Open main menu
Home
Random
Recent changes
Special pages
Community portal
Preferences
About Wikipedia
Disclaimers
Incubator escapee wiki
Search
User menu
Talk
Dark mode
Contributions
Create account
Log in
Editing
Voltmeter
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{{Short description|Instrument used for measuring voltage}} {{distinguish|Voltameter}} {{Multiple issues| {{ref improve|date=April 2009}} {{Sources exist|date=February 2024}} }} [[Image:Voltmeter hg.jpg|thumb|Demonstration analog voltmeter]] A '''voltmeter''' is an instrument used for measuring [[electric potential]] difference between two points in an [[electric circuit]]. It is connected in [[Parallel circuit|parallel]]. It usually has a high [[Electrical resistivity and conductivity|resistance]] so that it takes negligible current from the circuit. Analog voltmeters move a pointer across a scale in proportion to the voltage measured and can be built from a [[galvanometer]] and series [[resistor]]. Meters using [[amplifier]]s can measure tiny voltages of microvolts or less. Digital voltmeters give a numerical display of voltage by use of an [[analog-to-digital converter]]. Voltmeters are made in a wide range of styles, some separately powered (e.g. by battery), and others powered by the measured voltage source itself. Instruments permanently mounted in a panel are used to monitor generators or other fixed apparatus. Portable instruments, usually equipped to also measure current and resistance in the form of a [[multimeter]] are standard test instruments used in electrical and electronics work. Any measurement that can be converted to a voltage can be displayed on a meter that is suitably calibrated; for example, pressure, temperature, flow or level in a chemical process plant. General-purpose analog voltmeters may have an accuracy of a few percent of full scale and are used with voltages from a fraction of a volt to several thousand volts. Digital meters can be made with high accuracy, typically better than 1%. Specially calibrated test instruments have higher accuracies, with laboratory instruments capable of measuring to accuracies of a few parts per million. Part of the problem of making an accurate voltmeter is that of calibration to check its accuracy. In laboratories, the [[Weston cell]] is used as a standard voltage for precision work. Precision voltage references are available based on electronic circuits. ==Schematic symbol== [[File:Symbole voltmetre.png|thumb|Voltmeter symbol]] In circuit diagrams, a voltmeter is represented by the letter ''V'' in a circle, with two emerging lines representing the two points of measurement.{{clear}} ==Analog voltmeter== [[Image:Galvanometer diagram.svg|thumb|A moving coil [[galvanometer]] of the [[d'Arsonval]] type. {{unordered list | The red wire carries the current to be measured. | The restoring spring is shown in green. | N and S are the north and south poles of the magnet.}}]] A moving coil [[galvanometer]] can be used as a voltmeter by inserting a [[resistor]] in [[series circuit|series]] with the instrument. The galvanometer has a coil of fine wire suspended in a strong magnetic field. When an electric current is applied, the interaction of the magnetic field of the coil and of the stationary magnet creates a torque, tending to make the coil rotate. The torque is proportional to the current through the coil. The coil rotates, compressing a spring that opposes the rotation. The deflection of the coil is thus proportional to the current, which in turn is proportional to the applied voltage, which is indicated by a pointer on a scale. One of the design objectives of the instrument is to disturb the circuit as little as possible and so the instrument should draw a minimum of current to operate. This is achieved by using a sensitive galvanometer in series with a high resistance, and then the entire instrument is connected in parallel with the circuit examined. The sensitivity of such a meter can be expressed as "ohms per volt", the number of ohms resistance in the meter circuit divided by the full scale measured value. For example, a meter with a sensitivity of 1000 ohms per volt would draw 1 milliampere at full scale voltage; if the full scale was 200 volts, the resistance at the instrument's terminals would be {{val|200000}} ohms and at full scale, the meter would draw 1 milliampere from the circuit under test. For multi-range instruments, the input resistance varies as the instrument is switched to different ranges. Moving-coil instruments with a permanent-magnet field respond only to direct current. Measurement of AC voltage requires a [[rectifier]] in the circuit so that the coil deflects in only one direction. Some moving-coil instruments are also made with the zero position in the middle of the scale instead of at one end; these are useful if the voltage reverses its polarity. Voltmeters operating on the [[Electrostatic voltmeter|electrostatic principle]] use the mutual repulsion between two charged plates to deflect a pointer attached to a spring. Meters of this type draw negligible current but are sensitive to voltages over about 100 volts and work with either alternating or direct current. == Amplified voltmeter == The sensitivity and input resistance of a voltmeter can be increased if the current required to deflect the meter pointer is supplied by an amplifier and power supply instead of by the circuit under test. The electronic amplifier between input and meter gives two benefits; a rugged moving coil instrument can be used, since its sensitivity need not be high, and the input resistance can be made high, reducing the current drawn from the circuit under test. Amplified voltmeters often have an input resistance of 1, 10, or 20 megohms which is independent of the range selected. A once-popular form of this instrument used a vacuum tube in the amplifier circuit and so was called the vacuum tube voltmeter (VTVM). These were almost always powered by the local AC line current and so were not particularly portable. Today these circuits use a solid-state amplifier using [[field-effect transistor]]s, hence FET-VM, and appear in handheld [[multimeter|digital multimeters]] as well as in bench and laboratory instruments. These largely replaced non-amplified multimeters except in the least expensive price ranges. Most VTVMs and FET-VMs handle DC voltage, AC voltage, and resistance measurements; modern FET-VMs add current measurements and often other functions as well. A specialized form of the VTVM or FET-VM is the AC voltmeter. These instruments are optimized for measuring AC voltage. They have much wider bandwidth and better sensitivity than a typical multifunction device. == Digital voltmeter == [[Image:Voltmeter.jpg|thumb|right|200px|Two digital voltmeters. Note the 40 microvolt difference between the two [[measurement]]s, an offset of 34 parts per million.]] A '''digital voltmeter''' (DVM) measures an unknown input voltage by converting the voltage to a digital value and then displays the voltage in numeric form. DVMs are usually designed around a special type of [[analog-to-digital converter]] called an [[Integrating ADC|integrating converter]]. DVM measurement accuracy is affected by many factors, including temperature, input impedance, and DVM power supply voltage variations. Less expensive DVMs often have input resistance on the order of 10 MΞ©. Precision DVMs can have input resistances of 1 GΞ© or higher for the lower voltage ranges (e.g. less than 20 V). To ensure that a DVM's accuracy is within the manufacturer's specified tolerances, it must be periodically calibrated against a [[Voltage reference|voltage standard]] such as the [[Weston cell]]. The first digital voltmeter was invented and produced by [[Andrew Kay]] of Non-Linear Systems (and later founder of [[Kaypro]]) in 1954.<ref name="Andrew Kay Obituary by John Markoff ">{{cite web | url=https://www.nytimes.com/2014/09/06/business/andrew-kay-pioneer-in-computing-dies-at-95.html | title=Andrew Kay, Pioneer in Computing, Dies at 95 | publisher=New York Times | work=Obituary | date=5 Sep 2014 | access-date=7 September 2014 | author=Markoff, John}}</ref> Simple AC voltmeters use a rectifier connected to a DC measurement circuit, which responds to the average value of the waveform. The meter can be calibrated to display the [[root mean square]] value of the waveform, assuming a fixed relation between the average value of the rectified waveform and the RMS value. If the waveform departs significantly from the sinewave assumed in the calibration, the meter will be inaccurate, though for simple wave shapes the reading can be corrected by multiplying by a constant factor. Early "true RMS" circuits used a thermal converter that responded only to the RMS value of the waveform. Modern instruments calculate the RMS value by electronically calculating the square of the input value, taking the average, and then calculating the square root of the value. This allows accurate RMS measurements for a variety of waveforms.<ref>{{Cite web |date=2021-06-21 |title=What is RMS Voltage |url=https://www.electrical4u.com/rms-or-root-mean-square-value-of-ac-signal/ |access-date=2023-04-23 |website=Electrical4U |language=en-US}}</ref> ==References== {{Reflist}} ==External links== {{commons category|Voltmeters}} * [http://www.ibiblio.org/kuphaldt/electricCircuits/DC/DC_8.html ''DC Metering Circuits''] chapter from [http://www.ibiblio.org/kuphaldt/electricCircuits/DC/index.html ''Lessons In Electric Circuits Vol 1 DC''] free ebook and [http://www.ibiblio.org/kuphaldt/electricCircuits/ ''Lessons In Electric Circuits''] series. {{Electrical and electronic measuring equipment}} {{Authority control}} [[Category:Electrical meters]] [[Category:Measuring instruments]] [[Category:Electronic test equipment]] [[Category:Voltmeters| ]]
Edit summary
(Briefly describe your changes)
By publishing changes, you agree to the
Terms of Use
, and you irrevocably agree to release your contribution under the
CC BY-SA 4.0 License
and the
GFDL
. You agree that a hyperlink or URL is sufficient attribution under the Creative Commons license.
Cancel
Editing help
(opens in new window)
Pages transcluded onto the current version of this page
(
help
)
:
Template:Authority control
(
edit
)
Template:Cite web
(
edit
)
Template:Clear
(
edit
)
Template:Commons category
(
edit
)
Template:Distinguish
(
edit
)
Template:Electrical and electronic measuring equipment
(
edit
)
Template:Multiple issues
(
edit
)
Template:Reflist
(
edit
)
Template:Short description
(
edit
)
Template:Sister project
(
edit
)
Template:Unordered list
(
edit
)
Template:Val
(
edit
)