Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Plumbing fixture
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{Short description|Exchangeable device which can be connected to a plumbing system to deliver and drain water}} {{ref improve|date=November 2014}} A '''plumbing fixture''' is an exchangeable device which can be connected to a [[plumbing|plumbing system]] to [[water supply|deliver]] and [[sewerage|drain]] water. ==Common fixtures== ===Supply=== The most common plumbing fixtures are: *[[Bathtub]]s *[[Bidet]]s *[[Trench drain|Channel drains]] *[[Drinking fountain]]s *[[Shower]]s *[[Sink]]s *[[Hose bib|Tap]] (connections for water [[Hose (tubing)|hoses]]) **Tapware - an industry term for that sub-category of plumbing fixtures consisting of tap valves, also called water taps (British English) or faucets (American English), and their accessories, such as water spouts and shower heads. *Terminal [[valve]]s for dishwashers, ice makers, humidifiers, etc. *[[Urinal]]s *[[Toilets]] **[[Flush toilets]] ===Waste=== <!-- This section is linked from [[Irrigation tank]]. See [[WP:MOS#Section management]] --> [[Image:Water outlet russia.jpg|thumb|200px|A water outlet]] Each of these plumbing fixtures has one or more [[water]] outlets and a [[drain (plumbing)|drain]]. In some cases, the drain has a device that can be manipulated to block the drain to fill the basin of the fixture. Each fixture also has a ''flood rim'', or level at which water will begin to overflow. Most fixtures also have an overflow, which is a conduit for water to drain away, when the regular drain is plugged, before the water actually overflows at the flood rim level. However, water closets and [[showers]] (that are not in bathtubs) usually lack this feature because their drains normally cannot be stopped. Each fixture usually has a characteristic means of connection. Normal plumbing practice is to install a [[valve]] on each water supply line before the fixture, and this is most commonly termed a ''stop'' or "service valve". The water supply to some fixtures is cold water only (such as water closets and urinals). Most fixtures also have a hot water supply. In some occasional cases, a sink may have both a [[potable]] (drinkable) and a non-potable water supply. Lavatories and water closets normally connect to the water supply by means of a ''supply'', which is a tube, usually of nominal 3/8 in ([[United States]]) or 10 or 12 mm diameter ([[Europe]] and [[Middle East]]), which connects the water supply to the fixture, sometimes through a flexible ([[braid]]ed) hose. For water closets, this tube usually ends in a flat [[neoprene]] washer that tightens against the connection, while for lavatories, the supply usually ends in a [[conical]] neoprene washer. Kitchen sinks, tubs and showers usually have supply tubes built onto their valves which then are [[soldering|soldered]] or 'fast jointed' directly onto the water supply pipes. ====Drains==== The actual initial drain part in a lavatory or sink is termed a ''strainer''. If there is a removable strainer device that fits into the fixed strainer, it is termed a ''strainer basket''. The initial pipe that leads from the strainer to the trap is termed the ''tailpiece''. Floor-mounted water closets seal to the [[toilet flange]] of the drain pipe by means of a wax ring. These are traditionally made out of beeswax. However, their proper sealing depends on proper seating of the water closet, on a firm and secure base (floor), and on proper installation of the closet bolts which secure the closet to the flange, which is in turn supposed to be securely fastened to the floor.<ref>{{cite web |last1=Addison |first1=Riley |title=How to Move a Toilet Drain Pipe |url=https://plumbingadvice.online/how-to-move-a-toilet-drain-pipe/ |website=Plumbing Advice |publisher=Riley Addison |access-date=28 November 2024 }}</ref> ====Traps and vents==== [[Image:Drain cover with trap.jpg|thumb|350px|This drain cover has a container underneath (which can be taken out for cleaning and revealing another container below) acting as a trap. Water inside the container forms a seal when the cover is in place. Positive air pressure will push the cover up, acting as an early warning device. The underside of the cover (centre image) is kept moist by condensation occurring and insects that go back up the drain pipe get stuck to the walls of the cover.]] All plumbing fixtures have [[Trap (plumbing)|traps]] in their drains; these traps are either internal or external to the fixtures. Traps are pipes which curve down then back up; they "trap" a small amount of water to create a water seal between the ambient air space and the inside of the [[Plumbing drainage venting|drain system]]. This prevents [[sewer gas]] from entering buildings. Most water closets, bidets, and many urinals have the trap integral with the fixture itself. The visible water surface in a toilet is the top of the trap's water seal. Each fixture drain, with exceptions, must be vented so that negative air pressure in the drain cannot siphon the trap dry, to prevent positive air pressure in the [[sanitary sewer|sewer]] from forcing gases past the water seal, and to prevent [[methane|explosive sewer gas]] buildup. ==Electronic plumbing== [[Image:Plumbingsurveillancelightvectorpainting.jpg|thumb|right|Sensor operated plumbing fixtures have fewer moving parts, and therefore outlast traditional manual flush fixtures. Additionally, they reduce water consumption by way of intelligent flushing schedules (fuzzy logic) that determines the quantity of each flush based on how many people are standing in line to use the fixture.]] [[Image:Wall-mounted sloan valve shower sensor.jpg|thumb|A wall-mounted shower sensor]] In public facilities, the trend is toward sensor-operated (automatic) fixtures that improve hygiene and save money. For example, sensor operated automatic-flush urinals have fewer moving parts, reduce wear, and tend to last longer than manual-flush valves. Also, they ensure fixtures are flushed only once per use. Some contain intelligence that flushes them at different amounts of water flow depending on traffic patterns: e.g.'','' the fixture can detect a lineup of users and only give a full flush after the last person has used the urinal. For the same purpose, dual-[[flush toilet]]s are also becoming more popular. A combination of both technologies can allow for saved power and water. Automatic flush compensates for users who do not bother to flush. Also, since the fixtures are always flushed, there is no need for a [[urinal cake]], or other odor reduction. Sensor-operated toilets also have automatic flush. Sensor-operated faucets and showers save water. For example, while a user is lathering up with soap, the fixture shuts off and then resumes when the user needs it to. Sensor-operated soap and shampoo dispensers reduce waste and spills that might otherwise represent a slippage hazard. However, many people, especially children, dislike or even fear automatic flush toilets, since they have the tendency to flush without warning, even while the user is still sitting on the toilet. Some parents have started keeping track of public bathrooms that have manual flush toilets, or even carrying post-it notes or other devices with them to temporarily disable the automatic flush sensor.<ref>{{Cite news |last=Kelley |first=Tina |date=Nov 12, 2007 |title=For Children, a Scary World Out There (in There, Too) |language=en |work=The New York Times |url=https://www.nytimes.com/2007/11/12/nyregion/12flush.html |url-access=limited |access-date=2018-07-25}}</ref> These fixtures typically cost more to install than conventional plumbing fixtures, because they require the services (or presence) of both a licensed plumber and a licensed electrician. Construction companies on [[cost-plus contract]]s may actually favor these fixtures for this reason, although their clients may not. The additional complexity of these fixtures also complicates repairs, particularly the diagnosis of malfunctions causing unexpected flushing. Few electricians, and fewer plumbers, understand microelectronics well enough for complex diagnosis. ==Standardization== Some widely used standards for plumbing fittings and accessories located between the supply stop and the terminal fitting area are: * A112.18.1 Plumbing Supply Fittings Standard, [[American Society of Mechanical Engineers]] * A112.18.2 Plumbing Waste Fittings Standard, American Society of Mechanical Engineers ==See also== *[[Automatic balancing valve]] *[[Drain-waste-vent system]] *[[Plumbing]] *[[Tap water]] *[[Trap (plumbing)]] *[[Flushing trough]] ==References== <References/> {{Plumbing}} [[Category:Plumbing]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Cite news
(
edit
)
Template:Cite web
(
edit
)
Template:Plumbing
(
edit
)
Template:Ref improve
(
edit
)
Template:Short description
(
edit
)