Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Scintillation counter
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{short description|Instrument for measuring ionizing radiation}} [[File:PhotoMultiplierTubeAndScintillator.svg|400px|thumb|Schematic showing incident high energy photon hitting a scintillating crystal, triggering the release of low-energy [[photons]] which are then converted into [[photoelectrons]] and multiplied in the [[photomultiplier]]]] A '''scintillation counter''' is an instrument for detecting and measuring [[ionizing radiation]] by using the [[Electron excitation|excitation]] effect of incident radiation on a [[Scintillation (physics)|scintillating]] material, and detecting the resultant light pulses. It consists of a [[scintillator]] which generates photons in response to incident radiation, a sensitive [[photodetector]] (usually a [[photomultiplier]] tube (PMT), a [[charge-coupled device]] (CCD) camera, or a [[photodiode]]), which converts the light to an electrical signal and electronics to process this signal. Scintillation counters are widely used in radiation protection, assay of radioactive materials and physics research because they can be made inexpensively yet with good [[quantum efficiency]], and can measure both the intensity and the [[Electronvolt|energy]] of incident radiation. ==History== The first electronic scintillation counter was invented in 1944 by [[Samuel Curran|Sir Samuel Curran]]<ref>{{cite book |url=https://openlibrary.org/b/OL17868379M/Counting_tubes |title=Counting tubes, theory and applications |last=Curran |first=Samuel C. |publisher=Academic Press (New York) |date=1949 |pages=235 |ol=17868379M |language=en}}</ref><ref>[http://www.oxforddnb.com/view/article/69524 Oxford Dictionary of National Biography]</ref> whilst he was working on the [[Manhattan Project]] at the [[University of California at Berkeley]]. There was a requirement to measure the radiation from small quantities of uranium, and his innovation was to use one of the newly available highly sensitive [[photomultiplier]] tubes made by the [[Radio Corporation of America]] to accurately count the flashes of light from a scintillator subjected to radiation. This built upon the work of earlier researchers such as [[Antoine Henri Becquerel]], who discovered [[radioactivity]] whilst working on the [[phosphorescence]] of uranium salts in 1896. Previously, scintillation events had to be laboriously detected by eye, using a [[spinthariscope]] (a simple microscope) to observe light flashes in the scintillator. The first commercial liquid scintillation counter was made by Lyle E. Packard and sold to Argonne Cancer Research Hospital at the University of Chicago in 1953. The production model was designed especially for [[tritium]] and [[carbon-14]] which were used in metabolic studies ''[[in vivo]]'' and ''[[in vitro]]''.<ref>{{cite book |title=Instrumentation Between Science, State and Industry (Sociology of the Sciences Yearbook, 22) |last=Joerges |first=Bernward |publisher=Kluwer Academic Publishers |date=2001 |pages=270 |language=en}} {{ISBN|978-1402002427}}</ref> ==Operation== [[File:Scintillation Counter Schematic.jpg|right|300px|thumb|Apparatus with a scintillating crystal, [[photomultiplier]], and data acquisition components.]] [[File:Scintillation Detector.gif|thumb|animation of radiation scintillation counter using a photomultiplier tube.]] When an ionizing particle passes into the scintillator material, atoms are excited along a track. For charged particles the track is the path of the particle itself. For gamma rays (uncharged), their energy is converted to an energetic electron via either the [[photoelectric effect]], [[Compton scattering]] or [[pair production]]. The chemistry of atomic de-excitation in the scintillator produces a multitude of low-energy photons, typically near the blue end of the visible spectrum. The quantity is proportional to the energy deposited by the ionizing particle. These can be directed to the photocathode of a photomultiplier tube which emits at most one electron for each arriving photon due to the [[photoelectric effect]]. This group of primary electrons is electrostatically accelerated and focused by an electrical potential so that they strike the first dynode of the tube. The impact of a single electron on the dynode releases a number of secondary electrons which are in turn accelerated to strike the second dynode. Each subsequent dynode impact releases further electrons, and so there is a current amplifying effect at each dynode stage. Each stage is at a higher potential than the previous to provide the accelerating field. The resultant output signal at the anode is a measurable pulse for each group of photons from an original ionizing event in the scintillator that arrived at the photocathode and carries information about the energy of the original incident radiation. When it is fed to a [[charge amplifier]] which integrates the energy information, an output pulse is obtained which is proportional to the energy of the particle exciting the scintillator. The number of such pulses per unit time also gives information about the intensity of the radiation. In some applications individual pulses are not counted, but rather only the average current at the anode is used as a measure of radiation intensity. The scintillator must be shielded from all ambient light so that external photons do not swamp the ionization events caused by incident radiation. To achieve this a thin opaque foil, such as aluminized mylar, is often used, though it must have a low enough mass to minimize undue attenuation of the incident radiation being measured. The article on the [[photomultiplier]] tube carries a detailed description of the tube's operation. ==Detection materials== The scintillator consists of a transparent [[crystal]], usually a phosphor, plastic (usually containing [[anthracene]]) or [[organic liquid]] (see [[liquid scintillation counting]]) that fluoresces when struck by [[ionizing radiation]]. [[Cesium iodide]] (CsI) in crystalline form is used as the scintillator for the detection of protons and alpha particles. [[Sodium iodide]] (NaI) containing a small amount of [[thallium]] is used as a scintillator for the detection of gamma waves and [[zinc sulfide]] (ZnS) is widely used as a detector of alpha particles. [[Zinc sulfide]] is the material [[Rutherford scattering experiments|Rutherford]] used to perform his scattering experiment. [[Lithium iodide]] (LiI) is used in neutron detectors. ==Detector efficiencies== {{See also|Counting efficiency}} ===Gamma=== The quantum efficiency of a [[gamma ray|gamma-ray]] detector (per unit volume) depends upon the [[electron density|density]] of [[electron]]s in the detector, and certain scintillating materials, such as [[sodium iodide]] and [[bismuth germanate]], achieve high electron densities as a result of the high [[atomic number]]s of some of the elements of which they are composed. However, [[Semiconductor detector|detectors based on semiconductors]], notably hyperpure [[germanium]], have better intrinsic energy resolution than scintillators, and are preferred where feasible for [[Gamma spectroscopy|gamma-ray spectrometry]]. ===Neutron=== In the case of [[neutron]] detectors, high efficiency is gained through the use of scintillating materials rich in [[hydrogen]] that [[scattering theory|scatter]] neutrons efficiently. [[Liquid scintillation counting|Liquid scintillation counters]] are an efficient and practical means of quantifying [[beta particle|beta radiation]]. ==Applications== [[File:NNSA-NSO-1445.jpg|thumb|Scintillation probe being used to measure surface radioactive contamination. The probe is held as close to the object as practicable]] Scintillation counters are used to measure radiation in a variety of applications including hand held [[Survey meter|radiation survey meters]], personnel and [[environmental monitoring]] for [[radioactive contamination]], medical imaging, radiometric assay, nuclear security and nuclear plant safety. Several products have been introduced in the market utilising scintillation counters for detection of potentially dangerous gamma-emitting materials during transport. These include scintillation counters designed for freight terminals, border security, ports, weigh bridge applications, scrap metal yards and contamination monitoring of nuclear waste. There are variants of scintillation counters mounted on pick-up trucks and helicopters for rapid response in case of a security situation due to [[dirty bomb]]s or [[radioactive waste]].<ref>{{cite web|url=http://www.gammasonics.com/ardms.html|title=Automatic Radiation Detection and Monitoring System|archive-url=https://web.archive.org/web/20140814155457/http://www.gammasonics.com/ardms.html|archive-date=2014-08-14}}</ref>{{Failed verification|date=March 2015}}<ref>{{cite web|url=http://www.gammasonics.com/r2.html|title=Automatic Radiation Detection Vehicles|archive-url=https://web.archive.org/web/20140814155459/http://www.gammasonics.com/r2.html|archive-date=2014-08-14}}</ref>{{Failed verification|date=March 2015}} Hand-held units are also commonly used.<ref>[http://www.drct.com/survey_meters/MicroR_Meter.htm Portable MicroR Survey Meters] {{webarchive|url=https://web.archive.org/web/20091207201314/http://www.drct.com/survey_meters/MicroR_Meter.htm |date=2009-12-07 }}</ref> ===Diffusion cloud chamber === In the [[United Kingdom]], the [[Health and Safety Executive]], or HSE, has issued a user guidance note on selecting the correct radiation measurement instrument for the application concerned. This covers all radiation instrument technologies, and is a useful comparative guide to the use of scintillation detectors.<ref name = "ukhse">{{cite web |title=Selection, use and maintenance of portable monitoring instruments |url=http://www.hse.gov.uk/pubns/irp7.pdf |publisher=[[Health & Safety Executive]] |archive-url=https://web.archive.org/web/20121006055846/http://www.hse.gov.uk/pubns/irp7.pdf |archive-date=6 October 2012 |date=2001 |access-date=6 October 2012 |url-status=bot: unknown }}</ref> ==Radiation protection== ===Alpha and beta contamination=== [[File:US Navy 070208-N-9132D-002 Electronics Technician 2nd Class Shea Thompson tests an Alpha Particle Dection Probe.jpg|thumb|Hand-held large area alpha scintillation probe under calibration with a plate source in a bench calibration jig.]] [[File:Minamisoma Radiation 2011-11.jpg|thumb|Hand-held scintillation counter reading ambient gamma dose. The position of the internal detector is shown by the cross]] [[Radioactive contamination]] monitors, for area or personal surveys require a large detection area to ensure efficient and rapid coverage of monitored surfaces. For this a thin scintillator with a large area window and an integrated photomultiplier tube is ideally suited. They find wide application in the field of radioactive contamination monitoring of personnel and the environment. Detectors are designed to have one or two scintillation materials, depending on the application. "Single phosphor" detectors are used for either alpha or beta, and "Dual phosphor" detectors are used to detect both.<ref name = "knoll">Glenn F Knoll. Radiation Detection and Measurement, third edition 2000. John Wiley and sons, {{ISBN|0-471-07338-5}}</ref> A scintillator such as zinc sulphide is used for alpha particle detection, whilst plastic scintillators are used for beta detection. The resultant scintillation energies can be discriminated so that alpha and beta counts can be measured separately with the same detector,<ref name = "knoll" /> This technique is used in both hand-held and fixed monitoring equipment, and such instruments are relatively inexpensive compared with the gas proportional detector. ===Gamma=== Scintillation materials are used for ambient gamma dose measurement, though a different construction is used to detect contamination, as no thin window is required. ==As a spectrometer== {{main|Gamma spectroscopy}} [[File:Scintillation counter as a spectrometer.jpg|right|thumb|Measurement of gamma ray spectrum with a scintillation counter. A high voltage drives the counter which feeds signals to the Multichannel Analyser (MCA) and computer.]] Scintillators often convert a single [[photon]] of high energy [[radiation]] into a high number of lower-energy photons, where the number of photons per [[electronvolt|megaelectronvolt]] of input energy is fairly constant. By measuring the intensity of the flash (the number of the photons produced by the [[x-ray]] or gamma photon) it is therefore possible to discern the original photon's energy. The spectrometer consists of a suitable [[scintillator]] crystal, a [[photomultiplier]] tube, and a circuit for measuring the height of the pulses produced by the photomultiplier. The pulses are counted and sorted by their height, producing a x-y plot of scintillator flash [[brightness]] vs number of the flashes, which approximates the energy spectrum of the incident radiation, with some additional artifacts. A monochromatic gamma radiation produces a photopeak at its energy. The detector also shows response at the lower energies, caused by [[Compton scattering]], two smaller escape peaks at energies 0.511 and 1.022 MeV below the photopeak for the creation of electron-positron pairs when one or both annihilation photons escape, and a [[backscatter]] peak. Higher energies can be measured when two or more photons strike the detector almost simultaneously ([[pileup (disambiguation)|pile-up]], within the time resolution of the [[data acquisition]] chain), appearing as sum peaks with energies up to the value of two or more photopeaks added<ref name = "knoll" /> ==See also== * [[Gamma spectroscopy]] * [[Geiger counter]] * [[Liquid scintillation counting]] * [[Lucas cell]] * [[Pandemonium effect]] * [[Photon counting]] * [[Scintigraphy]] * [[Total absorption spectroscopy]] ==References== {{Commons category|Scintillation counter}} {{reflist}} {{Radiation protection|state=uncollapsed}} {{DEFAULTSORT:Scintillation Counter}} [[Category:Particle detectors]] [[Category:Spectrometers]] [[Category:Ionising radiation detectors]] [[Category:Radiation protection]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Cite book
(
edit
)
Template:Cite web
(
edit
)
Template:Commons category
(
edit
)
Template:Failed verification
(
edit
)
Template:ISBN
(
edit
)
Template:Main
(
edit
)
Template:Radiation protection
(
edit
)
Template:Reflist
(
edit
)
Template:See also
(
edit
)
Template:Short description
(
edit
)
Template:Sister project
(
edit
)
Template:Webarchive
(
edit
)