Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Utility pole
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{short description|Post used by public utilities to support overhead wires and related equipment}} {{Use dmy dates|date=January 2025}} [[File:SIF-Overhead-Wires-1-Cropped.jpg|thumb|right|Utility pole supporting wires for electrical power distribution, [[coaxial cable]] for [[cable television]], and telephone cable. A pair of [[Shoe tossing|shoes]] can be seen hanging from the wires (center-left, far right)]] A '''utility pole''', commonly referred to as a '''transmission pole''', '''telephone pole''', '''telecommunication pole''', '''power pole''', '''hydro pole''', '''telegraph pole''', or '''telegraph post''', is a [[column]] or post used to support [[overhead power line]]s and various other public utilities, such as [[electrical cable]], [[optical fiber|fiber optic cable]], and related equipment such as [[Distribution transformer|transformers]] and [[street light]]s while depending on its application. They are used for two different types of power lines: ''sub transmission lines'', which carry higher voltage power between substations, and ''distribution lines'', which distribute lower voltage power to customers. Electrical wires and cables are routed overhead on utility poles as an inexpensive way to keep them insulated from the ground and out of the way of people and vehicles.<ref>{{Cite web |date=2020-07-17 |title=Why are overhead transmission lines not insulated? |url=https://www.electricalclassroom.com/why-are-overhead-transmission-lines-not-insulated/ |access-date=2024-02-21 |website=www.electricalclassroom.com |language=en-us}}</ref> Utility poles are usually made out of [[wood]], [[Aluminium alloy|aluminum alloy]],<ref>{{Cite web |title=Choosing the Right Materials for Pole Upgrades |url=https://utilitiesone.com/choosing-the-right-materials-for-pole-upgrades |access-date=2024-02-21 |website=Utilities One |language=en |archive-url=https://web.archive.org/web/20240221105837/https://utilitiesone.com/choosing-the-right-materials-for-pole-upgrades |archive-date=2024-02-21 |url-status=dead}}</ref> metal, concrete, or composites like [[fiberglass]]. A [[Stobie pole]] is a multi-purpose pole made of two steel joists held apart by a slab of concrete in the middle, generally found in [[South Australia]]. The first poles were used in 1843 by telegraph pioneer [[William Fothergill Cooke]], who used them on a line along the [[Great Western Railway]]. Utility poles were first used in the mid-19th century in America with [[telegraph]] systems, starting with [[Samuel Morse]], who attempted to bury a line between [[Baltimore]] and [[Washington, D.C.]], but moved it above ground when this system proved faulty. Today, underground distribution lines are increasingly used as an alternative to utility poles in residential neighborhoods, due to poles' perceived ugliness, as well as safety concerns in areas with large amounts of snow or ice build up. They have also been suggested in areas prone to hurricanes and blizzards as a way to reduce power outages.<ref>{{Cite web |title=After Fiona, PEI utility says it's exploring ways to bury residential power lines |url=https://atlantic.ctvnews.ca/after-fiona-p-e-i-utility-says-it-s-exploring-ways-to-bury-residential-power-lines-1.6132822 |access-date=2025-01-05}}</ref> [[File:Aerial Work Platforms - Japan - 2012.ogv|thumb|(video) Three [[aerial work platform]] trucks work together on utility poles, in [[Bunkyō]], Japan]] ==Use== [[File:Hv braunschweig20.jpg|thumb|Wooden electricity poles in Germany. In central Europe, lines usually run just straight across fields, rows of poles accompanying roads are quite rare.]] Utility poles are commonly used to carry two types of electric [[Electric power transmission|power lines]]:<ref name="Grigsby">{{cite book|last=Grigsby|first=Leonard L.|title=The Electric Power Engineering Handbook|publisher=CRC Press|year=2001|location=USA|url=https://books.google.com/books?id=wiv1tuMDbTEC&q=%22utility+transformer%22&pg=PT1346|isbn=0-8493-8578-4|url-status=live|archive-url=https://web.archive.org/web/20160428033235/https://books.google.com/books?id=wiv1tuMDbTEC&pg=PT1346&lpg=PT1346&dq=%22utility+transformer%22&source=web&ots=XwZnFMsRK8&sig=68TttGd59rC3_TstnrUd8hvXUHI&hl=en&sa=X&oi=book_result&resnum=5&ct=result#PPT385,M1|archive-date=2016-04-28}}</ref> ''[[Electric power distribution|distribution lines]]'' (or "feeders") and ''sub transmission lines''. Distribution lines carry power from local [[Electrical substation|substations]] to customers. They generally carry voltages from 4.6 to 33 [[volt|kilovolts]] (kV) for distances up to {{cvt|30|mi|-1}}, and include transformers to step the voltage down from the primary voltage to the lower secondary voltage used by the customer. A [[service drop]] carries this lower voltage to the customer's premises. Subtransmission lines carry higher voltage power from regional substations to local substations. They usually carry 46 kV, 69 kV, or 115 kV for distances up to {{cvt|60|mi|-1}}. 230 kV lines are often supported on H-shaped towers made with two or three poles. [[Transmission line]]s carrying voltages of above 230 kV are usually not supported by poles, but by metal pylons (known as [[transmission tower]]s in the US). For economic or practical reasons, such as to save space in urban areas, a distribution line is often carried on the same poles as a sub transmission line but mounted under the higher voltage lines; a practice called "underbuild". Telecommunication cables are usually carried on the same poles that support power lines; poles shared in this fashion are known as joint-use poles, but may have their own dedicated poles. ==Description== [[File:Old steel pole - Gryfow 3.jpg|thumb|upright=0.7|Steel utility pole for low voltage in [[Gryfów]], Poland]] The standard utility pole in the United States is about {{cvt|35|ft|-1}} tall and is buried about {{cvt|6|ft|0}} in the ground.<ref name="Florida">{{cite web|url=http://www.psc.state.fl.us/ConsumerAssistance/UtilityPoleDescriptions|title=What's on a utility pole?|year=2008|publisher=Florida Public Service Commission|archive-url=https://web.archive.org/web/20160225175755/http://www.psc.state.fl.us/ConsumerAssistance/UtilityPoleDescriptions|archive-date=2016-02-25|url-status=live|work=Consumer Assistance|access-date=2008-10-24}}</ref> In order to meet clearance regulations, poles can, however, reach heights of at least 120 feet (40 meters). They are typically spaced about {{cvt|125|ft|-1}} apart in urban areas, or about {{cvt|300|ft|-2}} in rural areas, but distances vary widely based on terrain. Joint-use poles are usually owned by one utility, which leases space on it for other cables. In the United States, the [[National Electrical Safety Code]], published by the [[Institute of Electrical and Electronics Engineers]] (IEEE) (not to be confused with the [[National Electrical Code]] published by the [[National Fire Protection Association]] [NFPA]), sets the standards for construction and maintenance of utility poles and their equipment. ===Pole materials=== Most utility poles are made of wood, pressure-treated with some type of [[Wood preservation|preservative]] for protection against rot, fungi and insects. [[Southern yellow pine]] is the most widely used species in the United States; however, many species of long straight trees are used to make utility poles, including [[Douglas fir]], [[jack pine]], [[Pinus contorta|lodgepole pine]], [[Thuja plicata|western red cedar]], and [[Abies amabilis|Pacific silver fir]]. Traditionally, the preservative used was [[creosote]], but due to environmental concerns, alternatives such as [[pentachlorophenol]], copper [[naphthenic acid|naphthenate]] and [[borate]]s are becoming widespread in the United States. In the United States, standards for wood preservative materials and wood preservation processes, along with test criteria, are set by [[American National Standards Institute|ANSI]], [[ASTM International|ASTM]], and [[Wood preservation#American Wood Protection Association|American Wood Protection Association]] (AWPA) specifications. Despite the preservatives, wood poles decay and have a life of approximately 25 to 50 years depending on climate and soil conditions, therefore requiring regular inspection and remedial preservative treatments.<ref>{{cite web|url=http://www.pmcpole.com/cms/AWPA_poleMaintenance_paper.pdf|title=PMCPOLE.COM|website=www.pmcpole.com|url-status=live|archive-url=https://web.archive.org/web/20110715094205/http://www.pmcpole.com/cms/AWPA_poleMaintenance_paper.pdf|archive-date=2011-07-15}}</ref><ref>{{cite web|url=http://www.pmcpole.com/cms/groundlineTreatmentSP.pdf|title=PMCPOLE.COM|website=www.pmcpole.com|url-status=live|archive-url=https://web.archive.org/web/20090114191254/http://www.pmcpole.com/cms/groundlineTreatmentSP.pdf|archive-date=2009-01-14}}</ref><ref>{{cite web|url=http://www.pmcpole.com/cms/rus_bulletin_1730B_121.pdf|title=PMCPOLE.COM|website=www.pmcpole.com|url-status=live|archive-url=https://web.archive.org/web/20090114191256/http://www.pmcpole.com/cms/rus_bulletin_1730B_121.pdf|archive-date=2009-01-14}}</ref> [[Woodpecker]] damage to wood poles is the most significant cause of pole deterioration in some parts of the U.S.<ref>{{cite web |last1=Harness |first1=Rick |title=Raptor Electrocutions and Distribution Pole Types |url=https://web.archive.org/web/20160315140750/http://volgabirds.ru/user_files/ikar/TechBulletin_0ct_00.pdf |website=Volga Birds |publisher=North American Wood Pole Coalition |access-date=16 April 2025}}</ref> Other common utility pole materials are aluminum, steel and concrete, with composites (such as [[fiberglass]]{{citation needed|date=May 2020}}) also becoming more prevalent.<ref>{{Cite journal |last1=Rasheed |first1=Rizwan |last2=Javed |first2=Hajra |last3=Rizwan |first3=Asfra |last4=Afzaal |first4=Muhammad |last5=Ahmad |first5=Sajid Rashid |date=April 2023 |title=Eco-sustainability analysis of precast-concrete utility poles manufacturing–A case study from Pakistan |url=|journal=Heliyon |volume=9 |issue=4 |pages=e14976 |doi=10.1016/j.heliyon.2023.e14976 |doi-access=free |issn=2405-8440 |pmc=10121627 |pmid=37095914|bibcode=2023Heliy...914976R }}</ref> One particular [[patent]]ed utility pole variant used in Australia is the [[Stobie pole]], made up of two vertical steel posts with a slab of concrete between them. ===Power distribution wires and equipment=== [[File:US utility pole - labeled.jpg|thumb|upright=1.1|Typical North American utility pole, showing hardware for a residential 240/120 V split-phase [[service drop]]: <span style="color:red;">(''A'',''B'',''C'')</span> 3-phase primary distribution wires (mounted on a crossarm), <span style="color:red;">(''D'')</span> neutral wire, <span style="color:red;">(''E'')</span> [[fuse cutout]], <span style="color:red;">(''F'')</span> [[lightning arrester]], <span style="color:red;">(''G'')</span> single-phase distribution transformer, <span style="color:red;">(''H'')</span> ground wire to transformer case, <span style="color:red;">(''J'')</span> "triplex" service drop cable carries secondary current to customer, <span style="color:red;">(''K'')</span> telephone and cable television cables ]] On poles carrying both electrical and communications wiring, the electric [[overhead power line|power distribution lines]] and associated equipment are mounted at the top of the pole above the communication cables, for safety. The vertical space on the pole reserved for this equipment is called the ''supply space''.<ref name="Florida" /> The wires themselves are usually uninsulated, and supported by [[insulator (electricity)|insulators]], commonly mounted on a horizontal beam ('''{{vanchor|Crossarm|text=crossarm}}'''). Power is transmitted using the [[three-phase electric power|three-phase]] system, with three wires, or phases, labeled "A", "B", and "C". Sub transmission lines comprise only these 3 wires, plus sometimes an overhead ground wire (OGW), also called a "static line" or a "neutral", suspended above them. The OGW acts like a lightning rod, providing a low [[Electrical resistance and conductance|resistance]] path to ground thus protecting the phase conductors from lightning. [[File:China utility pole.jpg|thumb|left|A joint-use utility pole in China]] Distribution lines use two systems, either grounded-wye ("Y" on [[Circuit diagram|electrical schematics]]) or delta (Greek letter [[Delta (letter)|"Δ"]] on electrical schematics). A delta system requires only a conductor for each of the three phases. A grounded-wye system requires a fourth conductor, the [[Ground and neutral|neutral]], whose source is the center of the "Y" and is grounded. However, "spur lines" branching off the main line to provide power to side streets often carry only one or two phase wires, plus the neutral. A wide range of standard distribution voltages are used, from 2,400 V to 34,500 V. On poles near a [[service drop]], there is a pole-mounted step-down [[distribution transformer]] to transform the high distribution voltage to the lower secondary voltage provided to the customer. In [[North America]], service drops provide 240/120 V [[Split-phase electric power|split-phase]] power for residential and light commercial service, using cylindrical single-phase transformers. In Europe and most other countries, 230 V [[three phase]] (230Y400) service drops are used. The transformer's primary is connected to the distribution line through protective devices called [[fuse cutout]]s. In the event of an overload, the fuse melts and the device pivots open to provide a visual indication of the problem. They can also be opened manually by [[lineman (technician)|linemen]] using a long insulated rod called a [[hot stick]] to disconnect the transformer from the line. The pole may be [[ground (electricity)|grounded]] with a heavy bare [[copper]] or [[copper-clad steel]] wire running down the pole, attached to the metal pin supporting each insulator, and at the bottom connected to a metal rod driven into the ground. Some countries ground every pole while others only ground every fifth pole and any pole with a transformer on it. This provides a path for leakage currents across the surface of the insulators to get to ground, preventing the current from flowing through the wooden pole which could cause a fire or shock hazard.<ref name="Grigsby"/><ref name="Florida"/> It provides similar protection in case of [[flashover]]s and lightning strikes. A [[surge arrester]] (also called a lightning arrester) may also be installed between the line (ahead of the cutout) and the ground wire for lightning protection. The purpose of the device is to conduct extremely high voltages present on the line directly to ground. If uninsulated conductors touch due to wind or fallen trees, the resultant sparks can start [[wildfire]]s. To reduce this problem, [[Aerial bundled cable|aerial bundled conductors]] are being introduced. ===Communication cables=== The communications cables are attached below the electric power lines, in a vertical space along the pole designated the ''communications space''.<ref name="Florida" /> The communications space is separated from the lowest electrical conductor by the ''communication worker safety zone'', which provides room for workers to maneuver safely while servicing the communication cables, avoiding contact with the power lines.<ref name="Florida"/> The most common communication cables found on utility poles are copper or [[fibre-optic cable]] (FOC) for [[telephone lines]] and [[coaxial cable]] for [[cable television]] (CATV). Coaxial or optical fibre cables linking [[computer networks]] are also increasingly found on poles in urban areas. The cable linking the [[telephone exchange]] to local customers is a thick cable lashed to a thin supporting cable, containing hundreds of [[twisted pair]] [[subscriber line]]s. Each twisted pair line provides a single telephone circuit or [[local loop]] to a customer. There may also be FOCs interconnecting telephone exchanges. Like electrical distribution lines, communication cables connect to service drops when used to provide local service to customers. ===Other equipment=== Utility poles may also carry other equipment such as [[street light]]s, supports for [[traffic light]]s and [[Overhead line|overhead wires]] for [[electric trolley]]s, and [[cellular network]] antennas. They can also carry fixtures and decorations specific for certain holidays or events specific to the city where they are located. Solar panels mounted on utility poles may power auxiliary equipment where the expense of a power line connection is unwanted. Streetlights and holiday fixtures are powered directly from secondary distribution. ==Pole attachment hardware== [[File:American telephone practice (1905) (14753288101).jpg|thumb|left|Standard arrangement for telephone poles]] The primary purpose of pole attachment hardware is to secure the cable and associated aerial plant facilities to poles and to help facilitate necessary plant rearrangements. An aerial plant network requires high-quality reliable hardware to *Structurally support the distribution cable plant *Provide directional guying to accommodate lateral stresses created on the pole by pole line configurations and pole loading configuration *Provide the physical support and protection for drop cable plant from the pole to the customer premises *Transition cable plant from the aerial network to underground and buried plant *Provide the means for safe and effective grounding, bonding, and isolation connections for the metallic and dielectric components of the network. Functional performance requirements common to pole line hardware for utility poles made of wood, steel, concrete, or Fiber-Reinforced Composite (FRC) materials are contained in Telcordia GR-3174, ''Generic Requirements for Hardware Attachments for Utility Poles''.<ref>[http://telecom-info.njdepot.ericsson.net/site-cgi/ido/docs.cgi?ID=SEARCH&DOCUMENT=GR-3174& GR-3174, ''Generic Requirements for Hardware Attachments for Utility Poles'']</ref> === Attachment hardware by pole type === *'''Wood poles''' [[File:Palo_SES_Tegna_260513.jpg|thumb|Head of a 400 V pole in Switzerland. In Europe, insulators usually were attached directly at the pole.]] :The traditional wood pole material provides great flexibility during placement of hardware and cable apparatus. Holes are easily drilled to fit the exact hardware needs and requirements. In addition, fasteners such as lags and screws are easily applied to wood structures to support [[outside plant]] (OSP) apparatus. *'''Non-wood poles''' :There are three main non-wood pole materials and structures on which the attachment hardware may be mounted: concrete, steel, and fiber-reinforced composite (FRC). Each material has intrinsic characteristics that need to be considered during the design and manufacture of the attachment hardware. :*'''Concrete poles''' [[File:Several power pole made of concrete, in Iran 2017 -- چند تیر برق بتنی در ایران.jpg|thumb|Several power poles made of concrete]] ::The most widespread use of concrete poles is in [[Oceanic climate|marine environments]] and coastal zones where excellent corrosion resistance is required to reduce the impact of sea water, salt fog, and corrosive soil conditions (e.g., marsh). Their heavy weight also helps the concrete poles resist the high winds possible in coastal areas. ::The various designs for concrete poles include tapered structures and round poles made of solid concrete; pre-stressed concrete (spun-cast or statically cast); and a hybrid of concrete and steel. ::The drilling of installed concrete poles is not feasible. Users may wish to have the attachment hardware cast into the concrete during the pole manufacture. As a result of these operational difficulties, banded hardware has become the more popular means to attach cable plant to concrete poles. ::Design criteria and requirements for concrete poles can be derived from various industry documents including, but not limited to, ASCE-111, ACI-318, ASTM C935, and ASTM C1089. :*'''Steel poles''' [[File:Views of Candaba Viaduct Apalit Bypass Road fields 10.jpg|thumb|Steel poles of Hermosa–Duhat–Balintawak 230,000 volt transmission line along [[Candaba Viaduct]] of [[North Luzon Expressway]] (NLEx) in [[Apalit]], [[Pampanga]].]] ::Steel poles can provide advantages for high-voltage lines, where taller poles are required for enhanced clearances and longer span requirements. Tubular steel poles are typically made from 11-gauge galvanized steel, with thicker 10- or 7-gauge materials used for some taller poles because of their higher strength and rigidity. For tall tower-type structures, 5-gauge materials are used. ::Although steel poles can be drilled on-site with an [[Annular cutter|annular]] drill bit or standard twist drill, it is not a recommended practice. As with concrete poles, bolt holes could be built into the steel pole during manufacture for use as general attachment points or places for steps to be bolted into the pole. ::Welding of attachment hardware or attachment ledges to steel poles may be a feasible alternate approach to help provide reliable attachment points. However, operational and practical hazards of welding in the field may make this process undesirable or uneconomical. ::Steel poles should meet industry specifications such as: TIA/EIA-222-G, ''Structural Standard for Antenna Supporting Structures and Antennas'' (current); TIA/EIA-222; ''Structural Standards for Steel''; and TIA/EIA-RS-222, or an equivalent requirement set to help ensure a robust and good quality pole is being used. :*'''Fiber-reinforced composite (FRC) poles''' ::FRC poles cover a family of pole materials that combine fiberglass (fiber) strength members with a cross-linked polyester resin and a variety of chemical additives to produce a lightweight, weather-resistant structure. FRC poles are hollow and similar to the tubular steel poles, with a typical wall thickness of {{cvt|1/4|to|1/2|in|mm|0}} with an outer polyurethane coating that is ~{{cvt|0.002|in|mm|2}} thin. ::As with all the other non-wood poles, FRC poles cannot be mounted with the traditional climbing hardware of hooks and gaffs. FRC poles can be pre-drilled by the manufacturer, or holes can be drilled on site. Attachments using lag bolts, teeth, nails, and staples are unacceptable for FRC poles. Through-bolts are used instead of lag bolts for maximum bonding to the pole and to avoid loosening of hardware. ::The relevant industry documents covering FRC poles include: ASTM D4923, ANSI C136.20, OPCS-03-02, and Telcordia GR-3159, ''Generic Requirements for Fiber-Reinforced Composite (FRC), Concrete, and Steel Utility Poles''.<ref>[http://telecom-info.njdepot.ericsson.net/site-cgi/ido/docs.cgi?ID=SEARCH&DOCUMENT=GR-3159& GR-3159, ''Generic Requirements for Fiber-Reinforced Composite (FRC), Concrete, and Steel Utility Poles'']</ref> ==Access== [[File:Telephone Pole Orchard? (28776548771).jpg|thumb|Pre-apprentice lineman class climbing telephone poles]] In some countries, such as the United Kingdom, utility poles have sets of brackets arranged in a standard pattern up the pole to act as hand and foot holds so that maintenance and repair workers can climb the pole to work on the lines. In the United States, such steps have been determined to be a public hazard and are no longer allowed on new poles.{{citation needed|date=September 2012}} Linemen may use climbing spikes called gaffs to ascend wooden poles without steps on them. In the UK, boots fitted with steel loops that go around the pole (known as "Scandinavian Climbers") are also used for climbing poles. In the US, linemen use [[Cherry picker|bucket trucks]] for the vast majority of poles that are accessible by vehicle. ==Dead-end poles== {{unreferenced section|date=August 2012}} [[File:Dead end riser poles.jpg|thumb|upright|right|Example of dead-end riser poles]] The poles at the end of a straight section of utility line where the line ends or angles off in another direction are called ''dead-end'' poles in the United States. Elsewhere they may be referred to as anchor or termination poles. These must carry the lateral [[tension (physics)|tension]] of the long straight sections of wire. They are usually made with heavier construction. The power lines are attached to the pole by horizontal strain insulators, either placed on crossarms (which are either doubled, tripled, or replaced with a steel crossarm, to provide more resistance to the tension forces) or attached directly to the pole itself. Dead-end and other poles that support lateral loads have [[guy-wires]] to support them. The guys always have [[strain insulator]]s inserted in their length to prevent any high voltages caused by electrical faults from reaching the lower portion of the cable that is accessible by the public. In populated areas, guy wires are often encased in a yellow plastic or wood tube with reflectors attached to their lower end, so that they can be seen more easily, reducing the chance of people and animals walking into them or vehicles crashing into them. Another means of providing support for lateral loads is a push brace pole, a second shorter pole that is attached to the side of the first and runs at an angle to the ground. If there is no space for a lateral support, a stronger pole, e.g. a construction of concrete or iron, is used. {{Clear}} ==History== [[File:Hakodate-Concrete-Utility-Pole.jpg|thumb|From 1923, the oldest utility pole in Japan, still in use in the city of Hakodate.]] [[File:Art work of Toledo, Ohio - DPLA - 0a107364e8d8eb430ebc183d28c46463 (page 107) (cropped).jpg|thumb|right|Utility poles seen outside the Gardner Building, in [[Toledo, Ohio]], 1895]] The system of suspending telegraph wires from poles with ceramic insulators was invented and patented by British telegraph pioneer [[William Fothergill Cooke]]. Cooke was the driving force in establishing the [[electrical telegraph]] on a commercial basis. With [[Charles Wheatstone]] he invented the [[Cooke and Wheatstone telegraph]] and founded the world's first telegraph company, the [[Electric Telegraph Company]]. Telegraph poles were first used on the [[Great Western Railway]] in 1843 when the Cooke and Wheatstone telegraph line was extended to [[Slough]]. The line had previously used buried cables but that system had proved troublesome with failing insulation.<ref name=Kieve>Kieve, Jeffrey L., ''The Electric Telegraph: A Social and Economic History'', David and Charles, 1973 {{oclc|655205099}}.</ref>{{rp|32}} In Britain, the trees used for telegraph poles were either native [[larch]] or [[pine]] from Sweden and Norway. Poles in early installations were treated with tar, but these were found to last only around seven years. Later poles were treated instead with [[creosote]] or [[copper sulphate]] for the preservative.<ref name=Kieve/>{{rp|80}} Utility poles were first used in the mid-19th century in [[United States|America]] with telegraph systems. In 1844, the [[United States Congress]] granted [[Samuel Morse]] $30,000 ({{Inflation|US|30000|1844|fmt=eq|r=-2}}) to build a 40-mile [[telegraph]] line between [[Baltimore]], [[Maryland]] and [[Washington, D.C.]] Morse began by having a lead-sheathed cable made. After laying {{convert|7| miles||spell=in}} underground, he tested it. He found so many faults with this system that he dug up his cable, stripped off its sheath, bought poles and strung his wires overhead. On February 7, 1844, Morse inserted the following advertisement in the Washington newspaper: "Sealed proposals will be received by the undersigned for furnishing 700 straight and sound chestnut posts with the bark on and of the following dimensions to wit: 'Each post must not be less than eight inches in diameter at the butt and tapering to five or six inches at the top. Six hundred and eighty of said posts to be 24 feet in length, and 20 of them 30 feet in length.'" In some parts of Australia, wooden poles are rapidly destroyed by [[termite]]s, so metal poles must be used instead and in much of the interior wooden poles are vulnerable to fire. The [[Oppenheimer pole]] is a collapsible [[wrought iron]] pole in three sections. It is named after Oppenheimer and Company in Germany, but they were mostly manufactured in England under license.<ref>[https://www.engineersaustralia.org.au/sites/default/files/HRP.Overland%20Telegraqph%20Joining%20Point ''Nomination for Engineering Heritage Recognition: The Overland Telegraph Line 'Joining Point', Frews Pond, Northern Territory''] {{Webarchive|url=https://web.archive.org/web/20140911194134/https://www.engineersaustralia.org.au/sites/default/files/HRP.Overland%20Telegraqph%20Joining%20Point |date=2014-09-11 }}, [[Engineers Australia]], June 2012.</ref> They were used on the [[Australian Overland Telegraph Line]] built in 1872 which connected the continent north to south directly through the centre and linked to the rest of the world through a [[submarine communications cable|submarine cable]] at [[Darwin, Australia|Darwin]].<ref>McMullen, Ron, "The Overland Telegraph", [http://w1tp.com/mron.htm ''The Australian Telegraph Office''] (CD ROM).</ref> The Stobie pole was invented in 1924 by James Cyril Stobie of the [[Adelaide Electric Supply Company]] and first used in [[South Terrace, Adelaide]].<ref>Rob Linn, ''ETSA – The Story of Electricity in South Australia'', pp. 38–39, 1996.</ref> One of the early [[Bell System]] lines was the Washington DC–Norfolk line which was, for the most part, square-sawn tapered poles of [[List of Pinus species|yellow pine]] probably treated to refusal with [[creosote]]. "Treated to refusal" means that the manufacturer forces preservatives into the wood, until it refuses to accept more, but performance is not guaranteed.<ref>{{cite web |publisher = Western Wood Preserver's Institute |url = http://www.wwpinstitute.org/documents/TreatedtoRefusalAlert.pdf |title = "Treated to refusal" does not meet the requirements of the international building codes |access-date = October 13, 2016 |url-status = live |archive-url = https://web.archive.org/web/20160812152017/http://wwpinstitute.org/documents/TreatedtoRefusalAlert.pdf |archive-date = August 12, 2016 }}</ref> Some of these were still in service after 80 years.<ref>{{cite web|publisher=American Wood Preservers' Association|year=1978|url=http://www.pmcpole.com/cms/AWPA_poleMaintenance_paper.pdf|title=Pole Maintenance-Its Need and Its Effectiveness|author=James A. Taylor Timber Products Specialist Rural Electrification Administration U.S. Department of Agriculture Washington, D.C.|url-status=live|archive-url=https://web.archive.org/web/20110715094205/http://www.pmcpole.com/cms/AWPA_poleMaintenance_paper.pdf|archive-date=2011-07-15}}</ref> The building of pole lines was resisted in some urban areas in the late 19th century,{{citation needed|date=August 2021}} and political pressure for [[undergrounding]] remains powerful in many countries. In [[Eastern Europe]], Russia, and third-world countries, many utility poles still carry bare communication wires mounted on insulators not only along railway lines, but also along roads and sometimes even in urban areas. Errant traffic being uncommon on railways, their poles are usually less tall. In the United States electricity is predominately carried on unshielded [[aluminium|aluminum]] conductors wound around a solid steel core and affixed to rated insulators made from glass, ceramic, or poly. Telephone, CATV, and FOCs are generally attached directly to the pole without insulators. In the United Kingdom, much of the rural electricity distribution system is carried on wooden poles. These normally carry electricity at 11 or 33 kV (three phases) from 132 kV substations supplied from [[Transmission tower|pylons]] to distribution substations or pole-mounted transformers. Wooden poles have been used for 132 kV for a number of years from the early 1980s one is called the trident they are usually used on short sections, though the line from Melbourne, Cambs to near Buntingford, Herts is quite long. The conductors on these are bare metal connected to the posts by insulators. Wood poles can also be used for [[low voltage]] distribution to customers. [[File:Upoles ottawa.jpg|left|thumb|Poles in [[Ottawa, Ontario]], Canada]] Today, utility poles may hold much more than the uninsulated copper wire that they originally supported. Thicker cables holding many [[twisted pair]], [[coaxial cable]], or even [[fibre-optic]], may be carried. Simple analogue [[repeater]]s or other [[outside plant]] equipment have long been mounted against poles, and often new digital equipment for [[multiplexing]]/demultiplexing or digital repeaters may now be seen. In many places, as seen in the illustration, providers of electricity, television, telephone, street light, traffic signal and other services share poles, either in joint ownership or by renting space to each other. In the United States, ANSI standard 05.1.2008<ref>[http://www.fpl.fs.fed.us/documnts/pdf1997/wolfe97b.pdf Standard specifications for wood poles] {{webarchive|url=https://web.archive.org/web/20120224031935/http://www.fpl.fs.fed.us/documnts/pdf1997/wolfe97b.pdf |date=2012-02-24 }} US Department of Agriculture, Forest Products Laboratory</ref> governs wood pole sizes and strength loading. Utilities that fall under the [[Rural Electrification Act]] must also follow the guidelines set forth in RUS Bulletin 1724E-150<ref>{{cite web |url=http://www.usda.gov/rus/electric/bulletins.htm |title=USDA Rural Development's Electric Programs - Bulletins |access-date=2009-01-02 |url-status=dead |archive-url=https://web.archive.org/web/20090115194247/http://www.usda.gov/rus/electric/bulletins.htm |archive-date=2009-01-15 }}</ref> (from the US Department of Agriculture) for pole strength and loading. Steel utility poles are becoming more prevalent in the United States thanks to improvements in engineering and corrosion prevention coupled with lowered production costs. However, premature failure due to corrosion is a concern when compared to wood.<ref>{{cite web|url=http://www.pmcpole.com/cms/CorrosionManagementDocument.pdf|title=PMCPOLE.COM|website=www.pmcpole.com|url-status=live|archive-url=https://web.archive.org/web/20090114191250/http://www.pmcpole.com/cms/CorrosionManagementDocument.pdf|archive-date=2009-01-14}}</ref> [http://www.NACE.org The National Association of Corrosion Engineers] {{Webarchive|url=https://web.archive.org/web/20100619154509/http://nace.org/content.cfm?parentid=1020¤tID=1132 |date=2010-06-19 }} or NACE is developing inspection, maintenance, and prevention procedures similar to those used on wood utility poles to identify and prevent decay. ==Markings== ===Pole brandings=== [[File:UK-BT-telegraph-post.png|right|thumb|Markings on a BT post]] [[British Telecom]] posts are usually marked with the following information:{{citation needed|date=November 2010}} {{Incomplete list|date=August 2008}} * 'BT' – to mark it as a [[British Telecom]] UK Pole (This can also be PO (Post Office) or GPO (General Post Office) depending on the age of the pole) * a horizontal line marking 3 metres from the bottom of the pole * the pole length, typically 8 to 10 metres,<ref>David Chambers, [https://www.thinksmallcell.com/Metrocells/every-telegraph-pole-across-uk-now-a-potential-outdoor-small-cell-site.html "Every telegraph pole across UK now a potential outdoor small cell site"] {{Webarchive|url=https://web.archive.org/web/20220123110726/https://www.thinksmallcell.com/Metrocells/every-telegraph-pole-across-uk-now-a-potential-outdoor-small-cell-site.html |date=2022-01-23 }}, ''ThinkSmallCell'', 23 October 2014.</ref> and size. 9L is a 9 metres long, light pole, other letters used are 'M' (Medium) and 'S' (Stout). * the year of treatment and therefore generally the year of installation (e.g. the pole in the picture was treated in 2003) * the batch and type of wood used * A date of the last official inspection * An alphanumeric designation e.g. DP 242 where DP is an initialism of Distribution Point * If relevant, a red D plate meaning 'Dangerous' and indicating that the pole was structurally unsafe to climb or due to its proximity to other hazards<ref>{{Cite web|url=http://www.britishtelephones.com/gpo/pole.htm|title=GPO / British Telecom Telephone poles|date=2011-10-29|website=www.britishtelephones.com|access-date=2016-11-27|url-status=live|archive-url=https://web.archive.org/web/20170424132211/http://www.britishtelephones.com/gpo/pole.htm|archive-date=2017-04-24}}</ref> The date on the pole is applied by the manufacturer and refers to the date the pole was "preserved" (treated to withstand the elements). [[Image:Pole Brand Salisbury MD.jpg|left|thumb|Brandings on a pole in [[Salisbury, Maryland]], United States]] In the United States, utility poles are marked with information concerning the manufacturer, pole height, ANSI strength class, wood species, original preservative, and year manufactured<ref>{{cite web|url=http://www.pmcpole.com/cms/AWPAPoleBrands.pdf|title=PMCPOLE.COM|website=www.pmcpole.com|url-status=live|archive-url=https://web.archive.org/web/20090114191301/http://www.pmcpole.com/cms/AWPAPoleBrands.pdf|archive-date=2009-01-14}}</ref> (vintage) in accordance with ANSI standard O5.1.2008.<ref>{{cite web|url=http://www.ansi.org/|title=ANSI-American National Standards Institute|website=www.ansi.org|url-status=live|archive-url=https://web.archive.org/web/20080828024250/http://www.ansi.org./|archive-date=2008-08-28}}</ref> This is called branding, as it is usually burned into the surface; the resulting mark is sometimes called the "birth mark". Although the position of the brand is determined by ANSI specification, it is essentially just below "eye level" after installation. A rule of thumb for understanding a pole's brand is the manufacturer's name or logo at the top with a two-digit date beneath (sometimes preceded by a month). Below the date is a two-character wood species abbreviation and one- to three-character preservative. Some wood species may be marked "SP" for southern pine, "WC" for western cedar, or "DF" for Douglas fir. Common preservative abbreviations are "C" for [[creosote]], "P" for [[pentachlorophenol]], and "SK" for [[chromated copper arsenate]] (originally referred to salts type K). The next line of the brand is usually the pole's ANSI class, used to determine maximum load; this number ranges from 10 to H6 with a smaller number meaning higher strength. The pole's height (from butt to top) in 5-foot increments is usually to the right of the class separated by a hyphen, although it is not uncommon for older brands to have the height on a separate line. The pole brand is sometimes an aluminum tag nailed in place. Before the practice of branding, many utilities would set a 2- to 4-digit [[Datenail|date nail]] into the pole upon installation. The use of date nails went out of favor during World War II due to war shortages but is still used by a few utilities. These nails are considered valuable to collectors, with older dates being more valuable, and unique markings such as the utilities' name also increasing the value. However, regardless of the value to collectors, all attachments on a utility pole are the property of the utility company, and unauthorized removal is a misdemeanor or felony.<ref>{{Cite web|url=http://leginfo.legislature.ca.gov/faces/codes_displaySection.xhtml?lawCode=PEN§ionNum=591.|title=Malicious Injuries to Railroad Bridges, Highways, Bridges, and Telegraphs|website=leginfo.legislature.ca.gov|access-date=2019-10-11}}</ref> <sup>(California state law cited as example)</sup> ===Coordinates on pole tags=== A practice in some areas is to place poles on coordinates upon a grid. The pole at right is a [[Delmarva Power]] pole located in a rural area of the state of [[Maryland]] in the United States. The lower two tags are the "X" and "Y" coordinates along said grid. Just as in a [[Cartesian coordinate system|coordinate plane]] used in geometry, X increases as one travels east and Y increases as one travels north. The upper two tags are specific to the sub transmission section of the pole; the first refers to the route number, the second to the specific pole along the route. However, not all power lines follow the road. In the British region of [[East Anglia]], [[EDF Energy]] Networks often add the [[Ordnance Survey]] Grid Reference coordinates of the pole or substation to the name sign. In some areas, utility pole name plates may provide valuable coordinate information: a poor man's [[GPS]].<ref>{{cite web|url=http://wiki.osgeo.org/wiki/Taiwan_Power_Company_grid|title=Taiwan Power Company grid – OSGeo|website=wiki.osgeo.org|url-status=live|archive-url=https://web.archive.org/web/20081211080807/http://wiki.osgeo.org/wiki/Taiwan_Power_Company_grid|archive-date=2008-12-11}}</ref><ref>{{cite web|url=http://jidanni.org/geo/taipower/index.html|title=Understanding coordinates on utility pole numbers|url-status=live|archive-url=https://web.archive.org/web/20070927230026/http://jidanni.org/geo/taipower/index.html|archive-date=2007-09-27}} A [[Taiwan Power Company]] example; [[:zh:電力座標]]</ref><ref>{{cite web|url= http://www.zoklet.net/totse/en/technology/science_technology/readpole.html|title= How to read those little metal plates on Hydro pol|url-status=live|archive-url= https://web.archive.org/web/20130605221139/http://www.zoklet.net/totse/en/technology/science_technology/readpole.html|archive-date= 2013-06-05}} A [[British Columbia]], Canada example;</ref> <gallery mode="packed" heights="200px"y> File:Pole Tag Crisfield MD USA.jpg|The tags on a [[Delmarva Power]] subtransmission pole located in [[Crisfield, Maryland]], United States. The faded tag reads "733" File:Newpole2.jpg|A utility pole replacement in Saugus, Massachusetts, United States File:Utility pole tags.jpg|Tag and marking on the bottom of a wooden utility pole before it is installed </gallery> == Pole route == [[File:Pole Route.jpg|thumb|Telegraph pole with spars, insulators and open wires on a now decommissioned Railway Pole Route, Eccles Road, [[Norfolk]], United Kingdom]] A '''pole route''' (or '''pole line''' in the US) is a telephone link or electrical power line between two or more locations by way of multiple uninsulated wires suspended between wooden utility poles. This method of link is common especially in rural areas where burying the cables would be expensive. Another situation in which pole routes were extensively used were on the railways to link [[signal boxes]]. Traditionally, prior to around 1965, pole routes were built with open wires along non-electrical operated railways; this necessitated insulation when the wire passed over the pole, thus preventing the signal from becoming attenuated. At electrical operated railways, pole routes were usually not built as too much jamming from the overhead wire would occur. To accomplish this, cables were separated using spars with insulators spaced along them; in general four insulators were used per spar. Only one such pole route still exists on the UK rail network, in the highlands of Scotland. There was also a long section in place between [[Wymondham]], [[Norfolk]] and [[Brandon, Suffolk|Brandon]] in [[Suffolk]], United Kingdom; however, this was de-wired and removed during March 2009. [[File:Country Crossing - geograph.org.uk - 568823.jpg|thumb|A railway telegraph pole beside a railway bridge on the former [[Portadown, Dungannon and Omagh Junction Railway|railway line]] between [[Portadown railway station|Portadown]] and [[Dungannon railway station|Dungannon]] in Northern Ireland.]] ==Environmental impact== {{expand section|date=August 2012}} [[File:Cigognes Vladeni Roumanie.jpg|thumb|[[White stork]]s (''Ciconia ciconia'') in their nest on a utility pole in rural Romania]] Utility poles are used by birds for nesting and to rest on.<ref>{{Cite web |title=Bird Nests on Power Poles |url=https://www.aplic.org/Nests |access-date=2024-02-21 |website=www.aplic.org}}</ref><ref>{{Cite web |title=Why Do Birds Sit On Power Lines? (Everything Explained) |url=https://birdfact.com/articles/why-do-birds-sit-on-power-lines |access-date=2024-02-21 |website=Birdfact |language=en}}</ref> Utility poles and related structures are regarded by some to be a form of [[visual pollution]]{{Citation needed|date=February 2024}}. Many lines are [[Undergrounding|placed underground]] for this reason, in places of high population density or scenic beauty that justify the expense. Architects design some pylons to be pretty, thus avoiding visual pollution{{Citation needed|date=February 2024}}. Some chemicals used to preserve wood poles including [[creosote]] and [[pentachlorophenol]] are toxic and have been found in the environment{{Citation needed|date=February 2024}}. The considerable improvement in weathering resistance offered by creosote infusion has long-term drawbacks. In recent years, concerns have been raised about the toxicity of creosote-treated wood waste, such as utility poles. Specifically, their biodegradation can release phenolic compounds in soil, which are considered toxic. Research continues to explore methods to render this waste safe for disposal.<ref>{{cite journal |last1=Mateus |first1=E. |last2=Zrostlikova |first2=J. |last3=Gomes da Silva |first3=M.D.R |last4=Ribeiro |first4=A. |last5=Marriott |first5=P. |title=Electrokinetic removal of creosote from treated timber waste: a comprehensive gas chromatographic view |journal=Journal of Applied Electrochemistry |date=2010 |volume=40 |issue=6 |pages=1183–1193 |doi=10.1007/s10800-010-0089-7 |s2cid=97862454 }}</ref> Historically, pole-mounted transformers were filled with a [[polychlorinated biphenyl]] (PCB) liquid. PCBs persist in the environment and have adverse effects on animals. ==See also== {{Portal|Electronics|Telecommunications}} {{div col|colwidth=23em}} * [[Caber toss]], a sport involving the throwing of large poles. * [[Charging station]] * [[Fence]] post * [[Lamppost]] * [[Oppenheimer pole]] * [[Public utility]] * [[Stanchion]] * [[Stobie pole]] * [[Traction current pylon]] * [[Transmission tower|High voltage electricity pylon]] {{div col end}} ==References== {{reflist|2}} ==External links== {{Commons category|Utility poles|Utility pole}} * [http://www.telegraphpoleappreciationsociety.org/ The Telegraph Pole Appreciation Society] * [http://www.elp.com/index/display/article-display/279131/articles/utility-automation-engineering-td/volume-11/issue-10/features/getting-equipped-utility-poles.html Article on Utility-Telecom Joint Use of Poles] * [http://www.photovault.com/Link/Industry/Construction/ElectricTelephone/ICEVolume01.html Many photographs] {{Webarchive|url=https://web.archive.org/web/20160807091957/http://www.photovault.com/Link/Industry/Construction/ElectricTelephone/ICEVolume01.html |date=2016-08-07 }} * [http://troyb.net/portfolio/poles.html Photographs of Various U.S. Utility Poles] * [http://myinsulators.com/hungary Hungarian Telephone Poles] * [http://www.annsgarden.com/poles/poles.htm Utility Poles @ Ann's Garden] * [http://www.pmcpole.com/documents/inspection/methods.aspx Wood Utility Pole Inspection Methods] {{Webarchive|url=https://web.archive.org/web/20160304074115/http://www.pmcpole.com/documents/inspection/methods.aspx |date=2016-03-04 }} * [http://www.myinsulators.com/ukinsulators/pole.htm A photo collection of pole routes throughout the UK and abroad] * [http://www.AWPA.com American Wood Protection Association] * [http://www.usda.gov/rus/electric/ USDA Rural Development's Electric Programs] {{Webarchive|url=https://web.archive.org/web/20121016044234/http://www.usda.gov/rus/electric/ |date=2012-10-16 }} * [http://telecom-info.njdepot.ericsson.net/site-cgi/ido/docs.cgi?ID=SEARCH&DOCUMENT=GR-60& GR-60, ''Generic Requirements for Wooden Utility Poles''] {{Electricity delivery}} {{Wood products}} {{Authority control}} {{DEFAULTSORT:Utility Pole}} [[Category:Electric power distribution]] [[Category:Street furniture]] [[Category:Pylons]] [[Category:Electric power infrastructure]] [[Category:Telephony equipment]] [[Category:Telecommunications equipment]] [[Category:Telecommunications infrastructure]] [[Category:Articles containing video clips]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Ambox
(
edit
)
Template:Authority control
(
edit
)
Template:Citation needed
(
edit
)
Template:Cite book
(
edit
)
Template:Cite journal
(
edit
)
Template:Cite web
(
edit
)
Template:Clear
(
edit
)
Template:Commons category
(
edit
)
Template:Convert
(
edit
)
Template:Cvt
(
edit
)
Template:Div col
(
edit
)
Template:Div col end
(
edit
)
Template:Electricity delivery
(
edit
)
Template:Expand section
(
edit
)
Template:Incomplete list
(
edit
)
Template:Inflation
(
edit
)
Template:Main other
(
edit
)
Template:Oclc
(
edit
)
Template:Portal
(
edit
)
Template:Reflist
(
edit
)
Template:Rp
(
edit
)
Template:Short description
(
edit
)
Template:Sister project
(
edit
)
Template:Unreferenced section
(
edit
)
Template:Use dmy dates
(
edit
)
Template:Vanchor
(
edit
)
Template:Webarchive
(
edit
)
Template:Wood products
(
edit
)