Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Particle-induced X-ray emission
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{short description|Non-destructive elemental analysis technique}} '''Particle-Induced X-Ray Emission''' or '''Proton-Induced X-Ray Emission''' ('''PIXE''') is a technique used for determining the [[Chemical element|element]]al composition of a [[material]] or a [[Sample size determination|sample]]. When a material is exposed to an [[ion]] beam, atomic interactions occur that give off [[EM radiation]] of [[wavelength]]s in the [[x-ray]] part of the [[electromagnetic spectrum]] specific to an element. PIXE is a powerful, yet non-destructive elemental analysis technique now used routinely by geologists, archaeologists, art conservators and others to help answer questions of provenance, dating and [[Authenticity in art|authenticity]]. The technique was first proposed in 1970 by Sven Johansson of [[Lund University]], [[Sweden]], and developed over the next few years with his colleagues Roland Akselsson and Thomas B Johansson.<ref>[https://web.archive.org/web/20070911094752/http://wwwold.eat.lth.se/Staff/Roland/RApers/Mini-cv.htm Roland Akselsson mini-CV]- accessed 2008-01-29</ref> Recent extensions of PIXE using tightly focused beams (down to 1 μm) gives the additional capability of [[Microscopy|microscopic analysis.]] This technique, called '''microPIXE''', can be used to determine the distribution of trace elements in a wide range of samples. A related technique, particle-induced gamma-ray emission (PIGE) can be used to detect some light elements. Additionally a multiplexed instrument combining PIXE with Mass Spectrometry of molecules: PDI-PIXE-MS or PIXE-MS. See below. == Theory == Three types of spectra can be collected from a PIXE experiment: # [[X-ray]] emission spectrum. # [[Rutherford backscattering]] spectrum. # Proton transmission spectrum. == X-ray emission == Quantum theory states that orbiting electrons of an atom must occupy discrete energy levels in order to be stable. Bombardment with ions of sufficient energy (usually MeV protons) produced by an ion accelerator, will cause inner shell ionization of atoms in a specimen. Outer shell electrons drop down to replace inner shell vacancies, however only certain transitions are allowed. X-rays of a characteristic energy of the element are emitted. An energy dispersive detector is used to record and measure these X-rays. Only elements heavier than fluorine can be detected. The lower detection limit for a PIXE beam is given by the ability of the X-rays to pass through the window between the chamber and the X-ray detector. The upper limit is given by the ionisation cross section, the probability of the K [[electron shell]] [[ionisation]], this is maximal when the velocity of the proton matches the velocity of the electron (10% of the [[speed of light]]), therefore 3 MeV proton beams are optimal. <ref>{{Cite journal |last=Ishii |first=K. |last2=Morita |first2=S. |date=August 1988 |title=Theoretical estimation of PIXE detection limits |url=https://linkinghub.elsevier.com/retrieve/pii/0168583X88907458 |journal=Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms |language=en |volume=34 |issue=2 |pages=209–216 |doi=10.1016/0168-583X(88)90745-8|url-access=subscription }}</ref> == Proton backscattering == Protons can also interact with the nucleus of the atoms in the sample through elastic collisions, [[Rutherford backscattering]], often repelling the proton at angles close to 180 degrees. The backscatter give information on the sample thickness and composition. The bulk sample properties allow for the correction of X-ray photon loss within the sample. == Proton transmission == The transmission of protons through a sample can also be used to get information about the sample. Channeling is one of the processes that can be used to study crystals. == Protein analysis == [[Protein]] analysis using microPIXE allow for the determination of the elemental composition of liquid and crystalline proteins. microPIXE can quantify the metal content of protein molecules with a relative accuracy of between 10% and 20%.<ref>{{cite journal|pmid=15910917|year=2005|last1=Garman|first1=EF|last2=Grime|first2=GW|title=Elemental analysis of proteins by microPIXE|volume=89|issue=2|pages=173–205|doi=10.1016/j.pbiomolbio.2004.09.005|journal=Progress in Biophysics and Molecular Biology|doi-access=}}</ref> The advantage of microPIXE is that given a protein of known sequence, the X-ray emission from [[sulfur]] can be used as an internal standard to calculate the number of metal atoms per protein monomer. Because only relative concentrations are calculated there are only minimal systematic errors, and the results are totally internally consistent. The relative concentrations of [[DNA]] to protein (and metals) can also be measured using the [[phosphate]] groups of the [[nucleotide|bases]] as an internal calibration. == Data analysis == Analysis of the data collected can be performed by the programs Dan32,<ref>Geoffrey W Grime Dan32: recent developments in the windows interface to gupix. Tenth International Conference on Particle Induced X-ray Emission, Portoroz, Slovenia, 2004</ref> the front end to gupix.<ref>{{cite journal|doi=10.1016/0168-583X(94)00540-0|title=The Guelph PIXE software package II|year=1995|last1=Maxwell|first1=J|last2=Teesdale|first2=W|last3=Campbell|first3=J|journal=Nuclear Instruments and Methods in Physics Research Section B|volume=95|issue=3|page=407|bibcode = 1995NIMPB..95..407M }}</ref><ref>{{cite journal|doi=10.1016/S0168-583X(00)00156-7|title=The Guelph PIXE software package III: Alternative proton database|year=2000|last1=Campbell|first1=J|journal=Nuclear Instruments and Methods in Physics Research Section B|volume=170|issue=1–2|page=193|bibcode = 2000NIMPB.170..193C }}</ref> == Limitations == In order to get a meaningful sulfur signal from the analysis, the buffer should not contain sulfur (i.e. no BES, [[DDT]], [[HEPES]], [[MES (buffer)|MES]], [[MOPS]]O or [[PIPES]] compounds). Excessive amounts of [[chlorine]] in the buffer should also be avoided, since this will overlap with the sulfur peak; [[Potassium bromide|KBr]] and [[Sodium bromide|NaBr]] are suitable alternatives. Due to the low penetration depth of protons and heavy charged particles, PIXE is limited to analyzing the top micrometer of a given sample. == Advantages == There are many advantages to using a proton beam over an electron beam. There is less crystal charging from [[Bremsstrahlung]] radiation, although there is some from the emission of [[Auger electron]]s, and there is significantly less than if the primary beam was itself an electron beam. Because of the higher mass of protons relative to electrons, there is less lateral deflection of the beam; this is important for [[proton beam writing]] applications. == Scanning == Two-dimensional maps of elemental compositions can be generated by scanning the microPIXE beam across the target. == Cell and Tissue Analysis == Whole cell and tissue analysis is possible using a microPIXE beam, this method is also referred to as [[nuclear microscopy]].<ref>{{cite journal |last1=Garman |first1=Elspeth |last2=Grime |first2=Geoffery |title=Elemental analysis of proteins by microPIXE |journal=Progress in Biophysics and Molecular Biology |date=October 2005 |volume=89 |issue=2 |pages=173–205 |doi=10.1016/j.pbiomolbio.2004.09.005 |pmid=15910917 |url=https://www.sciencedirect.com/science/article/pii/S0079610704001257 |access-date=25 June 2023|url-access=subscription }}</ref> == Artifact Analysis == MicroPIXE is a useful technique for the non-destructive analysis of paintings and antiques. Although it provides only an elemental analysis, it can be used to distinguish and measure layers within the thickness of an artifact.<ref>Grassi, N., et al. [http://pixe2004.ijs.si/abs/absPIXE2004229.html Differential PIXE measurements for the stratigraphic analysis of the painting “Madonna dei fusi”] 10th international PIXE conference (2004)- accessed 2008-01-29 {{webarchive |url=https://web.archive.org/web/20070908084337/http://pixe2004.ijs.si/abs/absPIXE2004229.html |date=September 8, 2007 }}</ref> The technique is comparable with destructive techniques such as the [[Inductively_coupled_plasma|ICP]] family of analyses. <ref>Ludovic Bellot-Gurlet et al [doi:10.1016/j.nimb.2005.06.216] "Obsidian provenance studies in archaeology: A comparison between PIXE, ICP-AES and ICP-MS", Nuclear Instruments and Methods in Physics Research B 240 (2005) 583–588, accessed 2021-06-20</ref> == Proton Beam Writing == Proton beams can be used for ''writing'' ([[proton beam writing]]) through either the hardening of a [[polymer]] (by proton induced [[cross-link]]ing), or through the degradation of a proton sensitive material. This may have important effects in the field of [[nanotechnology]]. == Particle Desorption Ionization Particle Induced X-ray Emission Mass Spectrometry PDI-PIXE-MS == This is a technique, PIXE-MS, for short, which combines PIXE with Mass Spectrometry of molecules. Elemental determinations are performed by PIXE with a heavy ion, such as oxygen, while simultaneously collecting the molecular ions for mass analysis in a quadrupole mass spectrometer, or time-of-flight (TOF) instrument.<ref><nowiki>https://www.researchgate.net/publication/386409748_ISBNpixemsdocx/stats</nowiki></ref> ICP-MS only determines elemental constituents using mass spectrometry, not molecular information. Sequential scanning may be done with a hydrogen ion beam and then a heavy ion beam to desorb and ionize the analyte sample. This technique allows for the analysis of both the elemental constituents as well as, simultaneously, the molecular ions, or molecular speciation, present in a sample, using a heavy ion beam. This makes use, typically, of a 4 MeV accelerator with samples prepared in glycerol, on carbon felt.<ref>https://www.researchgate.net/publication/359992537_PDI-PIXE-MS_Particle_Desorption_Ionization_Particle-Induced_X-Ray_Emission_Mass_Spectrometry</ref><ref>https://kynol.com/</ref> {{reflist}} ==External links== <references responsive="0" /> *{{usurped|1=[https://archive.today/20130416022259/http://www.universalleonardo.org/scientificAnalysis.php?tool=4917 Examination of Leonardo da Vinci's Madonna of the Yarnwinder using PIXE]}} *[http://repository.brynmawr.edu/lib_pubs/13/ Application of PIXE to the study of Renaissance style enameled gold jewelry] *https://www.researchgate.net/publication/359992537_PDI-PIXE-MS_Particle_Desorption_Ionization_Particle-Induced_X-Ray_Emission_Mass_Spectrometry *https://www.researchgate.net/publication/360804974_PIXEMS_PNNL031209_-_Pacific_Northwest_National_Laboratory_Presentation_-_Particle_Desorption_Ionization_Particle-Induced_X-Ray_Emission_Mass_Spectrometry_-_PDI-PIXE-MS *https://www.researchgate.net/publication/359992231_Sproch_N_Ashbaugh_MD_Morse_D_Grant_P_McIntyre_Jr_LC_Antolak_A_Fernando_Q_PDPIXE-MS_Particle_Desorption_Particle_Induced_X-ray_Emission_Mass_Spectrometry_Proceedings_of_the_49th_ASMS_Conference_on_Mass *https://kynol.com/ [[Category:Ion beam methods]] [[Category:Surface science]] [[Category:Experimental physics]] [[Category:Experimental particle physics]] [[Category:Nuclear physics]] [[Category:Particle physics]] [[Category:Protein methods]] [[Category:Emission spectroscopy]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Cite journal
(
edit
)
Template:Reflist
(
edit
)
Template:Short description
(
edit
)
Template:Usurped
(
edit
)
Template:Webarchive
(
edit
)