser
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{Short description|Medical laboratory instrument}} An '''automated analyser''' is a [[medical laboratory]] instrument designed to measure various substances and other characteristics in a number of biological [[Sample (material)|samples]] quickly, with minimal human assistance. These measured properties of blood and other fluids may be useful in the diagnosis of disease. [[File:Cobas 6000.ogv|thumb|[[Roche Cobas 6000]]]] [[File:Cobas u 411.JPG|thumb|Roche Cobas u 411]] [[File:LabMachines.jpg|thumb|Beckman Chemistry analysers: Access (left); Synchron (right).]] [[File:RACKS.jpg|thumb|Racks: for putting samples, quality controls or calibrations. Cobas 6000]] [[File:Tube vacuette.jpg|thumb|These tubes are put in the racks for testing]] [[Spectrophotometry|Photometry]] is the most common method for testing the amount of a specific analyte in a sample. In this technique, the sample undergoes a reaction to produce a color change. Then, a photometer measures the absorbance of the sample to indirectly measure the concentration of analyte present in the sample. The use of an ion-selective electrode (ISE) is another common analytical method that specifically measures ion concentrations. This typically measures the concentrations of sodium, calcium or potassium present in the sample.<ref>{{Cite web|url=https://www.labcompare.com/10-Featured-Articles/138020-Clinical-Chemistry-Analyzers-Technology/|title = Clinical Chemistry Analyzers Technology}}</ref> There are various methods of introducing samples into the analyser. [[Test tube]]s of samples are often loaded into racks. These racks can be inserted directly into some analysers or, in larger labs, moved along an automated track. More manual methods include inserting tubes directly into circular carousels that rotate to make the sample available. Some analysers require samples to be transferred to sample cups. However, the need to protect the health and safety of laboratory staff has prompted many manufacturers to develop analysers that feature closed tube sampling, preventing workers from direct exposure to samples.<ref>{{cite web|url=http://www.beckman.com/literature/ClinDiag/AU%209389%20Tanner%20Case%20Study.pdf |title=Tanner Medical Center Uses Revolutionary SYNCHRON LX®i 725 To Consolidate Testing, Reduce Sample Handling And Increase Safety|accessdate=2007-08-26 |url-status=dead |archiveurl=https://web.archive.org/web/20070928015634/http://www.beckman.com/literature/ClinDiag/AU%209389%20Tanner%20Case%20Study.pdf |archivedate=2007-09-28 }}</ref><ref>{{cite web|url=http://www.bd.com/ds/aboutUs/news/News-05227.asp|title=Microbiology Solutions - BD|website=www.bd.com}}</ref> Samples can be processed singly, in batches, or continuously. The automation of laboratory testing does not remove the need for human expertise (results must still be evaluated by [[medical technologist]]s and other qualified clinical laboratory professionals), but it does ease concerns about error reduction, staffing concerns, and safety. ==Routine biochemistry analysers== These are machines that process a large portion of the samples going into a [[hospital]] or private [[medical laboratory]]. Automation of the testing process has reduced testing time for many analytes from days to minutes. The history of discrete sample analysis for the clinical laboratory began with the introduction of the "Robot Chemist" invented by [[Hans Baruch]] and introduced commercially in 1959<sup>[1]</sup>. The [[AutoAnalyzer]] is an early example of an automated chemistry analyzer using a special flow technique named "continuous flow analysis (CFA)", invented in 1957 by Leonard Skeggs, PhD and first made by the Technicon Corporation. The first applications were for clinical (medical) analysis. The AutoAnalyzer profoundly changed the character of the chemical testing laboratory by allowing significant increases in the numbers of samples that could be processed. Samples used in the analyzers include, but are not limited to, blood, serum, plasma, urine, cerebrospinal fluid, and other fluids from within the body.<ref>{{cite web |title=Clinical Chemistry Analyzer |url=https://www.who.int/medical_devices/innovation/clinical_chemistry_analyzer.pdf |publisher=World Health Organization |accessdate=15 May 2020}}</ref> The design based on separating a continuously flowing stream with air bubbles largely reduced slow, clumsy, and error-prone manual methods of analysis. The types of tests include [[enzyme]] levels (such as many of the [[liver function tests]]), ion levels (e.g. [[sodium]] and [[potassium]], and other tell-tale chemicals (such as [[Blood sugar|glucose]], [[serum albumin]], or [[creatinine]]). Simple ions are often measured with [[ion selective electrode]]s, which let one type of ion through, and measure [[voltage]] differences.<ref>{{cite web|url=http://www.nico2000.net/Book/Guide1.html|title=A Beginners Guide to Ion-Selective Electrodes. All you need to know about theory and practice of ISE measurements, with comprehensive Electrochemical Glossary|website=www.nico2000.net}}</ref> Enzymes may be measured by the rate they change one coloured substance to another; in these tests, the results for enzymes are given as an activity, not as a concentration of the enzyme. Other tests use colorimetric changes to determine the concentration of the chemical in question. Turbidity may also be measured. ==Immuno-based analysers== Antibodies are used by some analysers to detect many substances by [[immunoassay]] and other reactions that employ the use of antibody-antigen reactions. When concentration of these compounds is too low to cause a measurable increase in [[turbidity]] when bound to antibody, more specialised methods must be used. Recent developments include automation for the [[immunohaematology]] lab, also known as [[transfusion medicine]]. ==Hematology analysers== {{main|Hematology analyzer}} These are used to perform [[complete blood count]]s, [[erythrocyte sedimentation rate]]s (ESRs), or [[coagulation]] tests. ===Cell counters=== {{see also|Complete blood count|White blood cell differential}} Automated cell counters sample the blood, and quantify, classify, and describe cell populations using both electrical and optical techniques. Electrical analysis involves passing a dilute solution of the blood through an aperture across which an electrical current is flowing. The passage of cells through the current changes the [[Electrical impedance|impedance]] between the terminals (the [[Coulter principle]]).<ref>{{cite web|url=http://www.beckman.com/coultercounter/homepage_tech_coulter_principle.jsp |title=CoulterCounter.com - the Coulter Principle |accessdate=2007-08-26 |url-status=dead |archiveurl=https://web.archive.org/web/20070928015537/http://www.beckman.com/coultercounter/homepage_tech_coulter_principle.jsp |archivedate=2007-09-28 }}</ref> A lytic reagent is added to the blood solution to selectively lyse the [[Red blood cell|red cells]] (RBCs), leaving only [[White blood cell|white cells]] (WBCs), and [[platelets]] intact. Then the solution is passed through a second detector. This allows the counts of RBCs, WBCs, and platelets to be obtained. The platelet count is easily separated from the WBC count by the smaller impedance spikes they produce in the detector due to their lower cell volumes. Optical detection may be utilised to gain a differential count of the populations of white cell types. A dilute suspension of cells is passed through a flow cell, which passes cells one at a time through a capillary tube past a laser beam. The reflectance, transmission and scattering of light from each cell is analysed by sophisticated software giving a numerical representation of the likely overall distribution of cell populations. Some of the latest hematology instruments may report [[Cell Population Data]] that consist in [[Leukocyte]] morphological information that may be used for flagging [[Cell (biology)|Cell]] abnormalities that trigger the suspect of some [[diseases]]. [[Reticulocyte]] counts can now be performed by many analysers, giving an alternative to time-consuming manual counts. Many automated reticulocyte counts, like their manual counterparts, employ the use of a [[Supravital stain|supravital dye]] such as [[new methylene blue]] to stain the red cells containing [[Reticular fiber|reticulin]] prior to counting.<ref>{{cite web|url=http://www.biology-online.org/dictionary/New_methylene_blue|title=New methylene blue - Biology-Online Dictionary|website=www.biology-online.org|date=7 October 2019}}</ref> Some analysers have a modular slide maker which is able to both produce a blood film of consistent quality and stain the film, which is then reviewed by a medical laboratory professional. ===Coagulometers=== {{further|Coagulation testing}} Automated coagulation machines or Coagulometers measure the ability of blood to clot by performing any of several types of tests including [[Partial thromboplastin time]]s, [[Prothrombin time]]s (and the calculated [[International normalized ratio|INRs]] commonly used for therapeutic evaluation), [[Lupus anticoagulant]] screens, [[D dimer]] assays, and factor assays. Coagulometers require blood samples that have been drawn in tubes containing [[Trisodium citrate|sodium citrate]] as an anticoagulant. These are used because the mechanism behind the anticoagulant effect of sodium citrate is reversible. Depending on the test, different substances can be added to the blood plasma to trigger a clotting reaction. The progress of clotting may be monitored optically by measuring the absorbance of a particular wavelength of light by the sample and how it changes over time. [[File:StaRRsed Inversa, automated Westergren based ESR 'analyzer'.jpg|thumb|upright=0.55|right|StaRRsed Inversa, automated Westergren-based ESR 'analyzer']].. ===Other hematology apparatus=== Automatic [[erythrocyte sedimentation rate]] (ESR) readers, while not strictly analysers, do preferably have to comply to the 2011-published CLSI (Clinical and Laboratory Standards Institute) "Procedures for the Erythrocyte Sedimentation Rate Test: H02-A5 and to the ICSH (International Council for Standardization in Haematology) published "ICSH review of the measurement of the erythrocyte sedimentation rate", both indicating the only reference method, being Westergren, explicitly indicating the use of '''diluted''' blood (with sodium citrate), in 200 mm pipettes, bore 2.55 mm. After 30 or 60 minutes being in a vertical position, with no draughts and vibration or direct sunlight allowed, an optical reader determines how far the [[Red blood cell|red cells]] have fallen by detecting the level. ==Miscellaneous analysers== Some tests and test categories are unique in their mechanism or scope, and require a separate analyser for only a few tests, or even for only ''one'' test. Other tests are esoteric in nature—they are performed less frequently than other tests, and are generally more expensive and time-consuming to perform. Even so, the current{{When|date=February 2014}} shortage of qualified clinical laboratory professionals<ref>{{Cite web |url=http://www.astho.org/pubs/LABORATORYWORKERSHORTAGE.pdf |title=Public Health Workforce Shortage: Laboratory Scientists and Technicians |date=December 2004|access-date=2007-08-26 |archive-url=https://web.archive.org/web/20071006120151/http://www.astho.org/pubs/LABORATORYWORKERSHORTAGE.pdf |archive-date=2007-10-06 |url-status=dead }}</ref> has spurred manufacturers to develop automated systems for even these rarely performed tests. Analysers that fall into this category include instruments that perform: * [[DNA]] labeling and detection * [[Osmole|Osmolarity and osmolality]] measurement * Measurement of [[Glycated hemoglobin|glycated haemoglobin]] (haemoglobin A1C), and * Aliquotting and routing of samples throughout the laboratory == See also == {{Commons category|Automated analysers}} * [[Comprehensive metabolic panel]] * [[Medical technologist]] == Notes == 1. Rosenfeld, Louis. Four Centuries of Clinical Chemistry. Gordon and Breach Science Publishers, 1999. {{ISBN|90-5699-645-2}}. Pp. 490–492 == References == {{reflist}} <!--======================== {{No more links}} ============================ | PLEASE BE CAUTIOUS IN ADDING MORE LINKS TO THIS ARTICLE. Wikipedia | | is not a collection of links nor should it be used for advertising. | | | | Excessive or inappropriate links WILL BE DELETED. | | See [[Wikipedia:External links]] & [[Wikipedia:Spam]] for details. | | | | If there are already plentiful links, please propose additions or | | replacements on this article's discussion page, or submit your link | | to the relevant category at the Open Directory Project (dmoz.org) | | and link back to that category using the {{dmoz}} template. | ======================= {{No more links}} =============================--> {{DEFAULTSORT:Automated Analyser}} [[Category:Laboratory equipment]] [[Category:Measuring instruments]] [[Category:Clinical pathology]] [[Category:Drugs developed by Hoffmann-La Roche]] [[Category:Articles containing video clips]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Cite web
(
edit
)
Template:Commons category
(
edit
)
Template:Further
(
edit
)
Template:ISBN
(
edit
)
Template:Main
(
edit
)
Template:Reflist
(
edit
)
Template:See also
(
edit
)
Template:Short description
(
edit
)
Template:When
(
edit
)