Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Backflow prevention device
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{Short description|Device that prevents undesired water flow}} {{refimprove|date=March 2013}} [[File:Back siphon example hosepipe up hill.svg|thumb|In this situation, dirty water from the hillside pool will ''back-[[siphon]]'' or ''back-flow'' down the [[hosepipe]] and into the clean water tank. To prevent this from happening, the house's external [[Tap (valve)|tap]] should be fitted with a backflow prevention device.]] A '''backflow prevention device''' is used to protect [[potable water]] supplies from contamination or pollution due to [[backflow (plumbing)|backflow]]. In [[water distribution system]]s, water is normally maintained at a significant pressure to enable water to flow from the tap, shower, or other fixture. Water pressure may fail or be reduced when a water main bursts, pipes freeze, or there is unexpectedly high demand on the water system (for example, when several [[fire hydrant]]s are opened). Reduced pressure in the pipe may allow contaminated [[ground water|water from the soil]], from storage, or from other sources to be drawn up into the system. ==Terminology== '''Backflow''' means the undesirable reversal of flow of a liquid, gas, or suspended solid into the potable water supply; a '''backflow preventer''' is designed to keep this from happening. Points at which a potable water system connects with a non-potable water system are called '''cross connections'''. Such connections occur naturally in appliances such as [[clothes washer]]s and [[dishwasher]]s, but they must be carefully designed and installed to prevent backflow. Another common location for a backflow preventer is the connection of a [[fire sprinkler]] system to a water main, to prevent pressurized water from flowing from the fire suppression system into the public water supply. '''Back-siphonage''' occurs when higher pressure fluids, gases, or suspended solids move to an area of lower pressure fluids. For example, when a [[drinking straw]] is used to consume a beverage, suction reduces the pressure of fluid inside the straw, causing liquid to move from the cup to inside the straw and then into the drinker's mouth. A significant drop of pressure in a water delivery system creates a similar suction, ''pulling'' possibly undesirable material into the system. This is an example of an '''indirect cross-connection'''. '''Back-pressure''' occurs for example when air is blown through the straw and bubbles begin to erupt at the submerged end. If, instead of air, [[natural gas]] had been forced into a potable water tank, the gas in turn could be carried to a kitchen faucet. This is an example of a '''direct cross-connection''', with undesirable material being ''pushed'' into the system. Back pressure can force an undesirable contaminant to enter potable water piping. Sources of back pressure may be boilers, heat exchanging equipment, power washing equipment, fire sprinklers, or pumps in the water distribution system. In some cases there may be an almost continuous risk of overcoming the static water pressure in the piping. To reduce the risk of contamination, a backflow preventer can be fitted. A backflow preventer is also important when potentially toxic chemicals are used, for instance for commercial/industrial [[descaling]] of boilers, or when chemical [[bleach]]es are used for residential power washing. A closely related device is the '''[[backwater valve]]''', which is designed to prevent [[sewage]] from backing up into a building and causing basement flooding.<ref name=Backwater>{{cite web|title=Backwater Valve Installation|url=http://www.absolutedp.com/backwater-valve-installation|publisher=Absolute Draining & Plumbing|accessdate=9 October 2014}}</ref><!-- NOTE: The forgoing ref is far from ideal, but until something better is found, it does contain useful information --> ==Preventive devices== [[File:Verifiedbackflow.jpeg|thumb|Backflow prevention device]] The simplest, most reliable way to provide backflow prevention is to provide an [[air gap (plumbing)|air gap]]. An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool. A simple air gap has no moving parts, other than flowing water. Many [[plumbing code]]s specify a minimum air gap distance required for various circumstances, such as a drain connection for a dishwasher, e.g., [[BS 6282]]. Alternatively, a specialized backflow preventer valve may be installed at strategic locations in the plumbing system wherever there is a risk of contaminated fluids entering the water supply pipes. These valves are used where there is not sufficient vertical clearance or physical space to install an air gap, or when pressurized operation or other factors rule out use of an air gap. Because these valves use moving parts, they are often required to be inspected or tested periodically. ==Regulatory requirements== To prevent contamination due to back pressure, many health regulatory regimes require an air gap or mechanical backflow prevention assembly between the delivery point of mains water and local storage or use.<ref>{{Cite web|url=http://www.opsi.gov.uk/si/si1999/99114802.htm|title=The Water Supply (Water Fittings) Regulations 1999|accessdate=July 26, 2010| archiveurl= https://web.archive.org/web/20100823022423/http://www.opsi.gov.uk/si/si1999/99114802.htm| archivedate= 23 August 2010 | url-status= live}}</ref> Where submerged mains inflow is permitted,{{elucidate|date=March 2013}} a backflow prevention assembly is required, which protects the potable water system from contamination hazards. A [[check valve]] is a basic form of backflow prevention, but often more complex devices are required because check valves are not considered to be reliable, when compared to more sophisticated devices with redundancies and reduced-pressure zones.{{elucidate|date=September 2015}} In many countries. approved backflow prevention assemblies are required by law, and must be installed in accordance with plumbing or [[building code]]s.{{examples|date=February 2012}} A typical backflow assembly has test cocks and shut-off valves, and must be tested when installed, if relocated or repaired, and also on a periodic basis.{{citation needed|date=March 2013}} In the US, the [[United States Environmental Protection Agency|Environmental Protection Agency]] (EPA) holds local water suppliers responsible for maintaining a certain amount of purity in potable water systems. Many states and/or local municipalities require annual testing of backflow prevention assemblies. In most cases, the law requires a double check (DC), reduced pressure principle device ([[Reduced pressure zone device|RP]]) device, or an air gap when backflow prevention is mandated.{{citation needed|date=March 2013}} ==Partial list of backflow prevention devices and assemblies== *[[Air gap (plumbing)|Air gap]] (AG the purest form of backflow prevention) *[[Atmospheric vacuum breaker]] (AVB) *[[Check valve]] (usually not a legally approved method of backflow prevention.) *[[Chemigation valve]] (primarily used in agriculture) *[[Double check valve|Double check valve assembly]] (DCVA) *[[Dual check valve]] (A dual check is not a testable device and is mainly used on residential customers) *[[Pressure vacuum breaker assembly]] (PVB) *[[Reduced pressure zone device]] (RPZ) *[[Spill resistant pressure vacuum breaker assembly]] (SPVB) *[[Vacuum breaker]] ==See also== * [[Backflow (plumbing)]] ==References== {{Reflist}} ==External links== *[http://www.iapmo.org International Association of Plumbing and Mechanical Officials] *[http://www.dwbp-online.com Drinking Water & Backflow Prevention magazine] *[http://www.abpa.org The American Backflow Prevention Association] *[http://www.usc.edu/fccchr Foundation for Cross-Connection Control and Hydraulic Research] {{Backflow}} {{Plumbing}} [[Category:Irrigation]] [[Category:Backflow]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Backflow
(
edit
)
Template:Citation needed
(
edit
)
Template:Cite web
(
edit
)
Template:Elucidate
(
edit
)
Template:Examples
(
edit
)
Template:Plumbing
(
edit
)
Template:Refimprove
(
edit
)
Template:Reflist
(
edit
)
Template:Short description
(
edit
)