Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Sound intensity
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{Short description|Power carried by sound waves}} {{Sound measurements}} '''Sound intensity''', also known as '''acoustic intensity''', is defined as the power carried by sound waves per unit area in a direction perpendicular to that area, also called the '''[[sound power]] density''' and the '''sound energy flux density'''.{{Refn|[[IEC]] 801-21-38<ref>https://www.acoustic-glossary.co.uk/sound-energy.htm</ref>}} The [[International System of Units|SI unit]] of intensity, which includes sound intensity, is the [[watt]] per square meter (W/m<sup>2</sup>). One application is the noise measurement of sound [[intensity (physics)|intensity]] in the air at a listener's location as a sound energy quantity.<ref name="“GeorgiaStateUniversity">{{cite web|title=Sound Intensity|url=http://hyperphysics.phy-astr.gsu.edu/hbase/sound/intens.html|access-date=22 April 2015}}</ref> Sound intensity is not the same physical quantity as [[sound pressure]]. Human hearing is sensitive to sound pressure which is related to sound intensity. In consumer audio electronics, the level differences are called "intensity" differences, but sound intensity is a specifically defined quantity and cannot be sensed by a simple microphone. [[#Sound intensity level|Sound intensity level]] is a logarithmic expression of sound intensity relative to a reference intensity. ==Mathematical definition== Sound intensity, denoted '''I''', is defined by <math display="block">\mathbf I = p \mathbf v</math> where * ''p'' is the [[sound pressure]]; * '''v''' is the [[particle velocity]]. Both '''I''' and '''v''' are [[Vector (geometric)|vectors]], which means that both have a ''direction'' as well as a magnitude. The direction of sound intensity is the average direction in which energy is flowing. The average sound intensity during time ''T'' is given by <math display="block">\langle \mathbf I\rangle = \frac{1}{T} \int_0^T p(t) \mathbf v(t) \,\mathrm{d}t.</math> For a plane wave {{Citation needed|reason=This is a special case of the above expression, link to the derivation is needed|date=August 2022}}, <math display="block">\Iota = 2\pi^2\nu^2 \delta^2 \rho c</math> Where, * <math>\nu</math> is frequency of sound, * <math>\delta</math> is the amplitude of the sound wave [[particle displacement]], * <math>\rho</math> is density of medium in which sound is traveling, and * <math>c</math> is speed of sound. ==Inverse-square law== {{Further|Inverse-square law}} For a ''spherical'' sound wave, the intensity in the radial direction as a function of distance ''r'' from the centre of the sphere is given by <math display="block">I(r) = \frac{P}{A(r)} = \frac{P}{4 \pi r^2},</math> where * ''P'' is the [[sound power]]; * ''A''(''r'') is the [[Sphere#Surface area|surface area of a sphere]] of radius ''r''. Thus sound intensity decreases as 1/''r''<sup>2</sup> from the centre of the sphere: <math display="block">I(r) \propto \frac{1}{r^2}.</math> This relationship is an ''inverse-square law''. ==Sound intensity level== {{Other uses|Sound level (disambiguation){{!}}Sound level}} '''Sound intensity level''' (SIL) or '''acoustic intensity level''' is the [[level (logarithmic quantity)|level]] (a [[logarithmic quantity]]) of the intensity of a sound relative to a reference value. It is denoted ''L''<sub>''I''</sub>, expressed in [[neper]]s, [[Bel (unit)|bels]], or [[decibel]]s, and defined by<ref name=IEC60027-3>[http://webstore.iec.ch/webstore/webstore.nsf/artnum/028981 "Letter symbols to be used in electrical technology – Part 3: Logarithmic and related quantities, and their units"], ''IEC 60027-3 Ed. 3.0'', International Electrotechnical Commission, 19 July 2002.</ref> <math display="block">L_I = \frac{1}{2} \ln\left(\frac{I}{I_0}\right) \mathrm{Np} = \log_{10}\left(\frac{I}{I_0}\right)\mathrm{B} = 10 \log_{10}\left(\frac{I}{I_0}\right) \mathrm{dB},</math> where * ''I'' is the sound intensity; * ''I''<sub>0</sub> is the ''reference sound intensity''; ** {{no break|1=1 Np = 1}} is the [[neper]]; ** {{no break|1=1 B = {{sfrac|1|2}} ln(10)}} is the [[decibel|bel]]; ** {{no break|1=1 dB = {{sfrac|1|20}} ln(10)}} is the [[decibel]]. The commonly used reference sound intensity in air is<ref>Ross Roeser, Michael Valente, ''Audiology: Diagnosis'' (Thieme 2007), p. 240.</ref> <math display="block">I_0 = 1~\mathrm{pW/m^2}.</math> being approximately the lowest sound intensity hearable by an undamaged human ear under room conditions. The proper notations for sound intensity level using this reference are {{nobreak|''L''<sub>''I'' /(1 pW/m<sup>2</sup>)</sub>}} or {{nobreak|''L''<sub>''I''</sub> (re 1 pW/m<sup>2</sup>)}}, but the notations {{nobreak|dB SIL}}, {{nobreak|dB(SIL)}}, dBSIL, or dB<sub>SIL</sub> are very common, even if they are not accepted by the SI.<ref name=NIST2008>Thompson, A. and Taylor, B. N. sec 8.7, "Logarithmic quantities and units: level, neper, bel", ''Guide for the Use of the International System of Units (SI) 2008 Edition'', NIST Special Publication 811, 2nd printing (November 2008), SP811 [http://physics.nist.gov/cuu/pdf/sp811.pdf PDF]</ref> The reference sound intensity ''I''<sub>0</sub> is defined such that a progressive plane wave has the same value of sound intensity level (SIL) and [[sound pressure level]] (SPL), since <math display="block">I \propto p^2.</math> The equality of SIL and SPL requires that <math display="block">\frac{I}{I_0} = \frac{p^2}{p_0^2},</math> where {{nobreak|1=''p''<sub>0</sub> = 20 μPa}} is the reference sound pressure. For a ''progressive'' spherical wave, <math display="block">\frac{p}{c} = z_0,</math> where ''z''<sub>0</sub> is the [[Acoustic impedance#Characteristic specific acoustic impedance|characteristic specific acoustic impedance]]. Thus, <math display="block">I_0 = \frac{p_0^2 I}{p^2} = \frac{p_0^2 pc}{p^2} = \frac{p_0^2}{z_0}.</math> In air at ambient temperature, {{nobreak|1=''z''<sub>0</sub> = 410 Pa·s/m}}, hence the reference value {{nobreak|1=''I''<sub>0</sub> = 1 pW/m<sup>2</sup>}}.<ref>Sound Power Measurements, Hewlett Packard Application Note 1230, 1992.</ref> In an [[anechoic chamber]] which approximates a free field (no reflection) with a single source, measurements in the [[Near and far field|far field]] in SPL can be considered to be equal to measurements in SIL. This fact is exploited to measure sound power in anechoic conditions. ==Measurement== Sound intensity is defined as the time averaged product of sound pressure and acoustic particle velocity.<ref>{{Cite book | title=Sound Intensity| last=Fahy | first = Frank| date=2017 | publisher=CRC Press| isbn=978-1138474192|oclc=1008875245}}</ref> Both quantities can be directly measured by using a sound intensity ''p-u'' probe comprising a microphone and a [[Particle velocity probe|particle velocity sensor]], or estimated indirectly by using a ''p-p'' probe that approximates the particle velocity by integrating the pressure gradient between two closely spaced microphones.<ref>{{Cite book | title=Fundamentals of general linear acoustics | last=Jacobsen | first = Finn | isbn=9781118346419 | oclc=857650768 | date = 2013-07-29| publisher=Wiley }}</ref> Pressure-based measurement methods are widely used in anechoic conditions for noise quantification purposes. The bias error introduced by a ''p-p'' probe can be approximated by<ref name=":0">{{Cite journal |last1=Jacobsen|first1=Finn |last2=de Bree|first2=Hans-Elias |date=2005-09-01 |title=A comparison of two different sound intensity measurement principles |journal=The Journal of the Acoustical Society of America |volume=118 |issue=3 |pages=1510–1517 |doi=10.1121/1.1984860 |bibcode=2005ASAJ..118.1510J |s2cid=56449985 |issn=0001-4966 |url=https://backend.orbit.dtu.dk/ws/files/4449916/Jacobsen.pdf}}</ref> <math display="block">\widehat{I}^{p-p}_n \simeq I_n - \frac{\varphi_{\text{pe}}\,p_{\text{rms}}^2}{{k\Delta r \rho c}}=I_n \left( 1 - \frac{\varphi_{\text{pe}}}{k \Delta r} \frac{p_{\text{rms}}^2 / \rho c}{I_r}\right) ,</math> where <math>I_n</math> is the “true” intensity (unaffected by calibration errors), <math>\hat{I}^{p-p}_n</math> is the biased estimate obtained using a ''p-p'' probe, <math>p_{\text{rms}}</math> is the root-mean-squared value of the sound pressure, <math>k</math> is the wave number, <math>\rho</math> is the density of air, <math>c</math> is the speed of sound and <math>\Delta r</math> is the spacing between the two microphones. This expression shows that phase calibration errors are inversely proportional to frequency and microphone spacing and directly proportional to the ratio of the mean square sound pressure to the sound intensity. If the pressure-to-intensity ratio is large then even a small phase mismatch will lead to significant bias errors. In practice, sound intensity measurements cannot be performed accurately when the pressure-intensity index is high, which limits the use of ''p-p'' intensity probes in environments with high levels of background noise or reflections. On the other hand, the bias error introduced by a ''p-u'' probe can be approximated by<ref name=":0" /> <math display="block">\hat{I}^{p-u}_n = \frac{1}{2} \operatorname{Re}\left\{{P\hat{V}^*_n}\right\} = \frac{1}{2} \operatorname{Re}\left\{{P V^*_n e^{-j\varphi_{\text{ue}}} }\right\} \simeq I_n + \varphi_{\text{ue}} J_n \, ,</math> where <math>\hat{I}^{p-u}_n</math> is the biased estimate obtained using a ''p-u'' probe, <math>P</math> and <math>V_n</math> are the Fourier transform of sound pressure and particle velocity, <math>J_n </math> is the reactive intensity and <math>\varphi_{\text{ue}} </math> is the ''p-u'' phase mismatch introduced by calibration errors. Therefore, the phase calibration is critical when measurements are carried out under near field conditions, but not so relevant if the measurements are performed out in the far field.<ref name=":0" /> The “reactivity” (the ratio of the reactive to the active intensity) indicates whether this source of error is of concern or not. Compared to pressure-based probes, ''p-u'' intensity probes are unaffected by the pressure-to-intensity index, enabling the estimation of propagating acoustic energy in unfavorable testing environments provided that the distance to the sound source is sufficient. ==References== {{Reflist}} ==External links== *[http://www.sengpielaudio.com/RelationshipsOfAcousticQuantities.pdf Relationships of Acoustic Quantities Associated with a Plane Progressive Acoustic Sound Wave] *[http://www.sengpielaudio.com/TableOfSoundPressureLevels.htm Table of Sound Levels. Corresponding Sound Intensity and Sound Pressure] *[http://www.acoustical-consultants.com/noise-vibration-acoustical-related-resources/sound-intensity-noise-measurements/ What Is Sound Intensity Measurement and Analysis?] {{Authority control}} [[Category:Acoustics]] [[Category:Sound]] [[Category:Sound measurements]] [[Category:Physical quantities]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Authority control
(
edit
)
Template:Citation needed
(
edit
)
Template:Cite book
(
edit
)
Template:Cite journal
(
edit
)
Template:Cite web
(
edit
)
Template:Further
(
edit
)
Template:K\Delta r \rho c
(
edit
)
Template:No break
(
edit
)
Template:Nobreak
(
edit
)
Template:Other uses
(
edit
)
Template:Reflist
(
edit
)
Template:Refn
(
edit
)
Template:Short description
(
edit
)
Template:Sound measurements
(
edit
)