Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Circuit breaker
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{Short description|Automatic circuit protection device}} {{For-multi|the stock market term|Trading curb||Circuit breaker (disambiguation)}} {{Infobox electronic component | component = Circuit breaker | photo = Jtecul.jpg | caption = A two-pole miniature circuit breaker | invented = | first_produces = | symbol = [[File:BreakerSymbols.svg]] }} [[File:AEG Circuit breaker type ME 800 (1).JPG|thumb|An air circuit breaker for low-voltage (less than 1,000 volt) power distribution switchgear]] [[File: Four 1 pole circuit breakers fitted in a meter box.jpg|thumb|Four one-pole miniature circuit breakers]] {{Electrical wiring sidebar}} A '''circuit breaker''' is an electrical safety device designed to protect an [[Electrical network|electrical circuit]] from damage caused by current in excess of that which the equipment can safely carry ([[overcurrent]]). Its basic function is to interrupt current flow to protect equipment and to prevent [[fire]]. Unlike a [[fuse (electrical)|fuse]], which operates once and then must be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation. Circuit breakers are commonly installed in [[distribution board]]s. Apart from its safety purpose, a circuit breaker is also often used as a main [[switch]] to manually disconnect ("rack out") and connect ("rack in") electrical power to a whole electrical sub-network.<ref>[https://safe-t-rack.com/frequently-asked-questions/ Frequently Asked Questions] at the [https://safe-t-rack.com/ Safe-T-Rack] company website. Accessed on 2024-07-28.</ref> Circuit breakers are made in varying current ratings, from devices that protect low-current circuits or individual household appliances, to [[switchgear]] designed to protect [[high voltage|high-voltage]] circuits feeding an entire city. Any device which protects against excessive current by automatically removing power from a faulty system, such as a circuit breaker or [[fuse (electrical)|fuse]], can be referred to as an ''over-current protection device'' (''OCPD''). ==Origins== An early form of circuit breaker was described by [[Thomas Edison]] in an 1879 patent application, although his commercial power distribution system used [[fuse (electrical)|fuses]].<ref>Robert Friedel and Paul Israel, ''Edison's Electric Light: Biography of an Invention'', Rutgers University Press, New Brunswick New Jersey USA,1986 {{ISBN|0-8135-1118-6}} pp.65-66</ref> Its purpose was to protect lighting circuit wiring from accidental short circuits and overloads. A modern miniature circuit breaker similar to the ones now in use was patented by [[Brown, Boveri & Cie]] in 1924. Hugo Stotz, an engineer who had sold his company to Brown, Boveri & Cie, was credited as the inventor on German patent 458392.<ref>{{cite web|url = http://www.abb.de/cawp/deabb201/061462650496e146c12570880035eede.aspx|title = "1920-1929 Stotz miniature circuit breaker and domestic appliances", ABB, 2006-01-09, accessed 4 July 2011|access-date = 2011-07-04|archive-date = 2013-10-29|archive-url = https://web.archive.org/web/20131029194804/http://www.abb.de/cawp/deabb201/061462650496e146c12570880035eede.aspx|url-status = live}}</ref> Stotz's invention was the forerunner of the modern thermal-magnetic breaker commonly used in household load centers to this day. Interconnection of multiple generator sources into an electrical grid required the development of circuit breakers with increasing voltage ratings and increased ability to safely interrupt the increasing short-circuit currents produced by networks. Simple air-break manual switches produced hazardous arcs when interrupting high-voltage circuits; these gave way to oil-enclosed contacts, and various forms using the directed flow of pressurized air, or pressurized oil, to cool and interrupt the arc. By 1935, the specially constructed circuit breakers used at the [[Boulder Dam]] project used eight series breaks and pressurized oil flow to interrupt faults of up to 2,500 MVA, in three AC cycles.<ref>{{cite book |editor-first=Charles H. |editor-last=Flurscheim |title=Power Circuit Breaker Theory and Design |edition=Second |publisher=[[Institution of Engineering and Technology (professional society)|IET]] |year=1982 |isbn=0-906048-70-2 |chapter=Chapter 1}}</ref> ==Operation== All circuit breaker systems have common features in their operation, but details vary substantially depending on the voltage class, current rating and type of the circuit breaker. The circuit breaker must first detect a fault condition. In small mains and [[low voltage|low-voltage]] circuit breakers, this is usually done within the device itself. Typically, the heating or magnetic effects of electric current are employed. Circuit breakers for large currents or high voltages are usually arranged with [[protective relay]] pilot devices to sense a fault condition and to operate the opening mechanism. These typically require a separate power source, such as a [[battery (electricity)|battery]], although some high-voltage circuit breakers are self-contained with [[current transformer]]s, [[protective relay]]s, and internal power sources. Once a fault is detected, the circuit breaker contacts must open to interrupt the circuit; this is commonly done using mechanically stored energy contained within the breaker, such as a spring or compressed air to separate the contacts. A breaker may also use the higher current caused by the fault to separate the contacts, via thermal expansion or increased magnetic field. A small circuit breaker typically has a manual control lever to switch the circuit off or reset a tripped breaker, while a larger unit may use a [[solenoid]] to trip the mechanism, and an [[electric motor]] to restore energy to springs (which rapidly separate contacts when the breaker is tripped). The circuit breaker contacts must carry the load current without excessive heating, and must also withstand the heat of the arc produced when interrupting (opening) the circuit. Contacts are made of copper or copper alloys, silver alloys and other highly conductive materials. Service life of the contacts is limited by the erosion of contact material due to arcing while interrupting the current. Miniature and molded-case circuit breakers are usually discarded when the contacts have worn, but power circuit breakers and high-voltage circuit breakers have replaceable contacts. When a high current or voltage is interrupted, an [[electric arc|arc]] is generated. The maximum length of the arc is generally proportional to the voltage while the intensity (or heat) is proportional to the current. This arc must be contained, cooled and extinguished in a controlled way, so that the gap between the contacts can again withstand the voltage in the circuit. Different circuit breakers use [[Vacuum interrupter|vacuum]], air, [[insulating gas]], or [[transformer oil|oil]] as the medium the arc forms in. Different techniques are used to extinguish the arc including * Lengthening or deflecting the arc * Intensive cooling (in jet chambers) * Division into partial arcs * Zero-point quenching (contacts open at the moment in the [[alternating current|AC]] waveform at which the current and potential are near zero, effectively breaking no load current at the time of opening. The zero-crossing occurs at twice the line frequency; i.e., 100 times per second for 50 Hz and 120 times per second for 60 Hz AC.) * Connecting [[capacitor]]s in parallel with contacts in [[direct current|DC]] circuits. Finally, once the fault condition has been cleared, the contacts must again be closed to restore power to the interrupted circuit. ==Arc interruption== [[File:Arc-chute 1.21.1.jpg|thumb|High voltage plasma arc chutes inside a Benedict LS25 Solar DC Isolator switch]] Low-voltage '''miniature circuit breakers''' ('''MCB''') use air alone to extinguish the arc. These circuit breakers contain so-called arc chutes, a stack of mutually insulated parallel metal plates that divide and cool the arc. By splitting the arc into smaller arcs the arc is cooled down while the arc voltage is increased and serves as an additional [[electrical impedance|impedance]] that limits the current through the circuit breaker. The current-carrying parts near the contacts provide easy deflection of the arc into the arc chutes by a magnetic force of a current path, although [[magnetic blowout]] coils or [[permanent magnets]] could also deflect the arc into the arc chute (used on circuit breakers for higher ratings). The number of plates in the arc chute is dependent on the short-circuit rating and nominal voltage of the circuit breaker. In larger ratings, oil circuit breakers rely upon vaporization of some of the oil to blast a jet of oil through the arc.<ref>{{Cite book |first=B. M. |last=Weedy |title=Electric Power Systems |edition=Second |publisher=John Wiley and Sons |location=London |year=1972 |isbn=0-471-92445-8 |pages=[https://archive.org/details/electricpowersys0000weed/page/428 428–430] |url-access=registration |url=https://archive.org/details/electricpowersys0000weed/page/428 }}</ref> Gas (usually [[sulfur hexafluoride]]) circuit breakers sometimes stretch the arc using a magnetic field, and then rely upon the [[dielectric strength]] of the sulfur hexafluoride (SF<sub>6</sub>) to quench the stretched arc. [[Vacuum]] circuit breakers have minimal arcing (as there is nothing to ionize other than the contact material). The arc is quenched when it is stretched a very small amount (less than {{convert|3|mm|in|sigfig=1|abbr=on}}). Vacuum circuit breakers are frequently used in modern medium-voltage switch gear to {{nowrap|{{val|38000}} volts}}. Air circuit breakers may use [[compressed air]] to blow out the arc, or alternatively, the contacts are rapidly swung into a small sealed chamber, the escaping of the displaced air thus blowing out the arc. Circuit breakers are usually able to terminate all current very quickly: typically the arc is extinguished between 30 and 150 ms after the mechanism has been tripped, depending upon age and construction of the device. The maximum current value and let-through energy determine the quality of the circuit breakers. ==Short circuit== <!--"Ampere Interrupting Capacity" redirects here.--> Circuit breakers are rated both by the normal current that they are expected to carry, and the maximum short-circuit current that they can safely interrupt. This latter figure is the '''ampere interrupting capacity''' ('''AIC''') of the breaker. Under short-circuit conditions, the calculated or measured maximum [[prospective short-circuit current]] may be many times the normal, rated current of the circuit. When electrical contacts open to interrupt a large current, there is a tendency for an [[electric arc|arc]] to form between the opened contacts, which would allow the current to continue. This condition can create conductive ionized gases and molten or vaporized metal, which can cause the further continuation of the arc or create additional short circuits, potentially resulting in the explosion of the circuit breaker and the equipment that it is installed in. Therefore, circuit breakers incorporate various features to divide and extinguish the arcs. The maximum short-circuit current that a breaker can interrupt is determined by testing. Application of a breaker in a circuit with a prospective short-circuit current higher than the breaker's interrupting capacity rating may result in failure of the breaker to safely interrupt a fault. In a worst-case scenario, a breaker may successfully interrupt a fault only to explode when reset. Typical domestic panel circuit breakers are rated to interrupt {{val|6|ul=kA}} ({{val|6000|u=A}}) short-circuit current.<!--Other common values are 10 and 25 kA.--> Miniature circuit breakers used to protect control circuits or small appliances may not have sufficient interrupting capacity to use at a panel board; these circuit breakers are called "supplemental circuit protectors" to distinguish them from distribution-type circuit breakers. ==Standard current ratings== [[File:Standard Trip Characteristic of a Thermomagnetic Circuit Breaker.svg|thumb|Time till trip versus current as multiple of nominal current]] Circuit breakers are manufactured with standard ratings, using a system of [[preferred number]]s to create a useful selection of ratings. A miniature circuit breaker has a fixed trip setting; changing the operating current value requires replacing the whole circuit breaker. Circuit breakers with higher ratings can have adjustable trip settings, allowing fewer standardized products to be used, adjusted to the applicable precise ratings when installed. For example, a circuit breaker with a 400 ampere ''frame size'' might have its over-current detection threshold set only 300 amperes where that rating is appropriate. For low-voltage distribution circuit breakers an international standard, IEC 60898-1, defines ''rated current'' as the maximum current that a breaker is designed to carry continuously. The commonly available preferred values for rated current are 1{{Spaces}}A, 2{{Spaces}}A, 4{{Spaces}}A, 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A,<ref>{{Cite web |date=16 September 2016 |title=What is an MCB and how does it work? |url=https://www.fusebox.shop/pages/what-is-an-mcb-and-how-does-it-work |url-status=live |archive-url=https://web.archive.org/web/20180711194710/https://www.consumerunitworld.co.uk/what-is-an-mcb-and-how-does-it-work-328-c.asp |archive-date=11 July 2018 |access-date=11 July 2018 |website=Fusebox Shop }}</ref> and 125 A. The circuit breaker is labeled with the rated current in [[ampere]]s prefixed by a letter, which indicates the ''instantaneous tripping current'' that causes the circuit breaker to trip without intentional time delay expressed in multiples of the rated current: {| class="wikitable" |- ! Type ! Instantaneous tripping current |- | B | 3–5 times rated current {{var|I<sub>n</sub>}}, e.g. a nominally {{nowrap|10 A}} device will trip at 30–50 A |- | C | 5–10 times {{var|I<sub>n</sub>}} |- | D | 10–14 times {{var|I<sub>n</sub>}} |- | K | 8–12 times {{var|I<sub>n</sub>}} For the protection of loads that cause frequent short-duration (approximately {{nowrap|400 ms}} to {{nowrap|2 s}}) current peaks in normal operation |- | Z | 2–3 times {{var|I<sub>n</sub>}} for durations on the order of tens of seconds. For the protection of loads such as semiconductor devices or measuring circuits using current transformers. |} Circuit breakers are also rated by the maximum fault current that they can interrupt; this allows use of more economical devices on systems unlikely to develop the high short-circuit current found on, for example, a large commercial building distribution system. In the United States, [[Underwriters Laboratories]] (UL) certifies equipment ratings, called Series Ratings (or "integrated equipment ratings") for circuit breaker equipment used for buildings. Power circuit breakers and medium- and high-voltage circuit breakers used for industrial or electric power systems are designed and tested to [[ANSI]] or [[IEEE]] standards in the C37 series. For example, standard C37.16 lists preferred frame size current ratings for power circuit breakers in the range of 600 to 5000 amperes. Trip current settings and time–current characteristics of these breakers are generally adjustable. For medium- and high-voltage circuit breakers used in [[switchgear]], [[electrical substation|substations]] and generating stations, relatively few standard frame sizes are generally manufactured. These circuit breakers are usually controlled by separate [[protective relay]] systems, offering adjustable tripping current and time settings as well as allowing for more complex protection schemes. ==Types== [[File:LargeCircuitBreaker.jpg|thumb|Front panel of a 1250 A air circuit breaker manufactured by ABB. This low-voltage power circuit breaker can be withdrawn from its housing for servicing. Trip characteristics are configurable via [[DIP switch]]es on the front panel.]] Many classifications of circuit breakers can be made, based on their features such as voltage class, construction type, interrupting type, and structural features. ===Low-voltage=== Low-voltage (less than 1,000 V<sub>AC</sub>) types are common in domestic, commercial and industrial application, and include: * Miniature circuit breaker (MCB)—rated current up to 125 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category. * Molded Case Circuit Breaker (MCCB)—rated current up to 1,600 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in higher-rated units. * Low-voltage power circuit breakers can be mounted in multiple tiers in low-voltage switchboards or [[switchgear]] cabinets. The characteristics of low-voltage circuit breakers are given by international standards such as IEC 947. These circuit breakers are often installed in draw-out enclosures that allow removal and interchange without dismantling the switchgear. Large low-voltage molded-case and power circuit breakers may have electric motor operators so they can open and close under remote control. These may form part of an [[automatic transfer switch]] system for standby power. Low-voltage circuit breakers are also made for direct-current (DC) applications, such as for subway lines. Direct current requires special breakers because the arc is continuous—unlike an AC arc, which tends to go out on each half cycle, a direct-current circuit breaker has a blow-out coil that generates a magnetic field that rapidly stretches the arc. Small circuit breakers are either installed directly in equipment or arranged in [[distribution board|breaker panel]]s. [[File:Circuitbreaker.jpg|thumb|Inside a miniature circuit breaker]]The [[DIN rail|DIN-rail]]-mounted thermal-magnetic miniature circuit breaker is the most common style in modern domestic [[consumer unit]]s and commercial electrical [[distribution board]]s throughout [[Europe]]. The design includes the following components: # Actuator [[lever]]{{dash}}used to manually trip and reset the circuit breaker. Also indicates the status of the circuit breaker (On or Off/tripped). Most breakers are designed so they can still trip even if the lever is held or locked in the "on" position. This is sometimes referred to as "free trip" or "positive trip" operation. # Actuator mechanism{{dash}}forces the contacts together or apart. # Contacts{{dash}}allow current when touching and break the current when moved apart. # Terminals # Bimetallic strip{{dash}}separates contacts in response to smaller, longer-term overcurrents # Calibration [[screw]]{{dash}}allows the [[manufacturer]] to precisely adjust the trip current of the device after assembly. # Solenoid{{dash}}separates contacts rapidly in response to high overcurrents # Arc divider/extinguisher ===Solid-state=== ''Solid-state'' circuit breakers (SSCBs), also known as ''digital'' circuit breakers, are a technological innovation which promises to advance circuit breaker technology out of the mechanical level, into the electrical. This promises several advantages, such as acting much more quickly (breaking circuits in fractions of microseconds), better monitoring of circuit loads and longer lifetimes.<ref name="eeweb">{{Cite web |url=https://www.eeweb.com/app-notes/solid-state-circuit-breaker |title=Solid State Circuit Breaker |access-date=2018-11-14 |archive-date=2022-01-25 |archive-url=https://web.archive.org/web/20220125091913/https://www.eeweb.com/solid-state-circuit-breaker/ |url-status=live }}</ref> Solid-state circuit breakers have been developed for medium-voltage DC power and can use silicon carbide transistors or integrated gate-commutated thyristors (IGCTs) for switching.<ref>{{cite web | url=https://spectrum.ieee.org/atom-power-is-launching-the-era-of-digital-circuit-breakers | title=Atom Power is Launching the Era of Digital Circuit Breakers{{dash}}IEEE Spectrum }}</ref><ref>{{cite journal | url=https://ieeexplore.ieee.org/document/9120203 | title=A Review of Solid-State Circuit Breakers | date=2021 | doi=10.1109/TPEL.2020.3003358 | s2cid=221590105 | last1=Rodrigues | first1=Rostan | last2=Du | first2=Yu | last3=Antoniazzi | first3=Antonello | last4=Cairoli | first4=Pietro | journal=IEEE Transactions on Power Electronics | volume=36 | issue=1 | pages=364–377 | bibcode=2021ITPE...36..364R | url-access=subscription }}</ref><ref>{{Cite book |last1=Kempkes |first1=M. |last2=Roth |first2=I. |last3=Gaudreau |first3=M. |chapter=Solid-state circuit breakers for Medium Voltage DC power |date=2011 |title=2011 IEEE Electric Ship Technologies Symposium |chapter-url=http://www.divtecs.com/data/File/papers/PDF/mvdc_full%20paper.pdf |url-status=dead |pages=254–257 |publisher=IEEE |doi=10.1109/ests.2011.5770877 |isbn=978-1-4244-9272-5 |archive-url=https://web.archive.org/web/20181222212258/http://www.divtecs.com:80/data/File/papers/PDF/mvdc_full%20paper.pdf |archive-date=December 22, 2018}}</ref> ===Magnetic=== A ''magnetic'' circuit breaker uses a [[solenoid]] ([[electromagnet]]) whose pulling force increases with the [[electric current|current]]. Certain designs utilize electromagnetic forces in addition to those of the solenoid. The circuit breaker contacts are held closed by a latch. As the current in the solenoid increases beyond the rating of the circuit breaker, the solenoid's pull releases the latch, which lets the contacts open by spring action. They are the most commonly used circuit breakers in the United States. ===Thermal–magnetic=== [[File:SHT-06.jpg|thumb|Shihlin Electric MCCB with SHT]] A ''thermal–magnetic'' circuit breaker, which is the type found in most [[distribution board]]s in Europe and countries with a similar wiring arrangement, incorporates both techniques with the electromagnet responding instantaneously to large surges in current (such as short circuits) and the bimetallic strip responding to lesser but longer-term over-current conditions. The thermal portion of the circuit breaker provides a time-response feature that trips the circuit breaker sooner for larger over-currents but allows smaller overloads to persist for a longer time. This allows short current spikes such as are produced when a motor or other non-resistive load is switched on. With a very large over-current, such as may be caused short circuit, the magnetic element trips the circuit breaker with no intentional additional delay.<ref>John Matthews ''Introduction to the Design and Analysis of Building Electrical Systems'' Springer 1993 0442008740 page 86</ref> ===Magnetic–hydraulic=== A ''magnetic–hydraulic'' circuit breaker uses a solenoid coil to provide operating force to open the contacts. A magnetic–hydraulic breaker incorporates a hydraulic time delay feature using a viscous fluid. A spring restrains the core until the current exceeds the breaker rating. During an overload, the speed of the solenoid motion is restricted by the fluid. The delay permits brief current surges beyond normal running current for motor starting, energizing equipment, etc. Short-circuit currents provide sufficient solenoid force to release the latch regardless of core position thus bypassing the delay feature. Ambient temperature affects the time delay but does not affect the current rating of a magnetic breaker.<ref>Hwaiyu Geng, ''Data Center Handbook'', John Wiley & Sons,2014 page 542</ref> A large power circuit breaker, such as one applied in circuits of more than 1000 volts, may incorporate hydraulic elements in the contact operating mechanism. Hydraulic energy may be supplied by a pump or stored in accumulators. These form a distinct type from oil-filled circuit breakers where oil is the arc-extinguishing medium.<ref>G R Jones (ed), ''Electrical Engineer's Reference Book'', Butterworth{{dash}}Heinemann Ltd, 1993, page 25/14</ref> ===Common-trip (ganged) breakers=== [[File:Breaker3phase2a proc.jpg|thumb|Three-pole common-trip breaker for supplying a three-phase device. This breaker has a 2 A rating.]] To provide simultaneous breaking on multiple circuits from a fault on any one, circuit breakers may be made as a ganged assembly. This is a very common requirement for three-phase systems, where breaking may be either three- or four-pole (solid or switched neutral). Some makers make ganging kits to allow groups of single-phase breakers to be interlinked as required. In the US, where split-phase supplies are common, in a branch circuit with more than one live conductor, each live conductor must be protected by a breaker pole. To ensure that all live conductors are interrupted when any pole trips, a ''common-trip'' set of breakers must be used. These may either contain two or three tripping mechanisms within one case or, for small breakers, have the breakers externally tied together via their operating handles. Two-pole common-trip breakers are common on 120/240-volt systems where 240 volt loads (including [[major appliance]]s or further distribution boards) span the two live wires. Three-pole common-trip breakers are typically used to supply [[three-phase electric power|three-phase power]] to powerful motors or further distribution boards. Separate circuit breakers must never be used for live and neutral, because if the neutral is disconnected while the live conductor stays connected, a very dangerous condition arises: the circuit appears de-energized (appliances don't work), but wires remain live and some [[residual-current device]]s (RCDs) may not trip if someone touches the live wire (because some RCDs need power to trip). This is why only common-trip breakers must be used when neutral wire switching is needed. ===Shunt-trip units=== A shunt-trip unit appears similar to a normal breaker and the moving actuators are ''ganged'' to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or {{nbsp}} DC. These are often used to cut the power when a high-risk event occurs, such as a fire or flood alarm, or another electrical condition, such as over-voltage detection. Shunt trips may be a user-fitted accessory to a standard breaker or supplied as an integral part of a circuit breaker. ===Medium-voltage=== [[File:Siemens WL II 2500N air circuit breaker.jpg|thumb|A Siemens air circuit breaker rated for 1000 V and 2500 A continuous current mounted on a motor control cubicle]] Medium-voltage circuit breakers rated between 1 and 72{{nbsp}}kV may be assembled into metal-enclosed switchgear line-ups for indoor use or may be individual components installed outdoors in a [[electrical substation|substation]]. Air-break circuit breakers replaced oil-filled units for indoor applications, but are now themselves being replaced by vacuum circuit breakers (up to about 40.5{{nbsp}}kV). Like the high-voltage circuit breakers described below, these are also operated by current-sensing protective [[relay]]s operated through [[current transformer]]s. The characteristics of MV breakers are given by international standards such as IEC 62271. Medium-voltage circuit breakers nearly always use separate current sensors and [[protective relay]]s instead of relying on built-in thermal or magnetic overcurrent sensors. Medium-voltage circuit breakers can be classified by the medium used to extinguish the arc: * [[Vacuum interrupter|Vacuum circuit breakers]]—With rated current up to 6,300{{nbsp}}A, and higher for generator circuit breakers application (up to 16,000{{nbsp}}A & 140{{nbsp}}kA). These breakers interrupt the current by creating and extinguishing the arc in a vacuum container{{dash}}aka "bottle". Long life bellows are designed to travel the 6–10 mm the contacts must part. These are generally applied for voltages up to about 40,500{{nbsp}}V,<ref>A few manufacturers now offer a single-bottle vacuum breaker rated up to 72.5{{nbsp}}kV and even 145{{nbsp}}kV. See https://www.edu-right.com/full-knowledge-about-integrated{{Dead link|date=July 2019 |bot=InternetArchiveBot |fix-attempted=yes }} Electrical Engineering in India, vol 157 issue 4 pages 13-23</ref> which corresponds roughly to the medium-voltage range of power systems. Vacuum circuit breakers have longer life expectancy between overhaul than do other circuit breakers. In addition their [[global warming potential]] is by far lower than [[Sulfur hexafluoride circuit breaker|SF<sub><big>6</big></sub> circuit breaker]]. * Air circuit breakers—Rated current up to 6,300{{nbsp}}A and higher for generator circuit breakers. Trip characteristics are often fully adjustable including configurable trip thresholds and delays. Usually electronically controlled, though some models are [[microprocessor]] controlled via an integral electronic trip unit. Often used for main power distribution in large industrial plant, where the breakers are arranged in draw-out enclosures for ease of maintenance. * [[Sulfur hexafluoride circuit breaker|SF<sub>6</sub> circuit breakers]] extinguish the arc in a chamber filled with [[sulfur hexafluoride]] gas. Medium-voltage circuit breakers may be connected into the circuit by bolted connections to bus bars or wires, especially in outdoor switchyards. Medium-voltage circuit breakers in switchgear line-ups are often built with draw-out construction, allowing breaker removal without disturbing power circuit connections, using a motor-operated or hand-cranked mechanism to separate the breaker from its enclosure. ===High-voltage=== <!--"Fiber optic current sensor" links here.--> {{Main|High-voltage switchgear}} [[File:Oil circuit breaker MKP-110 Toliatti Russia.jpg|thumb|left|Three single-phase Soviet/Russian 110-kV oil circuit breakers]] [[File:400kv.jpg|thumb|400 kV SF<sub>6</sub> live-tank circuit breakers]] Electrical [[power transmission]] networks are protected and controlled by high-voltage breakers. The definition of ''high voltage'' varies but in power transmission work is usually thought to be 72.5 kV or higher, according to a recent definition by the [[International Electrotechnical Commission]] (IEC). High-voltage breakers are nearly always [[solenoid]]-operated, with current sensing [[protective relay]]s operated through [[current transformer]]s. In [[electrical substation|substation]]s the protective relay scheme can be complex, protecting equipment and buses from various types of overload or ground/earth fault. High-voltage breakers are broadly classified by the medium used to extinguish the arc: * Bulk oil * Minimum oil * Air blast * [[Vacuum interrupter|Vacuum]] * [[Sulfur hexafluoride|SF<sub>6</sub>]] * [[Carbon dioxide|CO<sub>2</sub>]] Due to environmental and cost concerns over insulating oil spills, most new breakers use SF<sub>6</sub> gas to quench the arc. Circuit breakers can be classified as ''live tank'', where the enclosure that contains the breaking mechanism is at line potential, or ''dead tank'' with the enclosure at earth potential. High-voltage AC circuit breakers are routinely available with ratings up to 765 kV. 1,200{{nbsp}}kV breakers were launched by Siemens in November 2011,<ref>{{cite web|title=Siemens launches world's first 1200kV SF6 Circuit Breaker|url=http://www.indiainfoline.com/Markets/News/Siemens-launches-worlds-first-1200-kV-SF6-Circuit-Breaker/5286275764|access-date=14 November 2011|archive-date=3 July 2013|archive-url=https://web.archive.org/web/20130703122830/http://www.indiainfoline.com/Markets/News/Siemens-launches-worlds-first-1200-kV-SF6-Circuit-Breaker/5286275764|url-status=live}}</ref> followed by ABB in April the following year.<ref>{{cite news|title=ABB to develop ultra high voltage circuit breaker|newspaper=Utilities Middle East |date=16 April 2012 |url=http://www.utilities-me.com/article-1884-abb-to-develop-ultra-high-voltage-circuit-breaker/|access-date=14 August 2012|archive-date=4 March 2016|archive-url=https://web.archive.org/web/20160304041400/http://www.utilities-me.com/article-1884-abb-to-develop-ultra-high-voltage-circuit-breaker/|url-status=live}}</ref> High-voltage circuit breakers used on transmission systems may be arranged to allow a single pole of a three-phase line to trip, instead of tripping all three poles; for some classes of faults this improves the system stability and availability. [[High-voltage direct current]] circuit breakers are still a field of research as of 2015. Such breakers would be useful to interconnect HVDC transmission systems.<ref>{{cite web|title=High Voltage DC Switch Enables Supergrids for Renewable Energy, MIT Technology Review|url=http://www.technologyreview.com/featuredstory/513736/supergrids/|access-date=19 July 2013}}</ref> ===Sulfur hexafluoride (SF<sub>6</sub>) high-voltage=== {{Main|Sulfur hexafluoride circuit breaker}} A sulfur hexafluoride circuit breaker uses contacts surrounded by sulfur hexafluoride gas to quench the arc. They are most often used for transmission-level voltages and may be incorporated into compact gas-insulated switchgear. In cold climates, supplemental heating or different gas mixtures are used for high voltage circuit breakers, due to liquefaction of the SF<sub>6</sub> gas. In some northern power grids, gas mixtures of N<sub>2</sub> and SF<sub>6</sub>, or CF<sub>4</sub> and SF<sub>6</sub> are installed in puffer-type HVCB to quench the arc without any liquefaction of the gas. https://ieeexplore.ieee.org/abstract/document/4080767. The minimum temperature ratings of these models are as low as -50 °C for some northern substations. ===Disconnecting circuit breaker (DCB)=== <!--"Fiber optic current sensor" links here.--> <!--"Disconnector" links here.--> The disconnecting circuit breaker (DCB) was introduced in 2000<ref>{{cite web|title=Applications of Disconnecting Circuit Breakers, Michael Faxå, p.1 |url=http://www.labplan.ufsc.br/congressos/td2006/Papers/TD06_525.pdf |access-date=9 July 2012 |url-status=dead |archive-url=https://web.archive.org/web/20130516021322/http://www.labplan.ufsc.br/congressos/td2006/Papers/TD06_525.pdf |archive-date=16 May 2013 }}</ref> and is a high-voltage circuit breaker modeled after the SF<sub>6</sub>-breaker. It presents a technical solution where the disconnecting function is integrated in the breaking chamber, eliminating the need for separate disconnectors. This increases the [[availability]], since open-air disconnecting switch main contacts need maintenance every 2–6 years, while modern circuit breakers have maintenance intervals of 15 years. Implementing a DCB solution also reduces the space requirements within the substation, and increases the [[reliability engineering|reliability]], due to the lack of separate disconnectors.<ref>{{cite web|title=HPL Disconnecting Circuit Breaker|url=http://www.abb.com/product/db0003db002618/c12573e7003302adc1256e44006c19a3.aspx|access-date=9 July 2012|archive-date=20 February 2014|archive-url=https://web.archive.org/web/20140220183522/http://www.abb.com/product/db0003db002618/c12573e7003302adc1256e44006c19a3.aspx|url-status=live}}</ref><ref>{{cite web|title=Disconnecting Circuit Breakers, Buyer's and Application Guide, p. 10|url=https://www.cablejoints.co.uk/upload/DCB-Disconnecting-Circuit-Breakers---ABB-Buyers-and-Application-Guide.pdf|access-date=15 September 2014|archive-date=5 December 2020|archive-url=https://web.archive.org/web/20201205031237/https://www.cablejoints.co.uk/upload/DCB-Disconnecting-Circuit-Breakers---ABB-Buyers-and-Application-Guide.pdf|url-status=live}}</ref> In order to further reduce the required space of substation, as well as simplifying the design and engineering of the substation, a [[fiber optic current sensor]] (FOCS) can be integrated with the DCB. A 420 kV DCB with integrated FOCS can reduce a substation's [[ecological footprint|footprint]] with over 50% compared to a conventional solution of [[#High-voltage circuit breakers|live tank breakers]] with [[disconnector]]s and [[current transformer]]s, due to reduced material and no additional insulation medium.<ref>{{cite web|title= 362 – 550 kV Disconnecting Circuit Breaker with FOCS: Small, smart and flexible, p.1|url= http://search-ext.abb.com/library/Download.aspx?DocumentID=1HSM%209543%2021-10en&LanguageCode=en&DocumentPartId=&Action=Launch|access-date= 3 July 2013|archive-date= 11 May 2020|archive-url= https://web.archive.org/web/20200511213440/https://search-ext.abb.com/library/Download.aspx?DocumentID=1HSM%209543%2021-10en&LanguageCode=en&DocumentPartId=&Action=Launch|url-status= live}}</ref> ===Carbon dioxide (CO<sub>2</sub>) high-voltage=== In 2012, ABB presented a 75{{nbsp}}kV high-voltage breaker that uses carbon dioxide as the medium to extinguish the arc. The carbon dioxide breaker works on the same principles as an SF<sub>6</sub> breaker and can also be produced as a disconnecting circuit breaker. By switching from SF<sub>6</sub> to CO<sub>2</sub>, it is possible to reduce the CO<sub>2</sub> emissions by 10 tons during the product's life cycle.<ref>{{cite web |title= Switzerland: ABB breaks new ground with environment friendly high-voltage circuit breaker. |url= http://www.thefreelibrary.com/Switzerland+%3A+ABB+breaks+new+ground+with+environment+friendly...-a0300987882 |access-date= 7 June 2013 |archive-date= 24 December 2019 |archive-url= https://web.archive.org/web/20191224163718/https://www.thefreelibrary.com/Switzerland+:+ABB+breaks+new+ground+with+environment+friendly...-a0300987882 |url-status= live }}</ref> =="Smart" circuit breakers== Several firms have looked at adding monitoring for appliances via electronics or using a digital circuit breaker to monitor the breakers remotely. Utility companies in the United States have been reviewing use of the technology to turn appliances on and off, as well as potentially turning off charging of electric cars during periods of high electrical grid load. These devices under research and testing would have wireless capability to monitor the electrical usage in a house via a smartphone app or other means.<ref name=":0">{{Cite news|url=https://www.economist.com/news/science-and-technology/21731610-old-fuse-box-gets-new-lease-life-smart-circuit-breakers|title=Smart circuit-breakers for energy-efficient homes|newspaper=The Economist|access-date=2018-01-15|date=2017-11-23|archive-date=2018-01-15|archive-url=https://web.archive.org/web/20180115185945/https://www.economist.com/news/science-and-technology/21731610-old-fuse-box-gets-new-lease-life-smart-circuit-breakers|url-status=live}}</ref> ==Other breakers== [[File:ABB RCBO.jpg|thumb|[[Residual current circuit breaker]] with overcurrent protection]] The following types are described in separate articles. * Breakers for protections against earth faults too small to trip an over-current device: ** [[Residual-current device]] (RCD), or residual-current circuit breaker (RCCB) — detects current imbalance, but does not provide over-current protection. In the United States and Canada, these are called ground fault circuit interrupters (GFCI). ** Residual-current circuit breaker with overcurrent protection ([[RCBO]]) — combines the functions of a RCD and a MCB in one package. In the United States and Canada, these are called GFCI breakers. ** [[Earth leakage circuit breaker]] (ELCB) — This detects current in the earth wire directly rather than detecting imbalance. They are no longer seen in new installations as they cannot detect any dangerous condition where the current is returning to earth by another route{{dash}}such as via a person on the ground or via plumbing. (also called VOELCB in the UK). * [[Arc-fault circuit interrupter]] (AFCI) or arc-fault detection device (AFDD) — detects electric arcs from the likes of loose wires. * [[Recloser]] — A type of circuit breaker that closes automatically after a delay. These are used on overhead [[electric power distribution]] systems, to prevent short duration faults from causing sustained outages. * [[Polyswitch]] (polyfuse) — A small device commonly described as an automatically resetting fuse rather than a circuit breaker. ==See also== {{Portal|Electronics}} * [[Breaking capacity]] * [[Circuit breaker analyzer]] * [[Circuit total limitation]] (CTL) * [[Distribution board]] (Circuit breaker panel) * [[Earthing system]] * [[Ground Fault Circuit Interrupter]] (GFCI) * [[Hybrid switchgear module]] * [[Insulation monitoring device]] * [[Motor control center]] (MCC) * [[Network protector]] * [[Power distribution center]] (PDC) * [[Power system protection]] * [[Remote racking system]] * [[Ring Main Unit]] * [[Selectivity (circuit breakers)]] * [[Stab-Lok]]—a popular type of circuit breaker manufactured from 1950 to 1990, now widely deemed unsafe * [[Sulfur hexafluoride circuit breaker]] * [[Zener diode]]—a diode that allows current to flow in reverse direction (to break at certain level of voltage, an opposite effect) ==References== {{Reflist|30em}} ==Sources== * BS [[European Standard|EN]] 60898-1. Electrical accessories — Circuit breakers for over-current protection for household and similar installations. [[British Standards Institution]], 2003. ==External links== * [https://electricknowhow.com/course/transmission/hvac/substation/circuit-breaker-operation-and-maintenance/ Circuit Breaker] {{Webarchive|url=https://web.archive.org/web/20220927144809/https://electricknowhow.com/course/transmission/hvac/substation/circuit-breaker-operation-and-maintenance/ |date=2022-09-27 }} {{Electricity delivery}} {{Authority control}} {{DEFAULTSORT:Circuit Breaker}} [[Category:Electric power systems components]] [[Category:Electrical wiring]] [[Category:Over-current protection devices]] [[Category:20th-century inventions]] [[fi:Sulake#Palautettavia sulakkeita]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Authority control
(
edit
)
Template:Cite book
(
edit
)
Template:Cite journal
(
edit
)
Template:Cite news
(
edit
)
Template:Cite web
(
edit
)
Template:Convert
(
edit
)
Template:Dash
(
edit
)
Template:Dead link
(
edit
)
Template:Electrical wiring sidebar
(
edit
)
Template:Electricity delivery
(
edit
)
Template:For-multi
(
edit
)
Template:ISBN
(
edit
)
Template:Infobox electronic component
(
edit
)
Template:Main
(
edit
)
Template:Nbsp
(
edit
)
Template:Nowrap
(
edit
)
Template:Portal
(
edit
)
Template:Reflist
(
edit
)
Template:Short description
(
edit
)
Template:Spaces
(
edit
)
Template:Val
(
edit
)
Template:Var
(
edit
)
Template:Webarchive
(
edit
)