Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Spirometry
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{Short description|Pulmonary function test}} {{Use dmy dates|date=November 2019}} {{Infobox diagnostic | Name = Spirometry | Image = Flow-volume-loop.svg | Alt = | Caption = Flow-Volume loop showing successful FVC maneuver. Positive values represent expiration, negative values represent inspiration. At the start of the test both flow and volume are equal to zero (representing the volume in the spirometer rather than the lung). The trace moves clockwise for expiration followed by inspiration. After the starting point the curve rapidly mounts to a peak (the peak expiratory flow). (Note the FEV1 value is arbitrary in this graph and just shown for illustrative purposes; these values must be calculated as part of the procedure). | DiseasesDB = | ICD10 = | ICD9 = | ICDO = | MedlinePlus = | eMedicine = | MeshID = D013147 | LOINC = | HCPCSlevel2 = | OPS301 = {{OPS301|1-712}} | Reference_range = }} {{Pulmonary function}} [[File:DoingSpirometry.JPG|thumb|right|Doing spirometry]] '''Spirometry''' (meaning ''the measuring of breath'') is the most common of the [[pulmonary function test]]s (PFTs). It measures [[lung]] function, specifically the amount (volume) and/or speed (flow) of air that can be inhaled and exhaled. Spirometry is helpful in assessing breathing patterns that identify conditions such as [[asthma]], [[pulmonary fibrosis]], [[cystic fibrosis]], and [[Chronic obstructive pulmonary disease|COPD]]. It is also helpful as part of a system of [[Public health surveillance|health surveillance]], in which breathing patterns are measured over time.<ref>{{Cite web|url=https://www.cdc.gov/niosh/topics/spirometry/|title=Spirometry|website=[[National Institute for Occupational Safety and Health]] (NIOSH)|access-date=2017-01-31}}</ref> Spirometry generates pneumotachographs, which are charts that plot the volume and flow of air coming in and out of the lungs from one inhalation and one exhalation. ==Testing== {{unreferenced section|date=November 2019}} [[File:Spiro solo.jpg|thumb|left|A modern USB PC-based spirometer.]] [[File:Device for Spirometry or Body Plethysmography 02.jpg|thumb|left|Device for spirometry. The patient places his or her lips around the blue mouthpiece. The teeth go between the nubs and the shield, and the lips go over the shield. A nose clip guarantees that breath will flow only through the mouth.]] [[File:Body Plethysmography chamber 01.jpg|thumb|left|Screen for spirometry readouts at right. The chamber can also be used for body [[plethysmograph]]y.]] ===Spirometer=== The spirometry test is performed using a device called a [[spirometer]],<ref>{{cite web | title = Spirometry | publisher = Cleveland Clinic | url = https://my.clevelandclinic.org/health/diagnostics/17833-spirometry| access-date = 13 Sep 2020}}</ref> which comes in several different varieties. Most spirometers display the following graphs, called spirograms: * a ''volume-time curve'', showing volume (litres) along the Y-axis and time (seconds) along the X-axis * a ''flow-volume loop'', which graphically depicts the rate of airflow on the Y-axis and the total volume [[inhalation|inspired]] or [[exhalation|expired]] on the X-axis ===Procedure=== The basic forced volume vital capacity (FVC) test varies slightly depending on the equipment used. It can be in the form of either closed or open circuit. Regardless of differences in testing procedure providers are recommended to follow the [https://www.thoracic.org/statements/resources/pfet/PFT2.pdf ATS/ERS Standardisation of Spirometry]. The standard procedure ensures an accurate and objectively collected set of data, based on a common reference, to reduce incompatibility of the results when shared across differing medical groups. The patient is asked to put on soft nose clips to prevent air escape and a breathing sensor in their mouth forming an air tight seal. Guided by a technician, the patient is given step by step instructions to take an abrupt maximum effort inhale, followed by a maximum effort exhale lasting for a target of at least 6 seconds. When assessing possible [[upper airway obstruction]], the technician will direct the patient to make an additional rapid inhalation to complete the round. The timing of the second inhale can vary between persons depending on the length of the proceeding exhale. In some cases each round of test will be proceeded by a period of normal, gentle breathing for additional data. ===Limitations=== Clinically useful results are highly dependent on patient cooperation and effort and must be repeated for a minimum of three times to ensure [[reproducibility]] with a general limit of ten attempts. Given variable rates of effort, the results can only be underestimated given an effort output greater than 100% is not possible.{{Citation needed|reason=Second sentence is making a medical determination so it should be cited to ensure correctness of the underestimated statement. It was also reworded to reduce confusion, but this tag should at minimum serve to notify reader of a potential discrepancy.|date=July 2023}} Due to the need for patient cooperation and an ability to understand and follow instructions, spirometry can typically only be done in cooperative children when they at least 5 years old<ref>{{cite book |doi=10.1016/B978-0-12-417044-5.00054-8 |chapter=Outcome Measures in Neuromuscular Diseases |title=Neuromuscular Disorders of Infancy, Childhood, and Adolescence |date=2015 |last1=Montes |first1=Jacqueline |last2=Kaufmann |first2=Petra |pages=1078β1089 |isbn=978-0-12-417044-5 }}</ref><ref>{{Cite web |last=Pruthi, M.D. |first=Sandhya |date=January 6, 2022 |title=Asthma: Steps in testing and diagnosis |url=https://www.mayoclinic.org/diseases-conditions/asthma/in-depth/asthma/art-20045198 |access-date=July 14, 2023 |website=[[Mayo Clinic]]}}</ref> or adults without physical or mental impairment preventing effective diagnostic results. In addition, [[General anesthesia]] and various forms of sedation are not compatible with the testing process. Another limitation is that persons with intermittent or mild asthma can present normal spirometry values between acute exacerbation, reducing spirometry's effectiveness as a diagnostic tool in these circumstances.{{Citation needed|reason=this is making a medical determination so it should be cited to ensure correctness. It was also reworded to reduce confusion, but this tag should at minimum serve to notify reader of a potential discrepancy.|date=July 2023}} ===Supplemental diagnostics=== Spirometry can also be part of a [[bronchial challenge test]], used to determine [[bronchial]] hyperresponsiveness to either rigorous exercise, inhalation of cold/dry air, or with a pharmaceutical agent such as [[methacholine]] or [[histamine]]. To assess the reversibility of a particular condition, a [[bronchodilator]] can be administered before performing another round of tests for comparison. This is commonly referred to as a ''reversibility test'', or a ''[[post bronchodilator test]]'' (Post BD), and is an important part in diagnosing asthma versus COPD. Other complementary lung functions tests include [[plethysmography]] and [[nitrogen washout]]. ===Indications=== Spirometry is indicated for the following reasons: * to diagnose or manage asthma<ref name="AAAAIfive">{{cite web |author1 = American Academy of Allergy, Asthma, and Immunology |author1-link = American Academy of Allergy, Asthma, and Immunology |title = Five Things Physicians and Patients Should Question |publisher = [[American Academy of Allergy, Asthma, and Immunology]] |work = Choosing Wisely: an initiative of the [[ABIM Foundation]] |url = http://choosingwisely.org/wp-content/uploads/2012/04/5things_12_factsheet_AAAAI.pdf |access-date = 14 August 2012}}</ref><ref name="NIHasthmaguide">{{cite book|title=Expert Panel Report 3: Guidelines for the Diagnosis and Management of Asthma|year=2007|publisher=National Institutes of Health|url=http://www.nhlbi.nih.gov/guidelines/asthma/asthgdln.pdf|edition=NIH Publication Number 08-5846}}</ref><ref name="globalstrategy">{{cite journal | last1 = Bateman | first1 = E. D. | last2 = Hurd | first2 = S. S. | last3 = Barnes | first3 = P. J. | last4 = Bousquet | first4 = J. | last5 = Drazen | first5 = J. M. | last6 = Fitzgerald | first6 = M. | last7 = Gibson | first7 = P. | last8 = Ohta | first8 = K. | last9 = O'Byrne | first9 = P. | last10 = Pedersen | first10 = S. E. | last11 = Pizzichini | first11 = E. | last12 = Sullivan | first12 = S. D. | last13 = Wenzel | first13 = S. E. | last14 = Zar | first14 = H. J. | title = Global strategy for asthma management and prevention: GINA executive summary | journal = European Respiratory Journal | volume = 31 | issue = 1 | pages = 143β178 | year = 2008 | pmid = 18166595 | doi = 10.1183/09031936.00138707 | s2cid = 206960094 | doi-access = free }}</ref> * to detect respiratory disease in patients presenting with symptoms of breathlessness, and to distinguish respiratory from [[cardiac disease]] as the cause<ref name="essentialspirometry">{{Cite journal | last1 = Pierce | first1 = R. | title = Spirometry: An essential clinical measurement | journal = Australian Family Physician | volume = 34 | issue = 7 | pages = 535β539 | year = 2005 | pmid = 15999163}}</ref> * to measure bronchial responsiveness in patients suspected of having asthma<ref name="essentialspirometry"/> * to diagnose and differentiate between [[obstructive lung disease]] and [[restrictive lung disease]]<ref name="essentialspirometry"/> * to follow the [[natural history of disease]] in respiratory conditions<ref name="essentialspirometry"/> * to assess of impairment from [[occupational asthma]]<ref name="essentialspirometry"/> * to identify those at risk from pulmonary [[barotrauma]] while [[scuba diving]]<ref name="essentialspirometry"/> * to conduct pre-operative risk assessment before anaesthesia or [[cardiothoracic surgery]]<ref name="essentialspirometry"/> * to measure response to treatment of conditions which spirometry detects<ref name="essentialspirometry"/> * to diagnose the [[vocal cord dysfunction]]. ===Contraindications=== Forced expiratory maneuvers may aggravate some medical conditions.<ref>{{cite book|last1=Clark|first1=Margaret Varnell|title=Asthma: A Clinician's Guide |url=https://archive.org/details/asthmaclinicians00clar|url-access=limited|date=2010|publisher=Jones & Bartlett Learning|location=Burlington, Ma.|isbn=978-0763778545|page=[https://archive.org/details/asthmaclinicians00clar/page/n62 46]|edition=ist}}</ref> Spirometry should not be performed when the individual presents with: * [[Hemoptysis]] of unknown origin * [[Pneumothorax]] * Unstable cardiovascular status ([[angina]], recent [[myocardial infarction]], etc.) * Thoracic, abdominal, or cerebral [[aneurysms]] * [[Cataracts]] or recent eye surgery * Recent thoracic or abdominal surgery * [[Nausea]], [[vomiting]], or acute illness * Recent or current viral infection * Undiagnosed [[hypertension]] ==Parameters== The most common parameters measured in spirometry are vital capacity (VC), forced vital capacity (FVC), forced expiratory volume (FEV) at timed intervals of 0.5, 1.0 (FEV1), 2.0, and 3.0 seconds, forced expiratory flow 25β75% (FEF 25β75) and maximal voluntary ventilation (MVV),<ref>[http://www.surgeryencyclopedia.com/Pa-St/Spirometry-Tests.html surgeryencyclopedia.com > Spirometry tests]. Retrieved 14 March 2010.</ref> also known as Maximum breathing capacity.<ref>[http://www.biology-online.org/dictionary/Maximum_breathing_capacity MVV and MBC]</ref> Other tests may be performed in certain situations. Results are usually given in both raw data (litres, litres per second) and percent predictedβthe test result as a percent of the "predicted values" for the patients of similar characteristics (height, age, sex, and sometimes race and weight). The interpretation of the results can vary depending on the physician and the source of the predicted values. Generally speaking, results nearest to 100% predicted are the most normal, and results over 80% are often considered normal. Multiple publications of predicted values have been published and may be calculated based on age, sex, weight and ethnicity. However, review by a doctor is necessary for accurate diagnosis of any individual situation. A bronchodilator is also given in certain circumstances and a pre/post graph comparison is done to assess the effectiveness of the bronchodilator. See the example printout. [[Functional residual capacity]] (FRC) cannot be measured via spirometry, but it can be measured with a [[plethysmograph]] or dilution tests (for example, helium dilution test). [[File:Normal values for FVC, FEV1 and FEF 25-75.png|thumb|220px|left|Average values for forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1) and forced expiratory flow 25β75% (FEF25β75%), according to a study in the United States 2007 of 3,600 subjects aged 4β80 years.<ref>{{cite journal |vauthors=Stanojevic S, Wade A, Stocks J, etal |title=Reference Ranges for Spirometry Across All Ages: A New Approach |journal=Am. J. Respir. Crit. Care Med. |volume=177 |issue=3 |pages=253β60 |date=February 2008 |pmid=18006882 |pmc=2643211 |doi=10.1164/rccm.200708-1248OC }}</ref> Y-axis is expressed in litres for FVC and FEV1, and in litres/second for FEF25β75%.]] [[Image:LungVolume.jpg|frameless|600px|Output of a 'spirometer']] ===Forced vital capacity (FVC)=== Forced [[vital capacity]] (FVC) is the volume of air that can forcibly be blown out after full inspiration,<ref name="Office">{{Cite journal|last1=Perez|first1=LL|title=Office spirometry|journal= Osteopathic Family Physician |volume=5 |issue=2 |pages=65β69 |date=MarchβApril 2013|doi =10.1016/j.osfp.2012.09.003}}</ref> measured in liters. FVC is the most basic maneuver in spirometry tests. ===Forced expiratory volume in 1 second (FEV1)=== FEV1 is the volume of air that can forcibly be blown out in first 1-second, after full inspiration.<ref name="Office"/> Average values for FEV1 in healthy people depend mainly on sex and age, according to the diagram. Values of between 80% and 120% of the average value are considered normal.<ref name=uppsala>LUNGFUNKTION β Practice compendium for semester 6. Department of Medical Sciences, Clinical Physiology, Academic Hospital, Uppsala, Sweden. Retrieved 2010.</ref> Predicted normal values for FEV1 can be calculated and depend on age, sex, height, mass and ethnicity as well as the research study that they are based on. ===FEV1/FVC ratio=== [[FEV1/FVC ratio|FEV1/FVC]] is the ratio of FEV1 to FVC. In healthy adults this should be approximately 70β80% (declining with age).<ref>{{cite book|last1=Clinic|first1=the Cleveland|title=Current clinical medicine 2010|date=2010|publisher=Saunders|location=Philadelphia, Pa.|isbn=978-1416066439|page=8|edition=2nd}}</ref> In obstructive diseases (asthma, COPD, chronic bronchitis, emphysema) FEV1 is diminished because of increased airway resistance to expiratory flow; the FVC may be decreased as well, due to the premature closure of airway in expiration, just not in the same proportion as FEV1 (for instance, both FEV1 and FVC are reduced, but the former is more affected because of the increased airway resistance). This generates a reduced value (<70%, often ~45%). In restrictive diseases (such as [[pulmonary fibrosis]]) the FEV1 and FVC are both reduced proportionally and the value may be normal or even increased as a result of decreased lung compliance. A derived value of FEV1 is '''FEV1% predicted''' (FEV1%), which is defined as FEV1 of the patient divided by the average FEV1 in the population for any person of the same age, height, gender, and race.{{medcn|date=November 2019}} ===Forced expiratory flow (FEF)=== Forced expiratory flow (FEF) is the flow (or speed) of air coming out of the lung during the middle portion of a forced expiration. It can be given at [[discrete time]]s, generally defined by what fraction of the forced vital capacity (FVC) has been exhaled. The usual discrete intervals are 25%, 50% and 75% (FEF25, FEF50 and FEF75), or 25% and 50% of FVC that has been exhaled. It can also be given as a mean of the flow during an interval, also generally delimited by when specific fractions remain of FVC, usually 25β75% (FEF25β75%). Average ranges in the healthy population depend mainly on sex and age, with FEF25β75% shown in diagram at left. Values ranging from 50 to 60% and up to 130% of the average are considered normal.<ref name=uppsala/> Predicted normal values for FEF can be calculated and depend on age, sex, height, mass and ethnicity as well as the research study that they are based on. '''MMEF''' or '''MEF''' stands for maximal (mid-)expiratory flow and is the peak of expiratory flow as taken from the flow-volume curve and measured in liters per second. It should theoretically be identical to [[peak expiratory flow]] (PEF), which is, however, generally measured by a peak flow meter and given in liters per minute.<ref name=hedenstrom2009>Interpretation model β compendium at Uppsala Academic Hospital. By H. HedenstrΓΆm. 2009-02-04</ref> Recent research suggests that FEF25-75% or FEF25-50% may be a more sensitive parameter than FEV1 in the detection of obstructive small airway disease.<ref>{{cite journal|last1=Simon|first1=Michael R.|last2=Chinchilli|first2=Vernon M.|last3=Phillips|first3=Brenda R.|last4=Sorkness|first4=Christine A.|last5=Lemanske Jr.|first5=Robert F.|last6=Szefler|first6=Stanley J.|last7=Taussig|first7=Lynn|last8=Bacharier|first8=Leonard B.|last9=Morgan|first9=Wayne|title=Forced expiratory flow between 25% and 75% of vital capacity and FEV1/forced vital capacity ratio in relation to clinical and physiological parameters in asthmatic children with normal FEV1 values|journal=Journal of Allergy and Clinical Immunology|date=1 September 2010|volume=126|issue=3|pages=527β534.e8|doi=10.1016/j.jaci.2010.05.016|pmid=20638110|pmc=2933964}}</ref><ref>{{cite journal|last=Ciprandi|first=Giorgio|author2=Cirillo, Ignazio |title=Forced expiratory flow between 25% and 75% of vital capacity may be a marker of bronchial impairment in allergic rhinitis|journal=Journal of Allergy and Clinical Immunology|date=1 February 2011|volume=127|issue=2|pages=549; discussion 550β1|doi=10.1016/j.jaci.2010.10.053|pmid=21281879}}</ref> However, in the absence of concomitant changes in the standard markers, discrepancies in mid-range expiratory flow may not be specific enough to be useful, and current practice guidelines recommend continuing to use FEV1, VC, and FEV1/VC as indicators of obstructive disease.<ref>{{cite journal |vauthors=Pellegrino R, Viegi G, Brusasco V, Crapo RO, Burgos F, Casaburi R, Coates A, van der Grinten CP, Gustafsson P, Hankinson J, Jensen R, Johnson DC, MacIntyre N, McKay R, Miller MR, Navajas D, Pedersen OF, Wanger J | title = Interpretative strategies for lung function tests | journal = The European Respiratory Journal | volume = 26 | issue = 5 | pages = 948β68 | date = November 2005 | pmid = 16264058 | doi = 10.1183/09031936.05.00035205 | s2cid = 2741306 | doi-access = free }}</ref><ref name="ACP Medicine">{{cite web|last=Kreider|first=Maryl|title=Chapter 14.1 Pulmonary Function Testing|url=http://online.statref.com/Notes/ResolveNote.aspx?NoteID=48177&grpalias=TEX|website=ACP Medicine|publisher=Decker Intellectual Properties|access-date=29 April 2011}}</ref> More rarely, forced expiratory flow may be given at intervals defined by how much remains of total lung capacity. In such cases, it is usually designated as e.g. FEF70%TLC, FEF60%TLC and FEF50%TLC.<ref name=hedenstrom2009/> ===Forced inspiratory flow 25β75% or 25β50%=== Forced inspiratory flow 25β75% or 25β50% (FIF 25β75% or 25β50%) is similar to FEF 25β75% or 25β50% except the measurement is taken during inspiration.{{medcn|date=November 2019}} ===Peak expiratory flow (PEF)=== [[File:Normal values for peak expiratory flow - EU scale.svg|thumb|right|250px|Normal values for peak expiratory flow (PEF), shown on EU scale.<ref>{{cite journal |vauthors=Nunn AJ, Gregg I |title=New regression equations for predicting peak expiratory flow in adults |journal=BMJ |volume=298 |issue=6680 |pages=1068β70 |date=April 1989 |pmid=2497892 |pmc=1836460 |doi=10.1136/bmj.298.6680.1068}} Adapted by Clement Clarke for use in EU scale β see [http://www.peakflow.com/top_nav/normal_values/index.html Peakflow.com β Predictive Normal Values (Nomogram, EU scale)]</ref>]] [[Peak expiratory flow]] (PEF) is the maximal flow (or speed) achieved during the maximally forced expiration initiated at full inspiration, measured in liters per minute or in liters per second. ===Tidal volume (TV)=== [[Tidal volume]] is the amount of air inhaled or exhaled normally at rest.{{medcn|date=November 2019}} ===Total lung capacity (TLC)=== [[Total lung capacity]] (TLC) is the maximum volume of air present in the lungs.{{medcn|date=November 2019}} ===Diffusing capacity (DLCO)=== [[Diffusion capacity|Diffusing capacity]] (or [[DLCO]]) is the carbon monoxide uptake from a single inspiration in a standard time (usually 10 seconds). During the test the person inhales a test gas mixture that consisting of regular air that includes an inert [[tracer gas]] and CO, less than one percent. Since hemoglobin has a greater affinity to CO than oxygen the breath-hold time can be only 10 seconds, which is a sufficient amount of time for this transfer of CO to occur. Since the inhaled amount of CO is known, the exhaled CO is subtracted to determine the amount transferred during the breath-hold time. The tracer gas is analyzed simultaneously with CO to determine the distribution of the test gas mixture. This test will pick up diffusion impairments, for instance in pulmonary fibrosis.<ref>{{MedlinePlusEncyclopedia|003854|Lung diffusion testing}}</ref> This must be corrected for anemia (a low hemoglobin concentration will reduce DLCO) and pulmonary hemorrhage (excess RBC's in the interstitium or alveoli can absorb CO and artificially increase the DLCO capacity). Atmospheric pressure and/or altitude will also affect measured DLCO, and so a correction factor is needed to adjust for standard pressure. ===Maximum voluntary ventilation (MVV)=== <!--target for redirect [[Maximum voluntart ventilation]] --> Maximum voluntary ventilation (MVV) is a measure of the maximum amount of air that can be inhaled and exhaled within one minute. For the comfort of the patient this is done over a 15-second time period before being extrapolated to a value for one minute expressed as liters/minute. Average values for males and females are 140β180 and 80β120 liters per minute respectively.{{medcn|date=November 2019}} ===Static lung compliance (C<sub>st</sub>)=== When estimating static lung compliance, volume measurements by the spirometer needs to be complemented by [[pressure transducer]]s in order to simultaneously measure the [[transpulmonary pressure]]. When having drawn a curve with the relations between changes in volume to changes in transpulmonary pressure, C<sub>st</sub> is the slope of the curve during any given volume, or, mathematically, ΞV/ΞP.<ref name=Ronald>{{cite book |first=Ronald B. |last=George |title=Chest medicine: essentials of pulmonary and critical care medicine |year=2005 |publisher=Lippincott Williams & Wilkins |isbn=978-0-7817-5273-2 |page=96 }}</ref> Static lung compliance is perhaps the most sensitive parameter for the detection of abnormal pulmonary mechanics.<ref>{{cite journal | last1 = Sud | first1 = A. | last2 = Gupta | first2 = D. | last3 = Wanchu | first3 = A. | last4 = Jindal | first4 = S. K. | last5 = Bambery | first5 = P. | title = Static lung compliance as an index of early pulmonary disease in systemic sclerosis | journal = Clinical Rheumatology | volume = 20 | issue = 3 | pages = 177β180 | year = 2001 | pmid = 11434468 | doi = 10.1007/s100670170060 | s2cid = 19170708 }}</ref> It is considered normal if it is 60% to 140% of the average value in the population for any person of similar age, sex and body composition.<ref name=uppsala/> In those with acute respiratory failure on mechanical ventilation, "the static compliance of the total respiratory system is conventionally obtained by dividing the tidal volume by the difference between the 'plateau' pressure measured at the airway opening (PaO) during an occlusion at end-inspiration and positive end-expiratory pressure (PEEP) set by the ventilator".<ref>{{cite journal |last1=Rossi |first1=A. |last2=Gottfried |first2=S. B. |last3=Zocchi |first3=L. |last4=Higgs |first4=B. D. |last5=Lennox |first5=S. |last6=Calverley |first6=P. M. |last7=Begin |first7=P. |last8=Grassino |first8=A. |last9=Milic-Emili |first9=J. |title=Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation. The effect of intrinsic positive end-expiratory pressure |journal=The American Review of Respiratory Disease |date=May 1985 |volume=131 |issue=5 |pages=672β677 |doi=10.1164/arrd.1985.131.5.672 |doi-broken-date=1 November 2024 |pmid=4003913 }}</ref> {| class="wikitable" |rowspan=2| '''Measurement''' ||colspan=2| '''Approximate value''' |- | '''Male''' || '''Female''' |- | '''Forced vital capacity''' (FVC) || 4.8 L || 3.7 L |- | '''Tidal volume''' (Vt) || 500 mL || 390 mL |- | '''Total lung capacity''' (TLC) || 6.0 L || 4.7 L |- |} ===Others=== '''Forced Expiratory Time (FET)'''<br> Forced Expiratory Time (FET) measures the length of the expiration in seconds. '''Slow vital capacity (SVC)'''<br> Slow [[vital capacity]] (SVC) is the maximum volume of air that can be exhaled slowly after slow maximum inhalation. '''Maximal pressure (P<sub>max</sub>''' and '''P<sub>i</sub>''') {| class="wikitable" | colspan="2" |Spirometer - ERV in cc (cm<sup>3</sup>) average Age 20 |- |Male |Female |- |4320 |3387 |} <br> P<sub>max</sub> is the asymptotically maximal pressure that can be developed by the respiratory muscles at any lung volume and P<sub>i</sub> is the maximum inspiratory pressure that can be developed at specific lung volumes.<ref>{{cite journal |last1=Lausted |first1=Christopher G |last2=Johnson |first2=Arthur T |last3=Scott |first3=William H |last4=Johnson |first4=Monique M |last5=Coyne |first5=Karen M |last6=Coursey |first6=Derya C |title=Maximum static inspiratory and expiratory pressures with different lung volumes |journal=BioMedical Engineering OnLine |date=December 2006 |volume=5 |issue=1 |page=29 |doi=10.1186/1475-925X-5-29 |pmid=16677384 |pmc=1501025 |doi-access=free }}</ref> This measurement also requires pressure transducers in addition. It is considered normal if it is 60% to 140% of the average value in the population for any person of similar age, sex and body composition.<ref name="uppsala" /> A derived parameter is the '''coefficient of retraction (CR)''' which is P<sub>max</sub>/TLC .<ref name="hedenstrom2009" /> '''Mean transit time (MTT)'''<br> Mean transit time is the area under the flow-volume curve divided by the forced vital capacity.<ref>{{cite journal | last1 = Borth | first1 = F. M. | title = The derivation of an index of ventilatory function from spirometric recordings using canonical analysis | journal = British Journal of Diseases of the Chest | volume = 76 | issue = 4 | pages = 400β756 | year = 1982 | doi = 10.1016/0007-0971(82)90077-8 | pmid = 7150499 | doi-access = free }}</ref> {{anchor|Maximal inspiratory pressure}} '''Maximal inspiratory pressure (MIP)''' MIP, also known as '''negative inspiratory force (NIF)''', is the maximum pressure that can be generated against an occluded airway beginning at functional residual capacity (FRC). It is a marker of respiratory muscle function and strength.<ref>[https://books.google.com/books?id=JL3ZwUaO0zkC&pg=PA352 Page 352] in: {{cite book | last = Irwin | first = Richard | title = Procedures, techniques, and minimally invasive monitoring in intensive care medicine | publisher = Wolters Kluwer Health/Lippincott Williams & Wilkins | location = Philadelphia | year = 2008 | isbn = 978-0-7817-7862-6 }}</ref> Represented by centimeters of water pressure (cmH2O) and measured with a [[manometer]]. Maximum inspiratory pressure is an important and noninvasive index of [[Thoracic diaphragm|diaphragm]] strength and an independent tool for diagnosing many illnesses.<ref name="pmid19796411">{{cite journal| author=Sachs MC, Enright PL, Hinckley Stukovsky KD, Jiang R, Barr RG, Multi-Ethnic Study of Atherosclerosis Lung Study| title=Performance of maximum inspiratory pressure tests and maximum inspiratory pressure reference equations for 4 race/ethnic groups | journal=Respir Care | year= 2009 | volume= 54 | issue= 10 | pages= 1321β8 | pmid=19796411 | pmc= 3616895}}</ref> Typical maximum inspiratory pressures in adult males can be estimated from the equation, M<sub>IP</sub> = 142 - (1.03 x Age) cmH<sub>2</sub>O, where age is in years.<ref>{{cite journal |vauthors=Wilson SH, Cooke NT, Edwards RH, Spiro SG |title=Predicted normal values for maximal respiratory pressures in caucasian adults and children |journal=Thorax |volume=39 |issue=7 |pages=535β8 |date=July 1984 |pmid=6463933 |pmc=459855 |doi=10.1136/thx.39.7.535 }}</ref> ==Technologies used in spirometers== * '''Volumetric Spirometers''' ** Water bell ** [[Bellows]] wedge * '''Flow measuring Spirometers''' ** Fleisch-pneumotach ** Lilly (screen) pneumotach ** [[Turbine]]/Stator Rotor (normally incorrectly referred to as a turbine. Actually a rotating vane which spins because of the air flow generated by the subject. The revolutions of the vane are counted as they break a light beam) ** [[Pitot tube]] ** Hot-wire [[anemometer]] ** [[Ultrasonic flow meter|Ultrasound]] == See also == * [[Anaesthesiology]] * [[Peak flow meter]] * [[Nitrogen washout]] == References == {{reflist}} ==Further reading== * {{cite journal |vauthors=Miller MR, Crapo R, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, Enright P, van der Grinten CP, Gustafsson P, Jensen R, Johnson DC, MacIntyre N, McKay R, Navajas D, Pedersen OF, Pellegrino R, Viegi G, Wanger J | title = General considerations for lung function testing | journal = European Respiratory Journal | volume = 26 | issue = 1 | pages = 153β161 | date = July 2005 | pmid = 15994402 | doi = 10.1183/09031936.05.00034505 | s2cid = 5626417 | doi-access = free }} ==External links== {{Commons category|Spirometry}} * [http://www.thoracic.org/ American Thoracic Society] (ATS) * [http://ersnet.org/ers/ European Respiratory Society] (ERS) {{Respiratory physiology}} {{Respiratory system procedures}} [[Category:Pulmonary function testing]] [[Category:Respiratory physiology]] [[Category:Respiratory therapy]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Anchor
(
edit
)
Template:Citation needed
(
edit
)
Template:Cite book
(
edit
)
Template:Cite journal
(
edit
)
Template:Cite web
(
edit
)
Template:Commons category
(
edit
)
Template:Infobox diagnostic
(
edit
)
Template:Medcn
(
edit
)
Template:MedlinePlusEncyclopedia
(
edit
)
Template:Pulmonary function
(
edit
)
Template:Reflist
(
edit
)
Template:Respiratory physiology
(
edit
)
Template:Respiratory system procedures
(
edit
)
Template:Short description
(
edit
)
Template:Unreferenced section
(
edit
)
Template:Use dmy dates
(
edit
)